SIEMENS 6AV6641-0CA01-0AX0
- EICHLER-art.no.: K0136164
- EAN: 4025515070566
Product description
SIMATIC OPERATOR PANEL OP77B BACKLIT LC DISPLAY, 4.5" DISPL. W. GRAPHICS CAPABIL MPI-/PROFIBUS-DP INTERFACE UPTO 12 MB, PRINTER/USB INTERFACE, SLOT FOR MMC CARD, FOR CONFIGURATION OF WINCC FLEXIBLE 2004 COMPACT
Services for SIEMENS 6AV6641-0CA01-0AX0
SIEMENS |
6AV6641-0CA01-0AX0 –
additional product information
| Delivery information | |||
|---|---|---|---|
| Export identifier | AL: ECCN: | ||
| Net weight | 0.616 | ||
| Quantity | 1 Stück | ||
| Packaging quantity | 1 | ||
| Additional product information | |||
|---|---|---|---|
| Product status | EOP: 2008-07-11 | ||
| EAN | 4025515070566 | ||
| UPC | / | ||
| Static lot number | 85371098 | ||
| List indicator | / | ||
| Product group | 4368 | ||
| Country of origin | DE | ||
| Compliance with the substance restrictions according to RoHS directive | Since: / | ||
| Product classifications | Version | Classification | |
|---|---|---|---|
| eClass | 4 | / | |
| eClass | 5.1 | / | |
| eClass | 6.0 | / | |
| ETIM | 3 | / | |
| ETIM | 4 | / | |
| ETIM | 5 | / | |
What is 6AV6641-0CA01-0AX0 and where is it used?
6AV6641-0CA01-0AX0 is a SIEMENS SIMATIC Operator Panel OP77B with keypad operation for classic machine and system interfaces. The device was introduced as a graphics-capable successor to the OP7 and is designed for operating, display and alarm functions in existing installations. Typical applications include production machinery, packaging systems, conveyor technology, machine tools and retrofit projects where MPI/PROFIBUS-DP communication, robust front-panel operation and compact installation dimensions are required. For maintenance personnel, the part number is particularly important when an existing panel must be identified on a 1:1 basis, downtime must be bridged quickly or an older visualisation system must be kept operational.
Overview of the key technical data and what they mean
The OP77B features a backlit 4.5-inch STN monochrome display with a resolution of 160 × 64 pixels and a membrane keypad. Important features for everyday control cabinet applications include a 24 V DC power supply, IP65 front protection, an MMC card slot, USB, and communication interfaces including RS232, RS422 and RS485, as well as MPI/PROFIBUS DP up to 12 Mbit/s. The 1 MB user memory is sufficient for typical WinCC flexible projects used in small and medium-sized machines. The combination of 23 system keys, 8 function keys and 4 LED keys is well suited to operator screens, acknowledgements and clear status indication. The panel can be engineered using WinCC flexible Compact from Version 2004 and integrated into existing legacy systems.
Product status, life-cycle status and obsolescence
For 6AV6641-0CA01-0AX0, the EICHLER product page lists a product status of EOP: 2008-07-11. This is a clear indication of obsolescence in existing installations, meaning that procurement, replacement capability and data retention strategies should be actively managed. Siemens lists the later OP77B variant 6AV6641-0CA01-0AX1 as a spare part, and the Siemens migration guide maps the OP77B 0AX1 towards the KP400 Comfort 6AV2124-1DC01-0AX0. For operators, this means that a modern successor should be viewed as a migration path rather than an automatically compatible direct replacement. Particularly with older projects, the engineering version, communication method, panel cut-out, operating philosophy and data transfer requirements must all be assessed separately.
Available EICHLER services and why they are relevant in practice
For this part number, EICHLER offers repair, exchange, used equipment and new equipment on request. These services are particularly relevant for companies that need to minimise downtime or reduce spare-parts risks associated with discontinued HMIs. Repair is specified with a turnaround time of 1–3 days and includes technical cleaning, preventive maintenance, comprehensive functional testing and a minimum 24-month warranty. For maintenance and purchasing departments, this is especially useful when the original device should remain mechanically and communicatively compatible with the existing installation. Exchange and used-equipment options are valuable when time is more critical than carrying out internal fault analysis. The optional test report is particularly useful when traceability and documented functional verification are required internally.
| Attribute | Value |
|---|---|
| Display | |
| Design of display | STN |
| Screen diagonal | 4.5 in |
| Color display | No |
| Number of colors | 2; Black/white |
| Resolution (pixels) | |
| ● Horizontal image resolution | 160 Pixel |
| ● Vertical image resolution | 64 Pixel |
| Backlighting | |
| ● MTBF backlighting (at 25 °C) | 100 000 h |
| Control elements | |
| Control elements | Membrane keyboard |
| Keyboard fonts | |
| ● Membrane keyboard | |
| — user-definable label membrane keys | Yes |
| ● Function keys | Yes |
| — Number of function keys | 8 |
| — Number of function keys with LEDs | 4 |
| ● System keys | |
| — Number of system keys | 23 |
| ● Numeric keyboard | Yes |
| ● alphanumeric keyboard | Yes |
| ● hexadecimal keyboard | Yes |
| ● Multi-key operation | Yes |
| Connection type | |
| ● Type of connection for mouse/keyboard/barcode reader | - / - / - |
| Installation type/mounting | |
| Mounting position | vertical |
| maximum permissible angle of inclination without external ventilation | 80° |
| Input current | |
| Current consumption (rated value) | 0.2 A |
| Starting current inrush I²t | 0.5 A²·s |
| Processor | |
| Processor type | ARM |
| Memory | |
| Type of memory | Flash / RAM |
| Memory available for user data | 1 000 kbyte |
| Type of output | |
| Info LED | Yes |
| Power LED | No |
| Error LED | No |
| Time of day | |
| Clock | |
| ● Type | Software clock, no battery backup |
| ● retentive | No |
| ● synchronizable | No |
| Interfaces | |
| Interfaces/bus type | 1x RS 232, 1x RS 422, 1x RS 485 (max. 12 Mbit/s) |
| Number of industrial Ethernet interfaces | 0 |
| Number of RS 485 interfaces | 1 |
| Number of RS 422 interfaces | 1 |
| Number of USB interfaces | 1 |
| Multimedia card/SD card slot | 1x MultiMediaCard slot |
| Degree and class of protection | |
| IP (at the front) | IP65 |
| IP (rear) | IP20 |
| NEMA (front) | NEMA 4x, NEMA 12 (when installed) |
| Standards, approvals, certificates | |
| Certificate of suitability | CE, GL, ABS, BV, DNV, LRS, FM Class I Div. 2, UL, CSA, cULus, EX-Zone 2/22, C-TICK, NEMA 4x, NEMA 12 |
| cULus | Yes |
| EAC (formerly Gost-R) | No |
| Use in hazardous areas | |
| ● ATEX Zone 2 | Yes |
| ● ATEX Zone 22 | Yes |
| ● FM Class I Division 2 | Yes |
| Marine approval | |
| ● Germanischer Lloyd (GL) | Yes |
| ● American Bureau of Shipping (ABS) | Yes |
| ● Bureau Veritas (BV) | Yes |
| ● Det Norske Veritas (DNV) | Yes |
| ● Lloyds Register of Shipping (LRS) | Yes |
| ● Nippon Kaiji Kyokai (Class NK) | Yes |
| ● Polski Rejestr Statkow (PRS) | No |
| Ambient conditions | |
| Ambient temperature during storage/transportation | |
| ● min. | -20 °C |
| ● max. | 60 °C |
| Relative humidity | |
| ● Operation, max. | 90 % |
| Operating systems | |
| pre-installed operating system | Windows CE |
| Configuration | |
| Configuration software | |
| ● Configuration tool | WinCC flexible Compact Version 2004 or higher (to be ordered separately) |
| Languages | |
| Online languages | |
| ● Number of online/runtime languages | 5 |
| Project languages | |
| ● Languages per project | 32 |
| Functionality under WinCC (TIA Portal) | |
| Libraries | Yes |
| Help system | Yes |
| ● Number of characters per info text | 320 |
| Message system | |
| ● Number of alarm classes | 32 |
| ● Number of messages | 1 000 |
| ● Bit messages | Yes |
| — Number of bit messages | 1 000 |
| ● Analog messages | Yes |
| ● Telegram message procedure Alarm S | Yes |
| ● System messages HMI | Yes |
| ● System messages PLC | Yes |
| ● System messages, other (SIMATIC S7, Sinumerik, Simotion, etc.) | No |
| ● Number of characters per message | 80 |
| ● Number of process values per message | 8 |
| ● Acknowledgment groups | Yes |
| ● Message indicator | No |
| ● acoustic feedback | No |
| ● First/last value | Yes |
| Recipe management | |
| ● Number of recipes | 100 |
| ● Data records per recipe | 200 |
| ● Entries per data record | 200 |
| ● Recipe memory | 32 KB integrated Flash, expandable |
| Variables | |
| ● Number of variables per device | 1 000 |
| ● Number of variables per screen | 30 |
| ● Limit values | Yes |
| ● Multiplexing | Yes |
| Images | |
| ● Number of configurable images | 500 |
| ● Permanent window/default | Yes |
| ● Start screen configurable | Yes |
| ● Image selection by PLC | Yes |
| ● Image number in the PLC | Yes |
| Image objects | |
| ● Text objects | 2 500 text elements |
| ● Number of I/O fields per image | 30 |
| ● Number of date/time fields | 0 |
| ● Index of screen context | No |
| ● Return | Yes |
| ● Graphics object | Bit maps, icons, icon (full-screen) |
| — Icons | 1 000 |
| — Icon (full screen) | 100 |
| Complex image objects | |
| ● dynamic objects | Bar graphs |
| ● Bar graphs | |
| — Number of bars per chart | 5 |
| ● Pointer instruments | |
| — Number of analog indicators per image | 0 |
| ● Limit value lines | Yes |
| ● Number of alphanumerical fields | 1 000 |
| — alphanumeric fields per image | 30 |
| ● Number of numerical fields | 1 000 |
| — numerical fields per image | 30 |
| ● Number of password fields | 0 |
| ● Number of visible switches per project | |
| — visible switches per image | 0 |
| — hidden switches per image | 0 |
| ● Number of status switches per project | |
| — Number of status switches per image | 0 |
| ● Number of selector switches per project | |
| — Selector switches per image | 0 |
| ● Number of decade switches per project | |
| — Decade switches per image | 0 |
| ● Number of signal lamps per project | |
| — Signal lamps per image | 0 |
| Attributes for dynamic objects | |
| ● Angle of rotation | No |
| Lists | |
| ● Number of text lists per project | 300 |
| ● Number of graphics lists per project | 0 |
| ● Number of graphic lists per image | 0 |
| ● Number of entries per graphics list | 0 |
| Security | |
| ● Number of user groups | 50 |
| ● Number of user rights | 32 |
| ● Password export/import | Yes |
| Logging through printer | |
| ● Recording/Printing | Alarms, report (shift report), hardcopy |
| Transfer (upload/download) | |
| ● Transfer of configuration | MPI/PROFIBUS DP, serial, USB, by means of external storage medium, automatic transfer recognition |
| Process coupling | |
| ● Connection to controller | S5, S7-200, S7-300/400, TI 505, Win AC, Allen Bradley (DF1), Allen Bradley (DF485), Mitsubishi (FX), OMRON (LINK/Multilink), Modicon (Modbus), further non-Siemens drivers, see chapter "System interfaces" |
| ● S7-200 | Yes |
| — PPI (point-to-point) | Yes |
| — PPI network | Yes |
| — MPI | Yes |
| — PROFIBUS DP | Yes |
| ● S7-300/400 | Yes |
| — MPI | Yes |
| — PROFIBUS DP | Yes |
| — PROFINET | No |
| ● S5 | Yes |
| — serial | Yes |
| — PROFIBUS DP | Yes |
| ● TI 505 | Yes |
| ● Allen Bradley (DF1) | Yes |
| ● Allen Bradley (DF485) | Yes |
| ● Mitsubishi (FX) | Yes |
| ● Mitsubishi (MP4) | Yes |
| ● Telemecanique (ADJUST) | No |
| ● Telemecanique (Uni-Telway) | No |
| ● OMRON (LINK/Multilink) | Yes |
| ● Modicon (Modbus) | Yes |
| ● GE-Fanuc (SNP) | Yes |
| Functions | |
| ● Key repeat | Yes |
| ● TAB sequence | Yes |
| ● Calculating functions | Yes |
| ● Animate | Yes |
| ● Menu tree editor | Yes |
| ● Unit switchover | No |
| Service tools/configuration aids | |
| ● Clean screen | No |
| ● Touch calibration | No |
| ● Backup/Restore manually | Yes |
| ● Simulation | Yes |
| ● Device switchover | Yes |
| ● Delta transfer | Yes |
| ● Monitoring function for battery and memory | No |
| ● Trace (operation archive) | No |
| Expandability/openness | |
| ● Open Platform Program | No |
| Peripherals/Options | |
| Peripherals | Printer |
| SIMATIC HMI MM memory card: Multi Media Card | Yes |
| Dimensions | |
| Width of the housing front | 150 mm |
| Height of housing front | 186 mm |
| Overall depth | 38.5 mm |
| Weights | |
| Weight (without packaging) | 0.5 kg |
| Fault description | Possible solution |
|---|---|
| Why does my OP77B display “Unsupported storage card detected!”? | The OP77B requires a compatible MMC for backup and restore operations. If a SIMATIC S7 MMC is inserted instead, the device displays the message “Unsupported storage card detected!”. The solution is to replace it with the appropriate memory card. Afterwards, the backup or restore process can be started again via Info/Settings > Logon/Settings > Backup/Restore. |
| Why do I receive error 140015 or an HSA message on my OP77B? | Siemens identifies incorrect baud rates, incorrect bus parameters such as HSA, an OP address above the HSA value or an incorrect interrupt vector as possible causes of error 140015. Therefore, check the bus speed on all participants, ensure that the MPI/DP address is assigned only once within the network and verify that the configured parameters match both the project and the hardware. HSA-related issues are also discussed in Siemens forums in connection with the OP77B and WinCC flexible. |
| Why does my OP77B remain in transfer mode or fail to establish a connection to the PG? | At least one data channel must be enabled on the OP77B before a project can be transferred. For MPI/PROFIBUS DP or USB, the relevant settings are “Enable (remote off)” or “Enable (remote on)”. In addition, the address and baud rate must match the network configuration. In practice, transfers often succeed only when the panel is deliberately placed into transfer mode or when the panel parameters are correctly aligned with the project configuration. After project startup or transfer, settings may be overwritten again by the project. |
| Why does my OP77B start only in the bootloader? | After an interrupted reset procedure or a failed operating system process, the panel may remain in the bootloader. In this case, an OS update using ProSave is the most obvious solution. Forum discussions describing this exact symptom on the OP77B recommend performing an OS update with the option “Reset to factory settings” enabled. Siemens also explains that, after a restore or CE image recovery, the panel reboots and the remaining data is restored afterwards. It is important not to disconnect power from the device before the process has completed. |
| Why does the OP77B no longer communicate correctly with the controller after migration or modification? | Siemens identifies several potential causes during migration projects, including an incorrect driver, unsuitable interface settings, missing communication parameter adjustments and, in certain S5-DP configurations, the need to replace the controller program with FB158. Practical reports additionally mention swapped PROFIBUS wires, short circuits at the connector or incorrect transfer and bus mode settings. Therefore, after every migration, the driver, DIL/interface settings, cable wiring, bus parameters and project-specific PLC program blocks should be checked systematically. |
Is 6AV6641-0CA01-0AX0 still available or has it been discontinued?
This part number clearly belongs to the obsolescence category. The EICHLER product page lists EOP 2008-07-11. At the same time, the later OP77B variant 6AV6641-0CA01-0AX1 can still be found within the Siemens support and spare-parts environment. For operators, this means that original supply is no longer guaranteed, making repair, exchange, tested used equipment and well-documented spare-parts strategies increasingly important.
Which software is used to engineer the OP77B?
The panel is designed for WinCC flexible Compact from Version 2004. For service tasks such as transfer, backup/restore and OS updates, ProSave is the primary tool. This combination is particularly important in existing installations because many problems are caused not by the device itself but by missing or outdated project data. Anyone intending to continue operating an OP77B should therefore ensure that the engineering software, backup files and relevant service expertise remain available.
Which controllers can the OP77B communicate with?
According to Siemens, the OP77B supports communication with SIMATIC S5, S7-200, S7-300/400 and various third-party controllers. At device level, the relevant interfaces are RS232, RS422, RS485 and MPI/PROFIBUS DP up to 12 Mbit/s. For many existing machines, this versatility is precisely why the OP77B remains in demand today: it integrates into older communication infrastructures where modern Ethernet-based panels cannot simply be used as direct replacements. For purchasing and maintenance departments, verifying the protocol, physical interface and project status is therefore more important than considering only the display size.
Can I migrate an existing OP7 or OP77A to an OP77B?
Yes, but not without verification. Siemens introduced the OP77B as the graphics-capable successor to the OP7, and the migration documentation specifically covers migration from OP7 to OP77B. This is helpful for retrofit projects because existing operating concepts can often be retained with reasonable effort. However, project conversion, communication profiles, function key assignments, alarm handling and data backup procedures should all be checked before implementation. Replacing a device without a reliable backup and without testing the runtime application is an unnecessary risk, particularly with obsolete panels.
How can I back up an OP77B project if the original source files are missing?
The OP77B supports backup and restore via MMC card and ProSave. Siemens describes the procedure both in the panel loader menu and through ProSave on the engineering PC. From a maintenance perspective, it is important to understand that without the original source files, a backup is generally most valuable for 1:1 restoration to the same device type. This point is also highlighted in specialist forums. Operators are therefore advised to back up working panels proactively before a failure occurs rather than searching for project data after a breakdown.
Which successor is suitable for an OP77B?
In the Siemens migration guide, the OP77B 6AV6641-0CA01-0AX1 is mapped to the KP400 Comfort 6AV2124-1DC01-0AX0. This provides useful guidance for modernisation projects but should not be interpreted as proof of a universal 1:1 replacement for every installed 0AX0 system. In practice, the operating concept, communication method, panel cut-out, power supply, project migration requirements and commissioning effort must all be evaluated. For productive legacy systems, the most economical approach is often to first stabilise operations through repair or exchange and then carry out a planned migration.