SIEMENS 6NH7800-3CA00

  • EICHLER-art.no.: K0174241
  • EAN: 4019169144186
  • UPC: 662643195057

Product description

SINAUT ST7, TIM 3V-IE ADVANCED COMMUNICATION MODULE FOR SIMATIC S7-300 WITH A RS232-INTERFACE FOR SINAUT COMMUNICATION VIA A CLASSIC WAN AND A RJ45 INTERFACE FOR SINAUT COMMUNICATION VIA AN IP-BASED NETWORK (WAN OR LAN)

Services for SIEMENS 6NH7800-3CA00

Repair

2-5 days

from 1.139,85 €

to 1.676,25 €

per pc. 159,00 €

Replacement

Used

3-5 days

1 Pcs.

1.678,49 €

1.594,57 €

per pc. 159,00 €

1.594,57 € *

Please enter an offer recipient here.


New

Delivery information
Export identifier AL: N ECCN: N
Net weight 0.321
Quantity 1 Stück
Packaging quantity 1
Additional product information
Product status
EAN 4019169144186
UPC 662643195057
Static lot number 85176200
List indicator IK
Product group 2461
Country of origin DE
Compliance with the substance restrictions according to RoHS directive Since: 20070621
Product classifications Version Classification
eClass 4 27-24-03-09
eClass 5.1 27-24-22-08
eClass 6.0 27-24-22-08
ETIM 3 /
ETIM 4 EC001423
ETIM 5 EC001423

Attribute Value
product brand name SINAUT ST7
transfer rate
transfer rate
● for Industrial Ethernet 10 ... 100 Mbit/s
● according to RS 232 50 ... 38400 bit/s
interfaces
number of interfaces / according to Industrial Ethernet 1
number of electrical connections
● for external data transmission / according to RS 232 1
● for power supply 1
type of electrical connection
● of Industrial Ethernet interface RJ45 port
type of electrical connection
● at interface 1 / for external data transmission 9 pin Sub-D-connector (RS232)
● for power supply 2-pole plugable terminal block
design of the removable storage
● C-PLUG No
supply voltage, current consumption, power loss
type of voltage / of the supply voltage DC
supply voltage 24 V
supply voltage 20.4 ... 28.8 V
supply voltage / external / at DC / rated value 24 V
supply voltage / external / at DC / rated value 20.4 ... 28.8 V
relative symmetrical tolerance / at DC
● at 5 V 5 %
relative positive tolerance / at DC / at 24 V 5 %
relative negative tolerance / at DC / at 24 V 5 %
consumed current
● from backplane bus / at DC / at 24 V / maximum 0.2 A
● from external supply voltage / at DC / at 24 V / maximum 0.2 A
power loss [W] 5.8 W
product extension / optional / backup battery No
ambient conditions
ambient temperature
● during operation 0 ... 60 °C
● during storage -40 ... +70 °C
● during transport -40 ... +70 °C
relative humidity
● at 25 °C / without condensation / during operation / maximum 95 %
protection class IP IP20
design, dimensions and weights
module format Compact module S7-300 single width
width 40 mm
height 125 mm
depth 120 mm
net weight 0.25 kg
product features, product functions, product components / general
number of units
● note Number of TIMs per S7-300: multiple, number depends on the connection resources of the S7-300 CPU
wire length
● with RS 232 interface / maximum 6 m
performance data / S7 communication
number of possible connections / for S7 communication
● maximum 24
● with PG connections / maximum 4
● with OP connections / maximum 20
service
● SINAUT ST7 via S7 communication Yes
● PG/OP communication Yes
performance data / multi-protocol mode
number of active connections / with multi-protocol mode 24
performance data / telecontrol
suitability for use
● node station Yes
● substation Yes
● TIM control center Yes
● note RS232 and Industrial Ethernet can be operated in parallel
protocol / is supported
● DNP3 No
● SINAUT ST1 protocol Yes
● SINAUT ST7 protocol Yes
product function / data buffering if connection is aborted Yes; 32,000 data messages
storage capacity
● of S7 CPU work memory / for TD7onCPU mode data blocks on CPU / required 20 Kibyte
● of S7 CPU work memory / for TD7onTIM mode data blocks on TIM / required 0 Kibyte
● note TD7onCPU: at least 20 KB, actual requirement determined by data volume and functional scope TD7onTIM: 0 bytes in most favorable case
product feature / buffered message frame memory No
transmission format
● for SINAUT ST1 protocol with polling / 11 bit Yes
● for SINAUT ST1 protocol with spontaneous / 10-bit or 11-bit Yes
● for SINAUT ST7 protocol with multi-master polling / 10-bit Yes
● for SINAUT ST7 protocol with polling or spontaneous / 10-bit or 11-bit Yes
operating mode for scanning of data transmission
● with dedicated line/radio link / with SINAUT ST1 protocol Polling, polling with time slot procedure
● with dedicated line/radio link / with SINAUT ST7 protocol Polling, polling with time slot procedure, multi-master polling with time slot procedure
● with dial-up network / with SINAUT ST1 protocol spontaneous
● with dial-up network / with SINAUT ST7 protocol spontaneous
hamming distance
● for SINAUT ST1 protocol 4
● for SINAUT ST7 protocol 4
product functions / management, configuration, engineering
configuration software
● required SINAUT ST7 ES
● for CPU configuring / required / SINAUT TD7 block library for CPU Yes
● for PG configuring / required / SINAUT ST7 configuration software for PG Yes
storage location / of TIM configuration data on the TIM
product function / is supported / identification link Yes; acc. to IEC 61406-1:2022
product functions / security
operating mode / Virtual Private Network (VPN) Yes
type of authentication / with Virtual Private Network / PSK Yes
product function
● password protection for VPN Yes
● MSC client via GPRS modem with MSC capability Yes
protocol
● is supported / MSC protocol Yes
● with Virtual Private Network MSC / is supported TCP/IP
key length / for MSC / with Virtual Private Network 128 bit
number of possible connections
● as MSC client / with VPN connection 1
● as MSC server / with VPN connection 0
standards, specifications, approvals
certificate of suitability / CE marking Yes
certificate of suitability / UKCA marking Yes
certificate of suitability / KC approval Yes
certificate of suitability / Regulatory Compliance Mark (RCM) Yes
certificate of suitability / RoHS conformity Yes
standards, specifications, approvals / hazardous environments / header
certificate of suitability / ATEX Yes
certificate of suitability / IECEx Yes
certificate of suitability / ULhazloc approval Yes
certificate of suitability / CCC / for hazardous zone according to GB standard Yes
certificate of suitability / FM registration Yes