SIEMENS 6AV6645-0BB01-0AX0

  • EICHLER-art.no.: K0170450
  • EAN: 4025515089766
  • UPC: 662643397031

Product description

SIMATIC MOBILE PANEL 177 PN WITH INTEGRATED ACKNOWLEDGMENT BUTTON AND STOP PUSHBUTTON, CONFIGURABLE WITH WINCC FLEXIBLE COMPACT VERSION 2005 OR HIGHER OR TIA PORTAL V11 TO V14

Services for SIEMENS 6AV6645-0BB01-0AX0

Repair

1-3 days

from 1.509,38 €

to 2.716,88 €

per pc. 159,00 €

Replacement

1-3 days

9 Pcs.

3.646,80 €

per pc. 159,00 €

3.646,80 € *

Please enter an offer recipient here.


Used

1-3 days

9 Pcs.

4.052,00 €

per pc. 159,00 €

4.052,00 € *

Please enter an offer recipient here.


New

Delivery information
Export identifier AL: N ECCN: 5D992
Net weight 1.624
Quantity 1 Stück
Packaging quantity 1
Additional product information
Product status EOP: 2021-10-01
EAN 4025515089766
UPC 662643397031
Static lot number 85371098
List indicator ST80.1E
Product group 4367
Country of origin AT
Compliance with the substance restrictions according to RoHS directive Since: 20100101
Product classifications Version Classification
eClass 4 27-36-01-02
eClass 5.1 27-24-23-03
eClass 6.0 27-24-23-03
ETIM 3 /
ETIM 4 EC001427
ETIM 5 EC001427

What is 6AV6645-0BB01-0AX0 and where is it used?

The SIEMENS 6AV6645-0BB01-0AX0 is a SIMATIC Mobile Panel 177 PN designed for mobile operation and monitoring tasks directly on machines and systems. The device combines a 5.7-inch display with both keypad and touch operation as well as an integrated enabling switch and stop button. This makes it particularly suitable for production environments where operators work close to the machine, support setup procedures or locally enable axis movements and machine functions. The panel is supplied via a connection box; for the PN version, operation with the Connection Box PN and Connecting Cable PN is relevant. Typical applications include packaging machinery, special-purpose machine construction, handling systems, robotic cells and maintenance service operations.

Overview of the key technical data and what they mean

From a technical perspective, the Mobile Panel 177 PN features a 5.7-inch STN colour display with 320 × 240 pixels and 256 colours. For operation, it provides 14 function keys, 8 of which include LEDs, as well as numeric, alphanumeric and hexadecimal input options and an analogue resistive touchscreen. Communication interfaces include 1 × Ethernet RJ45 and 1 × RS485; supported protocols include PROFINET IO, TCP/IP and Modbus. The device runs on Windows CE, is powered via the connection box and is designed for safety functions up to Performance Level d (PL d) according to ISO 13849-1. Additional features important for industrial operation include a maximum drop height of 1.5 m, an operating temperature range of 0 to 40 °C and a backlight with an MTBF of 50,000 hours.

Product status, life-cycle status and obsolescence

The product status is particularly important for procurement. Siemens classifies 6AV6645-0BB01-0AX0 as a spare part, while the EICHLER product page additionally lists the status EOP: 2021-10-01. Siemens published the discontinuation announcement for the Mobile Panel 177/277 family and the associated connection boxes on 25 April 2016 and explicitly recommends the Mobile Panels 2nd Generation as the successor platform for new machines. The available sources do not identify a direct 1:1 successor article number for this specific MLFB, but they do identify the compatible successor platform. For modernisation projects, it is important to note that the Mobile Panel 177 is no longer supported from TIA Portal V16 onwards. Furthermore, when used with connection boxes of the 2nd Generation, only a hard-wired F-system is permitted; PROFIsafe is not supported with the 1st Generation platform.

Available EICHLER services and when they are relevant

For maintenance and purchasing departments, EICHLER’s services are particularly valuable for obsolete HMI devices. Repair, exchange, used equipment and new-unit enquiries cover a wide range of procurement scenarios. If a panel fails, repair is often the fastest way to continue operating existing engineered equipment; EICHLER specifies a turnaround time of 1–3 days and includes technical cleaning, preventive maintenance, comprehensive functional testing and a minimum 24-month warranty. Where downtime costs exceed repair times, exchange units become particularly attractive; at the time of review, exchange and used units were also listed with 1–3 day availability and stock levels. The optional test report supports documentation, acceptance procedures and internal quality assurance. For industrial operators, this combination helps maintain operational capability despite obsolescence and reduces the risk of unplanned downtime.

Attribute Value
Product type designation Mobile Panel 177 PN
Display
Design of display STN
Screen diagonal 5.7 in
Color display Yes
Number of colors 256
Resolution (pixels)
● Horizontal image resolution 320 pixel
● Vertical image resolution 240 pixel
Backlighting
● MTBF backlighting (at 25 °C) 50 000 h
● Backlight dimmable No
Control elements
Control elements Keys and touch
Keyboard fonts
● Membrane keyboard
— user-definable label membrane keys Yes
● Function keys
— Number of function keys 14
— Number of function keys with LEDs 8
● Keys with LED Yes; 8 with LED
● Numeric keyboard Yes
● alphanumeric keyboard Yes
● hexadecimal keyboard Yes
● Multi-key operation Yes
— Number of multi-key operations 2
Touch operation
● Design as touch screen Yes; analog, resistive
Special operator controls
● Stop button Yes
● Acknowledgement button Yes
● Key-operated switch No
● Illuminated pushbutton No
● Handwheel No
Supply voltage
Design of the power supply via connection box
Type of supply voltage DC
Processor
Processor type RISC 32 bit, 200 MHz
Memory
Type of memory Flash / RAM
Memory available for user data 2 048 kbyte
Accumulator
Buffer battery Yes; maximum buffer time 10 min
Type of output
Info LED No
Power LED No
Error LED No
Interfaces
Interfaces/bus type 1x RS 485, 1x Ethernet (RJ45)
Number of industrial Ethernet interfaces 1
Number of RS 485 interfaces 1
Number of RS 422 interfaces 0
Number of USB interfaces 0
Number of wireless interfaces 0
PC card slot No
CF card slot No
Multimedia card/SD card slot combined
Protocols
Supports protocol for PROFINET IO Yes
PROFIsafe No
PROFIBUS No
EtherNet/IP No
AS-Interface No
Protocols (Ethernet)
● TCP/IP Yes
Further protocols
● MODBUS Yes
● other bus systems Yes
Communication functions
Wireless communication
● supported standards
— Radio standard WLAN 802.11 No
Standards, approvals, certificates
Certificate of suitability CE, cULus, C-TICK, SIBE
CE mark Yes
cULus Yes
RCM (formerly C-TICK) Yes
Suitable for safety functions Yes
Highest safety class achievable in safety mode
● Performance level according to ISO 13849-1 d
Use in hazardous areas
● cULus Class I Zone 2, Division 2 No
● FM Class I Division 2 No
Ambient conditions
Free fall
● Fall height, max. 1.5 m
Ambient temperature during operation
● min. 0 °C
● max. 40 °C
Ambient temperature during storage/transportation
● min. -20 °C
● max. 60 °C
Relative humidity
● Operation, max. 80 %
Operating systems
pre-installed operating system Windows CE
Configuration
Message indicator Yes
Alarm system (incl. buffer and acknowledgment) Yes
Process value display (output) Yes
Process value default (input) possible Yes
Recipe management Yes
Configuration software
● Configuration tool WinCC flexible Compact Version 2005 or higher (to be ordered separately)
● WinCC flexible Compact Yes
● WinCC flexible Standard Yes
● WinCC flexible Advanced Yes
● WinCC Basic (TIA Portal) No
● WinCC Comfort (TIA Portal) Yes
● WinCC Advanced (TIA Portal) Yes
● WinCC Professional (TIA Portal) Yes
Languages
Online languages
● Number of online/runtime languages 5
Project languages
● Languages per project 32
Functionality under WinCC (TIA Portal)
Libraries Yes
Applications/options Sm@rtService, Sm@rtAccess
● Web browser No
● Pocket Word No
● Pocket Excel No
● PDF Viewer No
● Media Player No
● SIMATIC WinCC Sm@rtServer Yes
● SIMATIC WinCC Audit No
● Connection point identification Yes
Number of Visual Basic Scripts No
● Debugging in the simulator No
Task planner Yes
Help system Yes
● Number of characters per info text 70
Message system
● Number of alarm classes 32
● Bit messages Yes
— Number of bit messages 2 000
● Analog messages Yes
— Number of analog messages 50
● Telegram message procedure Alarm S No
● System messages HMI Yes
● System messages PLC No
● System event, more (SIMATIC S7, SINUMERIK, SIMOTION, ... ) No
● Lines 1
● Number of characters per message 80
● Number of process values per message 8
● Message indicator Yes
● acoustic feedback No
● First/last value Yes
Recipe management
● Number of recipes 100
● Data records per recipe 200
● Entries per data record 200
● Recipe memory 32 KB integrated Flash, expandable
Variables
● Number of variables per device 1 024
● Number of variables per screen 50
● Limit values Yes
● Multiplexing Yes
● Structures Yes
Images
● Number of configurable images 500
● Permanent window/default Yes
● Start screen configurable Yes
● Image selection by PLC Yes
● Image number in the PLC Yes
Image objects
● Text objects 2 500 text elements
● Number of I/O fields per image 50
● Index of screen context No
● Return Yes
● Graphics object Bit maps, vector graphics
Complex image objects
● Status/control Yes; With SIMATIC S7
● dynamic objects Diagrams, bar graphs, sliders, invisible buttons
● Methods Trend / profile
● Bar graphs
— Number of bars per chart 5
● Limit value lines Yes
● Number of visible switches per project 1 000
Attributes for dynamic objects
● Color change Yes
● X/Y movement Yes
● Hide Yes
● Angle of rotation No
Lists
● Number of text lists per project 300
● Number of entries per text list 30
● Number of graphics lists per project 100
Archiving
● Number of archives per device 0
● Message archive No
● Process value archive No
● Archiving methods
— Sequential archive No
— Short-term archive No
● Memory location
— USB memory No
— Ethernet No
● Data storage format
— CSV No
— TXT No
● Online evaluation
— using trend curves No
Security
● Number of user groups 50
● Number of user rights 32
● Password export/import Yes
Transfer (upload/download)
● Transfer of configuration Serial, Ethernet, automatic transfer recognition
Process coupling
● Connection to controller S7-200, S7- 300/400, Win AC, PC (TCP/IP), SIMOTION, Modicon (Modbus), see the chapter "System interfaces"
● S7-1200 Yes; with restrictions
● S7-1500 Yes; with restrictions
● S7-200 Yes
— PPI (point-to-point) No
— PPI network No
— MPI No
— PROFIBUS DP No
— Ethernet Yes
● S7-300/400 Yes
— MPI No
— PROFIBUS DP No
— PROFINET Yes
● LOGO! No
● WinAC Yes
● SINUMERIK Yes
● SIMOTION Yes
● S5 No
— serial No
— PROFIBUS DP No
● TI 505 No
● Allen Bradley (EtherNet/IP) Yes
● Allen Bradley (DF1) No
● Allen Bradley (DF485) No
● Mitsubishi (MC TCP/IP) Yes
● Mitsubishi (FX) No
● Mitsubishi (MP4) No
● Telemecanique (ADJUST) No
● Telemecanique (Uni-Telway) No
● OMRON (FINS TCP) No
● OMRON (LINK/Multilink) No
● Modicon (Modbus TCP/IP) Yes
● Modicon (Modbus) No
● GE-Fanuc (SNP) No
Functions
● Key repeat No
● TAB sequence Yes
● Calculating functions Yes
● Animate Yes
● Menu tree editor No
● Unit switchover No
Service tools/configuration aids
● Clean screen No
● Touch calibration Yes
● Backup/Restore manually Yes
● Simulation Yes
● Device switchover Yes
● Delta transfer Yes
● Monitoring function for battery and memory Yes
● Trace (operation archive) No
Expandability/openness
● Open Platform Program Yes
Peripherals/Options
Peripherals Printer
Printer Yes
SIMATIC HMI MM memory card: Multi Media Card Yes
SIMATIC HMI SD memory card: Secure Digital memory card No
USB memory No
Mechanics/material
Enclosure material (front) plastic
Dimensions
Enclosure diameter 245 mm
Depth of housing 58 mm
Weights
Weight (without packaging) 1.3 kg

Fault description Possible solution
Why is my Mobile Panel 177 PN not supported in TIA Portal V16 or higher? The Mobile Panel 177 is no longer supported from TIA Portal V16 onwards. For existing projects, you should therefore use a compatible engineering version up to TIA Portal V14 or a suitable WinCC flexible environment. If a system modernisation is already planned, migration to the Mobile Panels 2nd Generation family specified by Siemens is the recommended approach.
Why can I not transfer my project or operating system to the Mobile Panel 177 PN? First check whether a supported transfer method has been configured. Siemens specifies serial transfer, Ethernet and automatic transfer detection for this device; the engineering PC can be connected via PROFINET through the Connection Box PN or directly to the panel via RS485. For touch devices, Siemens recommends performing a calibration under Control Panel > OP > Touch before starting the transfer. If the engineering version and panel operating system do not match, an OS update using ProSave is often the next logical step.
Why does the Mobile Panel 177 PN touchscreen respond inaccurately or not at all? The device uses an analogue resistive touchscreen and should only be operated with fingers or a touch stylus. Hard, pointed or excessive force can significantly reduce service life or permanently damage the touchscreen. If incorrect touch responses occur, first perform a calibration under Control Panel > OP > Touch. If the problem persists, the touch membrane or front operating section are common candidates for repair or replacement.
Why do the stop button or enabling switch not work as expected? On the Mobile Panel 177, the stop and enabling functions are safety-related and are evaluated via the connection box and the hard-wired safety circuit. Therefore, check not only the HMI project configuration but also the connection box type, wiring, safety monitoring device and the condition of the Connecting Cable PN. When using 1st Generation devices with 2nd Generation connection boxes, only a hard-wired F-system is permitted; a PROFIsafe-based F-system is not supported.
Why can I not establish a stable connection to an S7-1200 or S7-1500? According to Siemens, communication with S7-1200 and S7-1500 controllers is generally possible, but with certain limitations. Verify that communication has actually been configured via Ethernet/PROFINET, that the connection parameters match the Connection Box PN, and that the engineering version used still supports the panel. In existing installations, maintaining the original project environment up to TIA Portal V14 is often the most reliable approach.

With which software can 6AV6645-0BB01-0AX0 be configured?

The panel can be configured using WinCC flexible Compact from Version 2005 and with TIA Portal V11 to V14. An important point for procurement planning is that WinCC Basic is not supported for this device, whereas WinCC Comfort, WinCC Advanced and WinCC Professional are supported. For companies operating existing machines, this means that the available engineering environment should always be checked before purchasing or repairing the panel to ensure compatibility.

Is the Mobile Panel 177 PN still supported from TIA Portal V16 onwards?

No. Siemens explicitly lists the Mobile Panel 177 as a device that is no longer supported from TIA Portal V16 onwards. For existing installations, maintaining a compatible legacy project environment and retaining the installed panel is often more economical than carrying out an unplanned full system migration. If a technical upgrade is already planned, migration to a newer Mobile Panel platform should be considered.

Is there a Siemens-recommended successor for 6AV6645-0BB01-0AX0?

Siemens recommends the Mobile Panels 2nd Generation family as the successor platform for new machines and systems. However, the available sources do not identify a specific 1:1 successor MLFB for this exact device. For retrofit and migration projects, it is important to note that older Mobile Panel 177 PN devices can generally be used with 2nd Generation connection boxes, although this comes with specific limitations regarding the safety concept.

Which connection boxes or cables are required for the Mobile Panel 177 PN?

For the PN version, the Connecting Cable PN is intended for connection to the Terminal Box PN. Power is supplied via the connection box. For modernisation projects, Siemens also describes the use of compact, standard and advanced connection boxes from the Mobile Panels 2nd Generation family with the older Mobile Panel 177 PN. This can simplify spare-parts strategies but does not replace a detailed review of safety functions and wiring requirements.

Can 6AV6645-0BB01-0AX0 be operated with an S7-1200 or S7-1500?

Yes, but with limitations. Siemens states that communication with S7-1200 and S7-1500 controllers is generally possible, while also noting certain restrictions. In practice, the communication method, project status and required functionality should be reviewed before purchasing or replacing the panel. With older HMIs, successful operation often depends less on basic connectivity and more on the combination of firmware, engineering version, and the required diagnostic or safety functions.

When is repair more economical than replacement or purchasing a used unit?

Repair is particularly worthwhile when the existing project should remain unchanged, the machine must return to operation quickly and the installed device can still be economically repaired. Exchange units and used equipment are often more procurement-driven solutions when downtime costs exceed repair turnaround times or when immediately available spare units are required. EICHLER offers repair, exchange, used equipment and new-unit enquiries for this device. An optional test report is also available.

Important documents

Repair accompanying note

Download the repair accompanying note as a PDF, or use the digital repair registration and send your defective modules to the EICHLER Service Centre for repair.

Laughing Eichler technician points to green PDF with special sale of automation technology

Your shopping basket

Loading shopping basket