SIEMENS 6AG1505-0KA00-7AB0

  • EICHLER-art.no.: K0339228
  • EAN: 4042948655962
  • UPC: 887621830014

Product description

SIPLUS S7-1500 PS 1505 25W 24VD -25 ... +70 DEGEEES C WITH CONFORMAL COATING BASED ON 6ES7505-0KA00-0AB0 . SYSTEM POWER SUPPLY SUPPLIES THE OPERATING VOLTAGE THE S7-1500 VIA THE BACKPLANE B

Services for SIEMENS 6AG1505-0KA00-7AB0

Repair

2-5 days

from 373,07 €

to 570,57 €

Replacement

1-3 days

2 Pcs.

296,65 €

296,65 € *

Please enter an offer recipient here.


Used

1-3 days

2 Pcs.

329,61 €

329,61 € *

Please enter an offer recipient here.


New

Delivery information
Export identifier AL: N ECCN: EAR99H
Net weight 0.363
Quantity 1 Stück
Packaging quantity 1
Additional product information
Product status
EAN 4042948655962
UPC 887621830014
Static lot number 85044095
List indicator A&DSE/SIP ADD
Product group X0SN
Country of origin DE
Compliance with the substance restrictions according to RoHS directive Since: 20130225
Product classifications Version Classification
eClass 4 /
eClass 5.1 27-24-22-09
eClass 6.0 27-24-22-09
ETIM 3 /
ETIM 4 EC000599
ETIM 5 EC000599

Attribute Value
General information
Product type designation PS 25W 24VDC
based on 6ES7505-0KA00-0AB0
Engineering with
● STEP 7 TIA Portal configurable/integrated from version see entry ID: 109746275
Supply voltage
Rated value (DC) 24 V; SELV
permissible range, lower limit (DC) 19.2 V; Static 19.2 V, dynamic 18.5 V
permissible range, upper limit (DC) 28.8 V; Static 28.8 V, dynamic 30.2 V
Reverse polarity protection Yes
Short-circuit protection Yes
Mains buffering
● Mains/voltage failure stored energy time 20 ms
Input current
Rated value at 24 V DC 1.3 A
Output current
Short-circuit protection Yes
Power
Infeed power to the backplane bus 25 W; > +60 °C max. power input 12.5 W
Power loss
Power loss at nominal rating conditions 6.2 W
Interrupts/diagnostics/status information
Status indicator Yes
Potential separation
primary/secondary Yes
Isolation
Isolation tested with 707 V DC (type test)
EMC
Interference immunity against voltage surge
● Interference immunity on supply lines acc. to IEC 61000-4-5 Yes; ±1 kV (acc. to IEC 61000-4-5; 1995; surge symm.), ±2 kV (acc. to IEC 61000-4-5; 1995; surge asymm.), no external protective circuit required
Degree and class of protection
IP degree of protection IP20
Equipment protection class III, with protective conductor
Ambient conditions
Ambient temperature during operation
● min. -40 °C; = Tmin (incl. condensation/frost); start-up @ -25 °C
● max. 70 °C; = Tmax; for vertical mounting position Tmax = +40 °C
Ambient temperature during storage/transportation
● min. -40 °C
● max. 70 °C
Altitude during operation relating to sea level
● Installation altitude above sea level, max. 5 000 m
● Ambient air temperature-barometric pressure-altitude Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)
Relative humidity
● With condensation, tested in accordance with IEC 60068-2-38, max. 100 %; RH incl. condensation/frost (no commissioning under condensation conditions)
Resistance
Coolants and lubricants
— Resistant to commercially available coolants and lubricants Yes; Incl. diesel and oil droplets in the air
Use in stationary industrial systems
— to biologically active substances according to EN 60721-3-3 Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
— to chemically active substances according to EN 60721-3-3 Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-3 Yes; Class 3S4 incl. sand, dust, *
Use on ships/at sea
— to biologically active substances according to EN 60721-3-6 Yes; Class 6B2 mold and fungal spores (excluding fauna); Class 6B3 on request
— to chemically active substances according to EN 60721-3-6 Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-6 Yes; Class 6S3 incl. sand, dust; *
Usage in industrial process technology
— Against chemically active substances acc. to EN 60654-4 Yes; Class 3 (excluding trichlorethylene)
— Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04 Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)
Remark
— Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04 * The supplied plug covers must remain in place over the unused interfaces during operation!
Conformal coating
● Coatings for printed circuit board assemblies acc. to EN 61086 Yes; Class 2 for high reliability
● Protection against fouling acc. to EN 60664-3 Yes; Type 1 protection
● Military testing according to MIL-I-46058C, Amendment 7 Yes; Discoloration of coating possible during service life
● Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A Yes; Conformal coating, Class A
Dimensions
Width 35 mm
Height 147 mm
Depth 129 mm
Weights
Weight, approx. 350 g

Important documents

Repair accompanying note

Download the repair accompanying note as a PDF, or use the digital repair registration and send your defective modules to the EICHLER Service Centre for repair.

Laughing Eichler technician points to green PDF with special sale of automation technology

Your shopping basket

Loading shopping basket