SIEMENS 6AV2124-0MC01-0AX0

  • SIEMENS | HMI | Touch Panels

  • EICHLER-art.no.: K0251526
  • EAN: 4025515079002
  • UPC: 040892686050

Product description

SIMATIC HMI TP1200 COMFORT, COMFORT PANEL, TOUCH OPERATION, 12 WIDESCREEN-TFT-DISPLAY, 16 MIL. COLORS, PROFINET INTERFACE, MPI/PROFIBUS DP INTERFACE, 12 MB USER MEMORY, WINDOWS CE 6.0, CONFIGURABLE FROM WINCC COMFORT V11

Services for SIEMENS 6AV2124-0MC01-0AX0

Repair

1-3 days

from 1.374,51 €

to 2.474,12 €

per pc. 159,00 €

Replacement

1-3 days

10+ Pcs.

2.615,40 €

per pc. 159,00 €

2.615,40 € *

Please enter an offer recipient here.


Used

1-3 days

10+ Pcs.

2.906,00 €

per pc. 159,00 €

2.906,00 € *

Please enter an offer recipient here.


New

1-3 days

10+ Pcs.

3.196,60 €

3.196,60 € *

Please enter an offer recipient here.


Delivery information
Export identifier AL: N ECCN: 5A992
Net weight 3.46
Quantity 1 Stück
Packaging quantity 1
Additional product information
Product status
EAN 4025515079002
UPC 040892686050
Static lot number 85371091
List indicator ST80.1N
Product group 3404
Country of origin DE
Compliance with the substance restrictions according to RoHS directive Since: 20110131
Product classifications Version Classification
eClass 4 27-36-01-02
eClass 5.1 27-24-23-02
eClass 6.0 27-24-23-02
ETIM 3 /
ETIM 4 EC001412
ETIM 5 EC001412

What is 6AV2124-0MC01-0AX0 (TP1200 Comfort)?

The 6AV2124-0MC01-0AX0 is a Siemens SIMATIC HMI TP1200 Comfort, a 12-inch touch panel for machine and plant visualisation. It combines a large widescreen display with robust industrial interfaces (PROFINET + PROFIBUS/MPI) and is widely used for both new machines and as a replacement in existing systems, especially when downtime needs to be resolved quickly.

Technical key data at a glance

The panel features a 12.1" TFT widescreen display with 1280 × 800 resolution and 16 million colours. It is powered by 24 V DC (19.2–28.8 V range) with a typical power consumption of around 20 W.

For engineering, Siemens specifies WinCC Comfort V11 as the configuration environment, based on a Windows CE 6.0 platform.

Display & touch: 12.1" widescreen (1280 × 800)

The panel uses an analog resistive touchscreen, which typically allows operation with gloves or a stylus depending on the application environment. The backlight is rated at approximately 80,000 hours MTBF (at 25 °C), and brightness is dimmable from 0–100%, which is important for long-term industrial use in continuous operation.

Communication: PROFINET (2-port) and PROFIBUS/MPI

For system integration, the device offers Industrial Ethernet / PROFINET with a 2-port switch and a combined RS485/RS422 interface for PROFIBUS and MPI. This allows integration into both modern Ethernet-based architectures and legacy Siemens S7 environments.

Memory, interfaces & media: 12 MB, USB, SD slots

Siemens specifies 12 MB user memory, plus 2 × USB 2.0 ports and 2 × SD card slots. These features support firmware updates, backup/restore procedures, and service-related data handling.

Protection rating & installation: IP65 front, mounting cut-out

The front panel is rated IP65, while the rear is IP20. Typical installation dimensions include a front cut-out of 310 × 221 mm and an installation depth of around 64 mm, which supports straightforward replacement in existing control cabinets without major mechanical changes.

Lifecycle status: phase-out strategy for installed base

Siemens classifies this device in a “Phase Out Announce” lifecycle status, meaning it is transitioning towards end-of-life but is still relevant for installed base support. For operators, this increases the importance of repair strategies, tested replacement units, and spare part planning to maintain system availability.

Repair vs. replacement: reducing downtime

In case of failure, the key factor is minimizing downtime and restoring operability quickly. In practice, tested exchange units or repair services are often more efficient than long troubleshooting cycles. Providers such as EICHLER offer functional testing and warranties of up to 36 months, which can make replacement decisions more predictable from a risk and cost perspective.

Identification & ordering information

For clear identification, the relevant references include MPN 6AV2124-0MC01-0AX0, EICHLER article number K0251526, and EAN 4025515079002.

General information
Product type designation TP1200 Comfort
Display
Design of display TFT
Screen diagonal 12.1 in
Display width 261.1 mm
Display height 163.2 mm
Number of colors 16 777 216
Resolution (pixels)
● Horizontal image resolution 1 280 pixel
● Vertical image resolution 800 pixel
Backlighting
● MTBF backlighting (at 25 °C) 80 000 h
● Backlight dimmable Yes; 0-100 %
Control elements
Keyboard fonts
● Function keys
— Number of function keys 0
— Number of function keys with LEDs 0
● Keys with LED No
● System keys No
● Numeric keyboard Yes; Onscreen keyboard
● alphanumeric keyboard Yes; Onscreen keyboard
Touch operation
● Design as touch screen Yes; Analog-resistive
Expansions for operator control of the process
● DP direct LEDs (LEDs as S7 output I/O)
— F1...Fx 0
● Direct keys (keys as S7 input I/O)
— F1...Fx 0
● Direct keys (touch buttons as S7 input I/O) 40
Installation type/mounting
Mounting position vertical
Wall mounting/direct mounting No
Mounting in portrait format possible Yes
Mounting in landscape format possible Yes
maximum permissible angle of inclination without external ventilation 35°
Supply voltage
Type of supply voltage DC
Rated value (DC) 24 V
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V
Input current
Current consumption (rated value) 0.85 A
Starting current inrush I²t 0.5 A²·s
Power
Active power input, typ. 20 W
Processor
Processor type X86
Memory
Flash Yes
RAM Yes
Memory available for user data 12 Mbyte
Type of output
Info LED No
Power LED No
Error LED No
Acoustics
● Buzzer No
● Speaker Yes
Time of day
Clock
● Hardware clock (real-time) Yes
● Software clock Yes
● retentive Yes; Back-up duration typically 6 weeks
● synchronizable Yes
Interfaces
Number of industrial Ethernet interfaces 1; 2 ports (switch)
Number of RS 485 interfaces 1; RS 422 / 485 combined
Number of RS 422 interfaces 0; together with RS 485
Number of RS 232 interfaces 0
Number of USB interfaces 2; USB 2.0
● USB Mini B 1; 5-pole
Number of 20 mA interfaces (TTY) 0
Number of parallel interfaces 0
Number of other interfaces 0
Number of SD card slots 2
With software interfaces No
Industrial Ethernet
● Industrial Ethernet status LED 2
● Number of ports of the integrated switch 2
Protocols
PROFINET Yes
Supports protocol for PROFINET IO Yes
IRT Yes; As of WinCC V12
PROFIBUS Yes
EtherNet/IP Yes
MPI Yes
Protocols (Ethernet)
● TCP/IP Yes
● DHCP Yes
● SNMP Yes
● DCP Yes
● LLDP Yes
WEB characteristics
● HTTP Yes
● HTTPS Yes
● HTML Yes
● XML Yes
● CSS Yes
● Active X Yes
● JavaScript Yes
● Java VM No
Redundancy mode
Media redundancy
— MRP Yes; As of WinCC V12
Further protocols
● CAN No
● MODBUS Yes
Interrupts/diagnostics/status information
Diagnoses
● Diagnostic information readable Yes; S7 controller
EMC
Emission of radio interference acc. to EN 55 011
● Limit class A, for use in industrial areas Yes
● Limit class B, for use in residential areas No
Degree and class of protection
IP (at the front) IP65
IP (rear) IP20
NEMA (front)
● Enclosure Type 4 at the front Yes
● Enclosure Type 4x at the front Yes
Standards, approvals, certificates
CE mark Yes
cULus Yes
RCM (formerly C-TICK) Yes
KC approval Yes
Ecological footprint
● environmental product declaration Yes
Global warming potential
— global warming potential, (total) [CO2 eq] 301 kg
— global warming potential, (during production) [CO2 eq] 81.2 kg
— global warming potential, (during operation) [CO2 eq] 221 kg
— global warming potential, (after end of life cycle) [CO2 eq] -2.25 kg
Use in hazardous areas
● ATEX Zone 2 Yes
● ATEX Zone 22 Yes
● IECEx Zone 2 Yes
● IECEx Zone 22 Yes
● cULus Class I Zone 1 No
● cULus Class I Zone 2, Division 2 Yes
● FM Class I Division 2 Yes
Marine approval
● Germanischer Lloyd (GL) Yes; As of product version: 10
● American Bureau of Shipping (ABS) Yes; As of product version: 10
● Bureau Veritas (BV) Yes; As of product version: 10
● Det Norske Veritas (DNV) Yes; As of product version: 10
● Lloyds Register of Shipping (LRS) Yes; As of product version: 10
● Nippon Kaiji Kyokai (Class NK) Yes; As of product version: 10
● Polski Rejestr Statkow (PRS) No
Ambient conditions
Suited for indoor use Yes
Suited for outdoor use No
Ambient temperature during operation
Operation (vertical installation)
— For vertical installation, min. 0 °C
— For vertical installation, max. 50 °C; (55 °C, see entry ID: 64847814)
Operation (max. tilt angle)
— At maximum tilt angle, min. 0 °C
— At maximum tilt angle, max. 40 °C
Operation (vertical installation, portrait format)
— For vertical installation, min. 0 °C
— For vertical installation, max. 40 °C
Operation (max. tilt angle, portrait format)
— At maximum tilt angle, min. 0 °C
— At maximum tilt angle, max. 35 °C
Ambient temperature during storage/transportation
● min. -20 °C
● max. 60 °C
Relative humidity
● Operation, max. 90 %; no condensation
Operating systems
proprietary No
pre-installed operating system
● Windows CE Yes
Configuration
Message indicator Yes
Alarm system (incl. buffer and acknowledgment) Yes
Process value display (output) Yes
Process value default (input) possible Yes
Recipe management Yes
Configuration software
● STEP 7 Basic (TIA Portal) No
● STEP 7 Professional (TIA Portal) No
● WinCC flexible Compact No
● WinCC flexible Standard No
● WinCC flexible Advanced No
● WinCC Basic (TIA Portal) No
● WinCC Comfort (TIA Portal) Yes; from V11
● WinCC Advanced (TIA Portal) Yes; from V11
● WinCC Professional (TIA Portal) Yes; from V11
Languages
Online languages
● Number of online/runtime languages 32
Project languages
● Languages per project 32
Functionality under WinCC (TIA Portal)
Libraries Yes
Applications/options
● Web browser Yes
● Pocket Word Yes
● Pocket Excel Yes
● PDF Viewer Yes
● Media Player Yes
● SIMATIC WinCC Sm@rtServer Yes
● SIMATIC WinCC Audit Yes
Number of Visual Basic Scripts Yes
Task planner
● time-controlled Yes
● task-controlled Yes
Help system
● Number of characters per info text 70
Message system
● Number of alarm classes 32
● Bit messages Yes
— Number of bit messages 4 000
● Analog messages Yes
— Number of analog messages 200
● S7 alarm number procedure Yes
● System messages HMI Yes
● System event, more (SIMATIC S7, SINUMERIK, SIMOTION, ... ) Yes
● Number of characters per message 80
● Number of process values per message 8
● Acknowledgment groups Yes
● Message indicator Yes
● Message buffer
— Number of entries 1 024
— Circulating buffer Yes
— retentive Yes
— maintenance-free Yes
Recipe management
● Number of recipes 300
● Data records per recipe 500
● Entries per data record 1 000
● Size of internal recipe memory 2 Mbyte
● Recipe memory expandable Yes
Variables
● Number of variables per device 2 048
● Number of variables per screen 400
● Limit values Yes
● Multiplexing Yes
● Structures Yes
● Arrays Yes
Images
● Number of configurable images 500
● Permanent window/default Yes
● Global image Yes
● Pop-up images Yes
● Slide-in images Yes
● Image selection by PLC Yes
● Image number in the PLC Yes
Image objects
● Number of objects per image 400
● Text fields Yes
● I/O fields Yes
● Graphic I/O fields (graphics list) Yes
● Symbolic I/O fields (text list) Yes
● Date/time fields Yes
● Switches Yes
● Buttons Yes
● Graphic display Yes
● Icons Yes
● Geometric objects Yes
Complex image objects
● Number of complex objects per screen 20
● Alarm view Yes
● Trend view Yes
● User view Yes
● Status/control Yes
● Sm@rtClient view Yes
● Recipe view Yes
● f(x) trend view Yes
● System diagnostics view Yes
● Media Player Yes
● HTML browser Yes
● PDF display Yes
● IP camera display Yes
● Bar graphs Yes
● Sliders Yes
● Pointer instruments Yes
● Analog/digital clock Yes
Lists
● Number of text lists per project 500
● Number of entries per text list 500
● Number of graphics lists per project 500
● Number of entries per graphics list 500
Archiving
● Number of archives per device 50
● Number of entries per archive 20 000
● Message archive Yes
● Process value archive Yes
● Archiving methods
— Sequential archive Yes
— Short-term archive Yes
● Memory location
— Memory card Yes
— USB memory Yes
— Ethernet Yes
● Data storage format
— CSV Yes
— TXT Yes
— RDB Yes
Security
● Number of user groups 50
● Number of user rights 32
● Number of users 50
● Password export/import Yes
● SIMATIC Logon Yes
Logging through printer
● Alarms Yes
● Report (shift log) Yes
● Hardcopy Yes
● Electronic print to file Yes; PDF, HTML
Character sets
● Keyboard fonts
— US English Yes
Transfer (upload/download)
● MPI/PROFIBUS DP Yes
● USB Yes
● Ethernet Yes
● using external storage medium Yes
Process coupling
● S7-1200 Yes
● S7-1500 Yes
● S7-200 Yes
● S7-300/400 Yes
● LOGO! Yes
● WinAC Yes
● SINUMERIK Yes; with SINUMERIK option package
● SIMOTION Yes
● Allen Bradley (EtherNet/IP) Yes
● Allen Bradley (DF1) Yes
● Mitsubishi (MC TCP/IP) Yes
● Mitsubishi (FX) Yes
● OMRON (FINS TCP) No
● OMRON (LINK/Multilink) Yes
● Modicon (Modbus TCP/IP) Yes
● Modicon (Modbus) Yes
● OPC UA Client Yes
● OPC UA Server Yes
Service tools/configuration aids
● Backup/Restore manually Yes
● Backup/Restore automatically Yes
● Simulation Yes
● Device switchover Yes
Peripherals/Options
Printer Yes
SIMATIC HMI MM memory card: Multi Media Card Yes; Up to 128 MB
SIMATIC HMI SD memory card: Secure Digital memory card Yes; Up to 2 GB
SIMATIC HMI CF memory card Compact Flash Card No
USB memory Yes
SIMATIC IPC USB Flashdrive (USB stick) Yes; Up to 16 GB
SIMATIC HMI USB stick Yes; Up to 8 GB
Network camera Yes
Mechanics/material
Enclosure material (front)
● Plastic No
● Aluminum Yes
● Stainless steel No
Dimensions
Width of the housing front 330 mm
Height of housing front 241 mm
Mounting cutout, width 310 mm
Mounting cutout, height 221 mm
mounting depth 64 mm
Weights
Weight (without packaging) 2.8 kg
Weight (with packaging) 3.5 kg

Fault description Possible solution
Touch does not respond or only partially responds – what are the first checks? Typical causes are contamination or moisture on the front panel or an incorrect touch calibration / HMI runtime issue. First steps: clean the panel surface (front is IP65 rated), restart the device, and check the project/runtime status. If a hardware issue is still suspected, use a replacement unit for comparison testing.
Display is dark or only faintly visible – what is the common cause? In many cases the backlight or its control circuit is affected. Siemens specifies a backlight MTBF of 80,000 hours, so ageing effects can occur after long operating times.
PROFINET connection not working (no communication with PLC) – what should be checked? The panel uses Industrial Ethernet with a 2-port switch. Check the correct port, IP configuration, PROFINET device name, switch/link status, and project assignment.
PROFIBUS/MPI communication disturbed – what are typical causes? For RS485-based communication, common issues include missing termination, faulty connectors, incorrect baud rate or station address, and wiring problems. Always verify both physical bus wiring and project parameters.
Backup/restore or project transfer fails – what helps fastest? The panel supports USB and SD storage (2 slots). In practice, try a different storage medium, check file system compatibility, or use another USB stick, then repeat the backup/restore process.
When is repair or replacement better than continued troubleshooting? If visualisation is production-critical or failures occur repeatedly, a tested replacement unit is often the fastest way to restore system availability. This can significantly reduce downtime risk and is typically supported with up to 36 months warranty depending on service offering, making it a more predictable option than prolonged fault analysis.

What is the 6AV2124-0MC01-0AX0 used for?

It is used for machine and plant visualisation as a TP1200 Comfort with 12" touch display and industrial interfaces—especially as a 1:1 replacement in SIMATIC S7 environments.

Which interfaces are integrated?

It includes PROFINET (2-port switch) and RS485/RS422 for PROFIBUS/MPI, as well as 2× USB 2.0 ports and 2× SD card slots.

Which display specifications are important for replacement?

The panel features a 12.1" display with 1280 × 800 resolution and 16 million colours, an analog resistive touchscreen, and a backlight MTBF of 80,000 hours.

What power supply does the panel require?

It is powered by 24 V DC (19.2–28.8 V range) with a typical power consumption of around 20 W (0.85 A).

Why is the “phase-out” status important for purchasing decisions?

With a Phase Out Announce status, procurement becomes more time-critical. In practice, tested replacement units and repair services help maintain system availability and avoid downtime without immediately requiring a full retrofit.

Important documents

Repair accompanying note

Download the repair accompanying note as a PDF, or use the digital repair registration and send your defective modules to the EICHLER Service Centre for repair.

Laughing Eichler technician points to green PDF with special sale of automation technology

Quality & warranty

Outstanding service quality with every handle

Two Eichler technicians high-five each other after a successful repair

Your shopping basket