Product description
SIPLUS NET CP342-5 PROFIBUS -25 ... +70 DEGREES C BASED ON 6GK7342-5DA03-0XE0 . COMMUNICATIONPROCESSOR CP342-5 FOR CONNECTING SIMATIC S7-300 TO PROFIBUS, DP, S5-COMPATIBLE-, PG/OP- AND S7-COMMUNICATION
Services for SIEMENS 6AG1342-5DA03-7XE0
Repair
from 1.205,59 €
to 1.772,93 €
Replacement
1.597,76 €
1.517,87 €
Used
1.775,29 €
1.686,53 €
New
SIEMENS |
6AG1342-5DA03-7XE0 –
additional product information
| Delivery information | |||
|---|---|---|---|
| Export identifier | AL: N ECCN: N | ||
| Net weight | 0.339 | ||
| Quantity | 1 Stück | ||
| Packaging quantity | 1 | ||
| Additional product information | |||
|---|---|---|---|
| Product status | |||
| EAN | 4047618042318 | ||
| UPC | 887621029470 | ||
| Static lot number | 85176200 | ||
| List indicator | A&DSE/SIP ADD | ||
| Product group | 4395 | ||
| Country of origin | DE | ||
| Compliance with the substance restrictions according to RoHS directive | Since: 20140901 | ||
| Product classifications | Version | Classification | |
|---|---|---|---|
| eClass | 4 | / | |
| eClass | 5.1 | 27-24-22-08 | |
| eClass | 6.0 | 27-24-22-08 | |
| ETIM | 3 | / | |
| ETIM | 4 | EC001423 | |
| ETIM | 5 | EC001423 | |
| Attribute | Value |
|---|---|
| product brand name | SIPLUS |
| transfer rate | |
| transfer rate | |
| ● at the 1st interface / according to PROFIBUS | 9.6 kbit/s ... 12 Mbit/s |
| interfaces | |
| number of interfaces / according to Industrial Ethernet | 0 |
| number of electrical connections | |
| ● at the 1st interface / according to PROFIBUS | 1 |
| ● for power supply | 1 |
| type of electrical connection | |
| ● at the 1st interface / according to PROFIBUS | 9-pin Sub-D socket (RS485) |
| ● for power supply | 4-pole terminal block |
| supply voltage, current consumption, power loss | |
| type of voltage / of the supply voltage | DC |
| supply voltage / 1 / from backplane bus | 5 V |
| supply voltage / external | 24 V |
| relative positive tolerance / at DC / at 24 V | 20 % |
| relative negative tolerance / at DC / at 24 V | 15 % |
| consumed current | |
| ● from backplane bus / at DC / at 5 V / typical | 0.15 A |
| ● from external supply voltage / at DC / at 24 V / typical | 0.25 A |
| power loss [W] | 6.75 W |
| ambient conditions | |
| ambient temperature | |
| ● during operation | -25 ... +70 °C |
| ● during storage | -40 ... +70 °C |
| ● during transport | -40 ... +70 °C |
| installation altitude / at height above sea level / maximum | 5000 m |
| ambient condition / relating to ambient temperature - air pressure - installation altitude | Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m) |
| relative humidity | |
| ● with condensation / according to IEC 60068-2-38 / maximum | 100 %; RH including condensation/frost (no commissioning when condensation is present), horizontal installation |
| chemical resistance / to commercially available cooling lubricants | Yes; incl. airborne diesel and oil droplets |
| resistance to biologically active substances | |
| ● conformity according to EN 60721-3-3 | Yes; Class 3B2 mold and fungal spores (excluding fauna), Class 3B3 on request |
| ● conformity according to EN 60721-3-6 | Yes; Class 6B2 mold, fungal and dry rot spores (excluding fauna) |
| resistance to chemically active substances | |
| ● conformity according to EN 60721-3-3 | Yes; Class 3C4 (RH < 75 %) incl. salt spray in accordance with EN 60068-2-52 (Severity 3). The supplied plug covers must remain in place on the unused interfaces during operation. |
| ● conformity according to EN 60721-3-6 | Yes |
| resistance to mechanically active substances | |
| ● conformity according to EN 60721-3-3 | Yes; Class 3S4 incl. sand, dust. The supplied plug covers must remain in place over the unused interfaces during operation. |
| ● conformity according to EN 60721-3-6 | Yes; Class 6S3 incl. sand, dust. The supplied plug covers must remain in place over the unused interfaces during operation. |
| coating / for equipped printed circuit board / according to EN 61086 | Yes; Class 2 for high availability |
| type of coating / protection against pollution according to EN 60664-3 | Yes; Protection of the type 1 |
| type of test / of the coating / according to MIL-I-46058C | Yes; Coating discoloration during service life possible |
| product conformity / of the coating / Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A | Yes; Conformal coating, class A |
| protection class IP | IP20 |
| design, dimensions and weights | |
| module format | Compact module S7-300 single width |
| width | 40 mm |
| height | 125 mm |
| depth | 120 mm |
| net weight | 0.3 kg |
| product features, product functions, product components / general | |
| number of units | |
| ● per CPU / maximum | 4 |
| performance data / open communication | |
| number of possible connections / for open communication / by means of SEND/RECEIVE blocks / maximum | 16 |
| data volume | |
| ● as user data per connection / for open communication / by means of SEND/RECEIVE blocks / maximum | 240 byte |
| performance data / PROFIBUS DP | |
| service / as DP master | |
| ● DPV0 | Yes |
| number of DP devices | |
| ● on DP master / operable | 124 |
| data volume | |
| ● of the address range of the inputs / as DP master / total | 2160 byte |
| ● of the address range of the outputs / as DP master / total | 2160 byte |
| ● of the address range of the inputs / per DP device | 244 byte |
| ● of the address range of the outputs / per DP device | 244 byte |
| ● of the address range of the diagnostic data / per DP device | 240 byte |
| service / as DP device | |
| ● DPV0 | Yes |
| data volume | |
| ● of the address range of the inputs / as DP device / total | 240 byte |
| ● of the address range of the outputs / as DP device / total | 240 byte |
| performance data / S7 communication | |
| number of possible connections / for S7 communication | |
| ● maximum | 16 |
| performance data / multi-protocol mode | |
| number of active connections / with multi-protocol mode | |
| ● without DP / maximum | 32 |
| ● with DP / maximum | 28 |
| performance data / telecontrol | |
| protocol / is supported | |
| ● TCP/IP | No |
| product functions / management, configuration, engineering | |
| configuration software | |
| ● required | STEP 7 V5.1 SP2 or higher / STEP 7 Professional V12 (TIA Portal) or higher |