SIPLUS S7-300 CP340 RS 232 -25 ... +70 DEGREES C BASED ON 6ES7340-1AH01-0AE0 . COMMUNICATIONS PROCESSOR WITH RS232C-INTERFACE (V.24) INCL. CONFIGURING PACKAGE ON CD

Services for SIEMENS 6AG1340-1AH02-2AE0

Repair

2-5 days

from 646,27 €

to 950,40 €

Replacement

Used

New

1-3 days

1 Pcs.

1.266,20 €

1.202,89 €

1.202,89 € *

Please enter an offer recipient here.


Delivery information
Export identifier AL: N ECCN: N
Net weight 0.362
Quantity 1 Stück
Packaging quantity 1
Additional product information
Product status
EAN 4025515144113
UPC 662643024272
Static lot number 85389091
List indicator A&DSE/SIP ADD
Product group 4398
Country of origin DE
Compliance with the substance restrictions according to RoHS directive Since: 20120101
Product classifications Version Classification
eClass 4 27-24-03-09
eClass 5.1 27-24-22-08
eClass 6.0 27-24-22-08
ETIM 3 /
ETIM 4 EC001423
ETIM 5 EC001423

Attribute Value
General information
based on 6ES7340-1AH02-0AE0
Supply voltage
Rated value (DC)
● 24 V DC No; Power supply via backplane bus 5V
Input current
from backplane bus 5 V DC, max. 165 mA
Power loss
Power loss, typ. 0.6 W
Power loss, max. 0.85 W
Interfaces
Interfaces/bus type RS 232C (V.24)
Number of interfaces 1; Isolated
Transmission rate, min. 2.4 kbit/s
Transmission rate, max. 19.2 kbit/s
Point-to-point connection
● Cable length, max. 15 m
● supported printers HP-Deskjet, HP-Laserjet, IBM-Proprinter, user-defined
● Connector type 9-pin sub D connector
Integrated protocol driver
— 3964 (R) Yes
— ASCII Yes
— RK 512 No
— customer-specific drivers reloadable No
Telegram length, max.
— 3964 (R) 1 024 byte
— ASCII 1 024 byte
Transmission speed, RS 232
— with 3964 (R) protocol, max. 19.2 kbit/s
— with ASCII protocol, max. 9.6 kbit/s
— with printer driver, max. 9.6 kbit/s
Interrupts/diagnostics/status information
Diagnostics indication LED
● Receive RxD Yes
● Transmit TxD Yes
● Group error SF (red) Yes
Standards, approvals, certificates
CE mark Yes
UL approval Yes; File E239877
RCM (formerly C-TICK) Yes
KC approval Yes
EAC (formerly Gost-R) Yes
Ambient conditions
Ambient temperature during operation
● min. -25 °C; = Tmin
● max. 70 °C; = Tmax; 60 °C @ UL/cUL, ATEX and FM use
Ambient temperature during storage/transportation
● min. -40 °C
● max. 70 °C
Altitude during operation relating to sea level
● Installation altitude above sea level, max. 5 000 m
● Ambient air temperature-barometric pressure-altitude Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)
Relative humidity
● With condensation, tested in accordance with IEC 60068-2-38, max. 100 %; RH incl. condensation/frost (no commissioning under condensation conditions)
Resistance
Use in stationary industrial systems
— to biologically active substances according to EN 60721-3-3 Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
— to chemically active substances according to EN 60721-3-3 Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-3 Yes; Class 3S4 incl. sand, dust, *
Use on ships/at sea
— to biologically active substances according to EN 60721-3-6 Yes; Class 6B2 mold and fungal spores (excluding fauna); Class 6B3 on request
— to chemically active substances according to EN 60721-3-6 Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-6 Yes; Class 6S3 incl. sand, dust; *
Usage in industrial process technology
— Against chemically active substances acc. to EN 60654-4 Yes; Class 3 (excluding trichlorethylene)
— Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04 Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)
Remark
— Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04 * The supplied plug covers must remain in place over the unused interfaces during operation!
Software
Block
● FB length in RAM, max. 2 700 byte; Data communication, sending and receiving
Connection method
Design of electrical connection for supply voltage Over backplane bus
Dimensions
Width 40 mm
Height 125 mm
Depth 120 mm
Weights
Weight, approx. 300 g

Important documents