SIEMENS 6ES7322-1FF01-0AA0

  • SIEMENS | PLC Controls | Digital Input / Output Modules

  • EICHLER-art.no.: K0118548
  • EAN: 4025515060994
  • UPC: 662643171433

Product description

SIMATIC S7-300, DIGITAL OUTPUT SM 322, ISOLATED, 8 DO, 120/230 V AC, 1 A, 1X 20-POLE

Services for SIEMENS 6ES7322-1FF01-0AA0

Repair

2-5 days

from 374,00 €

to 572,00 €

Replacement

1-3 days

1 Pcs.

356,40 €

267,30 €

267,30 € *

Please enter an offer recipient here.


Used

1-3 days

1 Pcs.

396,00 €

297,00 €

297,00 € *

Please enter an offer recipient here.


New

1-3 days

2 Pcs.

440,00 €

330,00 €

330,00 € *

Please enter an offer recipient here.


Delivery information
Export identifier AL: N ECCN: N
Net weight 0.294
Quantity 1 Stück
Packaging quantity 1
Additional product information
Product status
EAN 4025515060994
UPC 662643171433
Static lot number 85389091
List indicator ST73
Product group 4561
Country of origin DE
Compliance with the substance restrictions according to RoHS directive Since: 20051215
Product classifications Version Classification
eClass 4 27-24-03-04
eClass 5.1 27-24-22-04
eClass 6.0 27-24-22-04
ETIM 3 /
ETIM 4 EC001419
ETIM 5 EC001419

What is the 6ES7322-1FF01-0AA0 and where is it used?

The 6ES7322-1FF01-0AA0 is a SIMATIC S7-300 SM 322 digital output assembly from Siemens. The module provides 8 digital outputs for 120/230 V AC loads and is connected via a 20-pin front connector. It is typically used in existing installations where mains-voltage actuators need to be controlled by a PLC, such as contactors, motor starters, solenoid valves, fractional horsepower (FHP) motors and signal lamps. For maintenance personnel, the assembly is particularly important when an existing S7-300 system must be returned to service quickly. For procurement teams, the exact part number is essential to ensure that wiring, mechanical dimensions and electrical characteristics match the existing installation without requiring unnecessary modifications.

Overview of the key technical data and what it means

The assembly provides 8 outputs, features galvanic isolation, and divides the outputs into two groups of four channels. Siemens lists the module in its short description as 120/230 V AC, 1 A, although the detailed technical data specifies up to 2 A per output at 0 to 40 °C and 1 A per output at 40 to 60 °C. In practice, this means that the actual load capacity depends on ambient temperature, mounting position and the group current. Each group is subject to current limits and protected by an 8 A miniature fuse. Important diagnostic features include indications for fuse failure and missing load voltage, together with the PWR, FSG, SF and green channel status LEDs. The module requires a 20-pin front connector and has dimensions of 40 × 125 × 120 mm.

Product status, life-cycle status and obsolescence

Siemens currently classifies the 6ES7322-1FF01-0AA0 as a spare part. At the same time, Siemens defined the PM400 phase-out milestone for S7-300 / ET 200M components as 01 October 2023 and the PM410 product cancellation milestone as 01 October 2025. For operators of older installations, this increases the procurement risk in the event of an unexpected failure and highlights the need for a structured spare-parts strategy. No clearly identified direct 1:1 standard successor for this module was found in the reviewed Siemens documentation. However, Siemens offers the SIPLUS variant 6AG1322-1FF01-2AA0, which is based on this module and designed for extended environmental conditions. For modernisation projects, Siemens generally recommends using SiPortal successor searches and considering migration paths from S7-300 to S7-1500.

Available EICHLER services and when they are relevant

For the 6ES7322-1FF01-0AA0, EICHLER currently offers repair, exchange, used and new equipment options. Repair is particularly suitable when the existing assembly, wiring and engineering configuration should be retained as closely as possible to the original installation. EICHLER specifies a repair lead time of 2 to 5 days and describes the service as including technical cleaning, preventive maintenance, comprehensive functional testing and a minimum 24-month warranty. Exchange units, used equipment and new devices are available with lead times of approximately 1 to 3 days, making them particularly attractive when downtime costs exceed the difference between repair and replacement. For procurement departments and production managers, this combination of services provides valuable protection against obsolescence, unexpected failures and supply-chain constraints in ongoing operations.

Attribute Value
Supply voltage
Load voltage L1
● Rated value (AC) 230 V; 120/230 V AC
● permissible range, lower limit (AC) 93 V
● permissible range, upper limit (AC) 264 V
● permissible frequency range, lower limit 47 Hz
● permissible frequency range, upper limit 63 Hz
Input current
from load voltage L1 (without load), max. 2 mA
from backplane bus 5 V DC, max. 100 mA
Power loss
Power loss, typ. 8.6 W
Digital outputs
Number of digital outputs 8
Short-circuit protection Yes; Fuse 8 A, 250 V; per group
● required current for fuse shutdown, min. 40 A
● Response time, max. 300 ms
Controlling a digital input Yes
Size of motor starters according to NEMA, max. 5 NEMA compliant
Spare fuses 8 A / quick response
Zero-crossing switch Yes; Max. 60 V
Switching capacity of the outputs
● on lamp load, max. 50 W
Output voltage
● for signal "1", min. L1 (-1.5 V)
● for signal "1" (at max. current), min. L1 (-1.5 V)
● for signal "1" (at min. current), min. L1 (-8.5 V)
Output current
● for signal "1" rated value 2 A
● for signal "1" permissible range for 0 to 40 °C, min. 10 mA
● for signal "1" permissible range for 0 to 40 °C, max. 2 A
● for signal "1" permissible range for 40 to 60 °C, min. 10 mA
● for signal "1" permissible range for 40 to 60 °C, max. 1 A
● for signal "1" minimum load current 10 mA
● for signal "1" permissible surge current, max. 20 A; max. 1 AC cycle
● for signal "0" residual current, max. 2 mA
Output delay with resistive load
● "0" to "1", max. 1 AC cycle
● "1" to "0", max. 1 AC cycle
Parallel switching of two outputs
● for uprating No
● for redundant control of a load Yes
Switching frequency
● with resistive load, max. 10 Hz
● with inductive load, max. 0.5 Hz
● with inductive load (acc. to IEC 60947-5-1, AC15), max. 0.5 Hz
● on lamp load, max. 1 Hz
Total current of the outputs (per group)
horizontal installation
— up to 40 °C, max. 4 A
— up to 60 °C, max. 2 A
vertical installation
— up to 40 °C, max. 2 A
Cable length
● shielded, max. 1 000 m
● unshielded, max. 600 m
Interrupts/diagnostics/status information
Alarms No
Diagnostics function Yes; Fuse blown or load voltage missing
Alarms
● Diagnostic alarm No
Diagnoses
● Wire break No
● Short-circuit No
● Fuse blown Yes
● missing load voltage Yes
Diagnostics indication LED
● Rated load voltage PWR (green) Yes
● Fuse OK FSG (green) Yes
● Group error SF (red) Yes
● Status indicator digital output (green) Yes
Potential separation
Potential separation digital outputs
● between the channels Yes
● between the channels, in groups of 4
● between the channels and backplane bus Yes; Optocoupler
Isolation
Isolation tested with 1 500 V AC
Connection method
required front connector 20-pin
Dimensions
Width 40 mm
Height 125 mm
Depth 120 mm
Weights
Weight, approx. 275 g

Fault description Possible solution
Why is the red SF LED illuminated on the 6ES7322-1FF01-0AA0? On this module, the diagnostic function primarily indicates a blown fuse or missing load voltage. Therefore, first check the L1 load voltage, PWR/FSG indication, the 8 A fuse of the affected group and the wiring of the affected group of four channels. If the fault remains despite correct supply, the next points to check are the backplane bus contact, module seating and a possible module defect.
Why does an output not switch despite the PLC signal being set? First check whether an AC load voltage between 93 and 264 V is actually present and whether the connected load reaches the minimum load current of 10 mA. Also check the wiring and front connector, as the module uses a 20-pin connection. Siemens also refers to typical fault patterns such as missing load voltage or a defective fuse.
Why does the fuse of the output group keep tripping? Common causes include overload, wiring faults, inrush current peaks or unsuitable protection. Siemens specifies an 8 A miniature fuse per group, a required breaking current of at least 40 A in the event of a fuse trip, as well as limits for lamp load, surge current and total current per group. If several loads are combined on one group of four channels, the group load should be distributed correctly and the load type checked carefully.
Why does a lamp still glow slightly after switching off, or why does a contactor not drop out cleanly? The module uses electronic output technology, and Siemens specifies a residual current of up to 2 mA. This may become visible with very small, high-resistance or sensitive loads. In practice, it is useful to check the load type and, if necessary, use a more suitable load or an isolating switching stage if the behaviour is critical for the application.
Why is an entire group of four channels affected rather than only one individual channel? The outputs are arranged in groups of four channels, and the protection and diagnostic behaviour also follows this group-based structure. If the load voltage of one group fails or the group fuse trips, several channels are therefore affected at the same time.

Which front connector is suitable for the 6ES7322-1FF01-0AA0?

This module requires a 20-pin front connector. Siemens specifies, among others, the 6ES7392-1AJ00-0AA0 front connector with screw terminals and the 6ES7392-1BJ00-0AA0 front connector with spring-clamp terminals. This is important for both procurement and maintenance, as ordering the wrong connector variant can unnecessarily delay installation and commissioning.

Is the 6ES7322-1FF01-0AA0 still available as a new product or only as a spare part?

Siemens currently classifies the assembly as a spare part. However, according to the EICHLER product page, the module is still available through several procurement channels, including new, used, exchange and repair options. For operators, this is particularly valuable because it allows a choice between rapid availability, cost optimisation and the continued use of the existing assembly, depending on the urgency of the situation.

Why is the 6ES7322-1FF01-0AA0 specified as 1 A in some places and 2 A in others?

The Siemens short description identifies the module as 120/230 V AC, 1 A. However, the detailed technical data specifies up to 2 A per output at ambient temperatures of 0 to 40 °C, and 1 A per output at 40 to 60 °C. In practice, the actual permissible load therefore depends not only on the short specification but also on the ambient temperature, mounting conditions and group current loading within the control cabinet.

Can I also use the module in an ET 200M station?

Yes. Siemens describes the assembly as part of the S7-300 product family and identifies suitable IM153-2 interface modules and compatible successor interfaces for use within ET 200M distributed I/O systems. This is particularly relevant when an existing ET 200M station in the field needs to be repaired while maintaining the current I/O structure and engineering configuration.

Is there a direct successor to the 6ES7322-1FF01-0AA0?

No clearly defined direct 1:1 standard successor could be identified in the reviewed Siemens documentation. Siemens generally recommends using SiePortal successor searches and considering migration paths from S7-300 to S7-1500. For harsh environmental conditions, Siemens also documents a SIPLUS variant based on this module. For operators, this means that in the event of an unexpected failure, repair or spare-part procurement is usually the fastest solution, whereas a system migration is generally the more appropriate approach for planned modernisation projects.

Important documents

Repair accompanying note

Download the repair accompanying note as a PDF, or use the digital repair registration and send your defective modules to the EICHLER Service Centre for repair.

Laughing Eichler technician points to green PDF with special sale of automation technology

Quality & warranty

Outstanding service quality with every handle

Two Eichler technicians high-five each other after a successful repair

Your shopping basket

Loading shopping basket