SIEMENS 6ES7332-8TF01-0AB0
-
SIEMENS | PLC Controls | Analog Input / Output Modules
- EICHLER-art.no.: K0219488
- EAN: 4025515075806
- UPC: 662643401462
Product description
SIMATIC DP, HART ANALOG OUTPUT, SM 332, 8 AO, 0/4 - 20 MA HART, FOR ET200M WITH IM153-2, IM 153-2, 20-POLE FUNCTIONS: FW UPDATE, HART AUXILIARY VARIABLES, REDUNDANCY, LOCAL DIAGNOSTIC BUFFER WITH TIME STAMPING,
Services for SIEMENS 6ES7332-8TF01-0AB0
Repair
from 660,50 €
to 1.188,89 €
Replacement
1.245,69 €
934,27 €
Used
1.747,15 €
1.310,36 €
New
2.266,00 €
1.699,50 €
SIEMENS |
6ES7332-8TF01-0AB0 –
additional product information
| Delivery information | |||
|---|---|---|---|
| Export identifier | AL: N ECCN: EAR99H | ||
| Net weight | 0.26 | ||
| Quantity | 1 Stück | ||
| Packaging quantity | 1 | ||
| Additional product information | |||
|---|---|---|---|
| Product status | |||
| EAN | 4025515075806 | ||
| UPC | 662643401462 | ||
| Static lot number | 85389091 | ||
| List indicator | ST73 | ||
| Product group | 4428 | ||
| Country of origin | DE | ||
| Compliance with the substance restrictions according to RoHS directive | Since: 20081231 | ||
| Product classifications | Version | Classification | |
|---|---|---|---|
| eClass | 4 | 27-24-03-05 | |
| eClass | 5.1 | 27-24-26-01 | |
| eClass | 6.0 | 27-24-26-01 | |
| ETIM | 3 | / | |
| ETIM | 4 | EC001596 | |
| ETIM | 5 | EC001596 | |
What is 6ES7332-8TF01-0AB0 and where is it used?
6ES7332-8TF01-0AB0 is a Siemens SIMATIC SM 332 HART analogue output module for ET 200M with IM153-2. The module provides eight analogue current outputs and is designed for 0/4…20 mA HART operation. It is typically used wherever intelligent field devices such as valve positioners, control valve actuators or other HART-capable actuators need to receive an analogue setpoint from the control system while also being integrated diagnostically. In ET 200M architectures, the system handles HART communication with the field device for tasks such as parameterisation, status monitoring and access to additional variables. This makes the module particularly attractive for process plants, retrofit projects and applications where traditional 4…20 mA technology is combined with the added functionality of HART.
Overview of the key technical data and what it means
The module operates from a 24 V DC load supply and provides eight current outputs supporting both 0…20 mA and 4…20 mA ranges. It offers a resolution of up to 16 bits including sign, with an effective resolution of 15 bits in the relevant current ranges. For users, this means highly accurate setpoint generation for precise control applications. The permissible load impedance is up to 750 Ω, while the maximum shielded cable length is 800 m, providing sufficient flexibility for most control cabinets and field wiring installations. The module also supports diagnostic functions, substitute values, diagnostic alarms, a local diagnostic buffer with time stamping and firmware updates. Its compact design measures 40 mm wide, 125 mm high and 117 mm deep and uses a 20-pin front connector.
Product status, lifecycle status and obsolescence
From a procurement perspective, Siemens lists 6ES7332-8TF01-0AB0 as a spare part, and the Siemens Portal shows the lifecycle status “Prod. Cancellation” for the product. Siemens has also documented the ET 200M phase-out roadmap, including phase-out announcement from 01 October 2023, product cancellation from 01 October 2025, product discontinuation from 01 October 2033 and end of lifecycle from 01 October 2035. For modernisation projects, Siemens references the ET 200SP HA module 6DL1135-6TF00-0PH1 as a functional migration target for this HART analogue output module. However, Siemens explicitly states that such comparison and upgrade documents do not constitute a general 1:1 compatibility guarantee. Therefore, every retrofit or migration project requires a detailed technical assessment of the application.
Available EICHLER services and when they are relevant in practice
For operators, maintenance teams and purchasing departments, 6ES7332-8TF01-0AB0 becomes particularly critical when a failure directly affects control valves, actuators or process-related HART communication. EICHLER offers repair, exchange, used and new units for this module. Repair is especially beneficial when the original module is to be returned to service within the existing system while also benefiting from technical cleaning, preventive maintenance, comprehensive functional testing and a minimum 24-month warranty. Exchange services are particularly useful when downtime costs are high and a form-fit-function replacement is required quickly. Used and new units provide additional flexibility for spare-parts stocking, emergency procurement and securing the long-term availability of older ET 200M installations even after the product has entered its phase-out lifecycle.
| Attribute | Value |
|---|---|
| General information | |
| Product function | |
| ● Isochronous mode No | |
| Supply voltage | |
| Load voltage L+ | |
| ● Rated value (DC) 24 V | |
| ● Reverse polarity protection Yes | |
| Input current | |
| from load voltage L+ (without load), max. 350 mA | |
| from backplane bus 5 V DC, max. 110 mA | |
| Power loss | |
| Power loss, typ. 6 W | |
| Analog outputs | |
| Number of analog outputs 8 | |
| Current output, no-load voltage, max. 24 V | |
| Output ranges, current | |
| ● 0 to 20 mA Yes | |
| ● -20 mA to +20 mA No | |
| ● 4 mA to 20 mA Yes | |
| Connection of actuators | |
| ● for current output two-wire connection Yes | |
| Load impedance (in rated range of output) | |
| ● with current outputs, max. 750 Ω | |
| ● with current outputs, inductive load, max. 10 mH | |
| Destruction limits against externally applied voltages and currents | |
| ● Voltages at the outputs towards MANA +60/-0.5 V | |
| Cable length | |
| ● shielded, max. 800 m | |
| Analog value generation for the outputs | |
| Integration and conversion time/resolution per channel | |
| ● Resolution with overrange (bit including sign), max. 16 bit | |
| ● Basic execution time of the module (all channels released) 10 ms; 10 ms in AO mode 50 ms in HART-AO mode | |
| Settling time | |
| ● for resistive load 0.1 ms | |
| ● for inductive load 0.5 ms | |
| Errors/accuracies | |
| Operational error limit in overall temperature range | |
| ● Current, relative to output range, (+/-) 0.2 % | |
| Basic error limit (operational limit at 25 °C) | |
| ● Current, relative to output range, (+/-) 0.1 % | |
| Interrupts/diagnostics/status information | |
| Diagnostics function Yes | |
| Substitute values connectable Yes | |
| Alarms | |
| ● Diagnostic alarm Yes | |
| Diagnostics indication LED | |
| ● Group error SF (red) Yes | |
| Potential separation | |
| Potential separation analog outputs | |
| ● between the channels No | |
| ● between the channels and backplane bus Yes | |
| ● Between the channels and load voltage L+ Yes | |
| Isolation | |
| Isolation tested with 500 V DC | |
| Degree and class of protection | |
| IP degree of protection IP20 | |
| Connection method | |
| required front connector 20-pin | |
| Dimensions | |
| Width 40 mm | |
| Height 125 mm | |
| Depth 117 mm | |
| Weights | |
| Weight, approx. 220 g |
| Fault description | Possible solution |
|---|---|
| Why does the 6ES7332-8TF01-0AB0 report a wire break even though the output is configured? | The module monitors current outputs diagnostically. First check the loop for actual interruptions, loose terminals, faulty actuators and missing 24 V load voltage. Siemens also points out that if the permitted load voltage range drops below 20.4 V and loads are high, the output currents may already collapse before the diagnostic message is clearly present. If the output current drops very sharply while wire-break diagnostics are active, the message may also remain until a plausible current loop is present again. |
| Why do I only read 7FFF hex or no valid readback value on the 6ES7332-8TF01-0AB0 channel? | The value 7FFF hex is a clear indication of an invalid readback state on this module. According to Siemens, it occurs if a channel is disabled or incorrectly assigned, if the module has not been configured correctly, if the 24 V load voltage is missing, or if a module fault is present. Therefore, check the hardware configuration, channel parameterisation, L+ supply voltage and the actual module status before looking for the fault in the process signal itself. |
| Why does HART communication with the 6ES7332-8TF01-0AB0 return faulty data or a first byte of 0? | Siemens describes a rare fault condition for firmware V3.1.1 with HART enabled, in which the first byte of a read data record may incorrectly appear as 0. If HART telegrams seem implausible or additional variables are not read correctly, the firmware version should therefore be checked and updated to V3.1.2 if necessary. This is particularly relevant in systems that use HART not only for basic operation but also for diagnostics and device parameterisation. |
| Why does an old analogue value remain at the output of the 6ES7332-8TF01-0AB0 after STOP to RUN? | Siemens describes that, for the module configured as 6ES7332-8TF01-0AB0, the outputs are not automatically reset during the transition from STOP to RUN. In practice, this may appear as though an old setpoint is “stuck”. Therefore, check the safety and restart strategy of your application, particularly substitute values, enable logic and the initialisation of output values in the user program. This point is process-critical for actuators and control loops. |
| Do unused channels on the 6ES7332-8TF01-0AB0 need to be terminated with resistors? | For unused outputs, no temporary loads should be installed simply to “terminate” the channel. Siemens points out that unused output channels should be disabled in STEP 7 via the parameter block. If a channel is properly disabled and not incorrectly wired, unnecessary diagnostics and misinterpretations during commissioning can be avoided. |
What is 6ES7332-8TF01-0AB0 used for?
The module is used for analogue current outputs with HART support in ET 200M stations. Typical applications include valve positioners, control valve actuators and other intelligent field devices that require not only a 0/4…20 mA setpoint signal but also HART-based diagnostics and parameterisation. This makes the module particularly suitable for process-industry installations where conventional analogue control technology and digital diagnostic information need to be combined.
Which signals does 6ES7332-8TF01-0AB0 support?
The module supports 0…20 mA and 4…20 mA current outputs with HART functionality. For purchasers and engineers, this is important because it allows integration of typical process instrumentation using standardised current-loop signals. The HART capability extends simple setpoint output with additional communication and diagnostic functions, such as device status monitoring and access to extended process variables.
Which technical specifications are most important for system design?
Key design parameters include the 24 V DC load supply, maximum load impedance of 750 Ω, eight output channels, shielded cable lengths up to 800 m, and the integrated diagnostic and substitute-value functions. In practice, this means that before replacing or purchasing the module, the wiring, power supply, front connector and actual field load should be checked to ensure that the replacement is mechanically, electrically and functionally compatible.
Is there a successor for 6ES7332-8TF01-0AB0?
For modernisation and migration projects, Siemens maps the functionality of this module to the ET 200SP HA module 6DL1135-6TF00-0PH1. This provides valuable guidance for lifecycle management and retrofit planning. However, Siemens explicitly states in its comparison documents that this should not be interpreted as an automatic 1:1 replacement for every installation. Before migration, channel diagnostics, wiring, HART requirements and the overall system architecture should always be evaluated carefully.
Can 6ES7332-8TF01-0AB0 still be economically purchased, repaired or exchanged?
Yes. Because the product is now primarily positioned within the spare-parts and phase-out environment, repair, exchange, used and new units are often more economical than an immediate platform migration. This is particularly true when a plant must be returned to service quickly, qualified legacy hardware is required or a retrofit project is planned for a later stage. EICHLER already offers these procurement and service options specifically for this part number.
Does 6ES7332-8TF01-0AB0 support firmware updates?
Yes. The module supports firmware updates, and Siemens explicitly references the HART modules 6ES7331-7TF01-0AB0 and 6ES7332-8TF01-0AB0 in connection with firmware updates via the hardware configuration. At the same time, Siemens notes that firmware updates are not possible in certain redundant operating modes. For operators, this means that the specific system architecture should always be reviewed before planning and performing a firmware update.