Product description

SIMATIC S7-300, ANALOG INPUT SM 331, ISOLATED, 8 AI; +/-5/10V, 1-5 V, +/-20 MA, 0/4 TO 20 MA, 16 BIT, SINGLE ROOTING (60 V COM.), 4-CHANNEL OPERATION: 10 MS, 8-CHANNEL OPERATION: 23-95MS, 1X 40-POLE

Services for SIEMENS 6ES7331-7NF10-0AB0

Repair

2-5 days

from 553,67 €

to 996,60 €

per pc. 159,00 €

Replacement

Used

3-5 days

10+ Pcs.

1.245,43 €

934,07 €

per pc. 159,00 €

934,07 € *

Please enter an offer recipient here.


New

Delivery information
Export identifier AL: N ECCN: EAR99H
Net weight 0.326
Quantity 1 Stück
Packaging quantity 1
Additional product information
Product status
EAN 4019169350716
UPC 662643177985
Static lot number 85389091
List indicator ST73
Product group 4561
Country of origin DE
Compliance with the substance restrictions according to RoHS directive Since: 20080331
Product classifications Version Classification
eClass 4 27-24-03-05
eClass 5.1 27-24-22-01
eClass 6.0 27-24-22-01
ETIM 3 /
ETIM 4 EC001420
ETIM 5 EC001420

Attribute Wert
General information
Product function
● Isochronous mode No
Supply voltage
Load voltage L+
● Rated value (DC) 24 V
● Reverse polarity protection Yes
Input current
from load voltage L+ (without load), max. 200 mA
from backplane bus 5 V DC, max. 100 mA
Power loss
Power loss, typ. 3 W
Analog inputs
Number of analog inputs 8
permissible input voltage for voltage input (destruction limit), max. 75 V; 35 V continuous, 75 V for max. 1 s (mark to space ratio 1:20)
permissible input current for current input (destruction limit), max. 40 mA
Input ranges
● Voltage Yes
● Current Yes
● Thermocouple No
● Resistance thermometer No
● Resistance No
Input ranges (rated values), voltages
● 0 to +10 V No
● 1 V to 5 V Yes
— Input resistance (1 V to 5 V) 10 MΩ
● 1 V to 10 V No
● -1 V to +1 V No
● -10 V to +10 V Yes
— Input resistance (-10 V to +10 V) 10 MΩ
● -2.5 V to +2.5 V No
● -250 mV to +250 mV No
● -5 V to +5 V Yes
— Input resistance (-5 V to +5 V) 10 MΩ
● -50 mV to +50 mV No
● -500 mV to +500 mV No
● -80 mV to +80 mV No
Input ranges (rated values), currents
● 0 to 20 mA Yes
— Input resistance (0 to 20 mA) 250 Ω
● -10 mA to +10 mA No
● -20 mA to +20 mA Yes
— Input resistance (-20 mA to +20 mA) 250 Ω
● -3.2 mA to +3.2 mA No
● 4 mA to 20 mA Yes
— Input resistance (4 mA to 20 mA) 250 Ω
Input ranges (rated values), thermocouples
● type B No
● type C No
● Type E No
● Type J No
● Type K No
● Type L No
● Type N No
● Type R No
● Type S No
● Type T No
● Type U No
● Type TXK/TXK(L) to GOST No
Input ranges (rated values), resistance thermometer
● Cu 10 No
● Ni 100 No
● Ni 1000 No
● LG-Ni 1000 No
● Ni 120 No
● Ni 200 No
● Ni 500 No
● Pt 100 No
● Pt 1000 No
● Pt 200 No
● Pt 500 No
Input ranges (rated values), resistors
● 0 to 150 ohms No
● 0 to 300 ohms No
● 0 to 600 ohms No
● 0 to 6000 ohms No
Cable length
● shielded, max. 200 m
Analog value generation for the inputs
Integration and conversion time/resolution per channel
● Resolution with overrange (bit including sign), max. 16 bit; Unipolar: 15/15/15/15 bit; bipolar: 15 bit + sign/15 bit + sign/15 bit + sign/15 bit + sign
● Integration time, parameterizable Yes; 23 / 72 / 83 / 95 ms
● Basic conversion time (ms) 10 ms (4-channel mode); 95/83/72/23 ms (8-channel mode)
● Interference voltage suppression for interference frequency f1 in Hz 400 / 60 / 50 Hz, combinations of 400, 60, 50 Hz
Encoder
Connection of signal encoders
● for voltage measurement Yes
● for current measurement as 2-wire transducer Yes; with external transmitter, current supply; possible with separate supply for transmitter
● for current measurement as 4-wire transducer Yes
Errors/accuracies
Operational error limit in overall temperature range
● Voltage, relative to input range, (+/-) 0.1 %
● Current, relative to input range, (+/-) 0.1 %
Basic error limit (operational limit at 25 °C)
● Voltage, relative to input range, (+/-) 0.05 %
● Current, relative to input range, (+/-) 0.05 %
Interrupts/diagnostics/status information
Diagnostics function Yes; Parameterizable
Alarms
● Diagnostic alarm Yes; Parameterizable
● Limit value alarm Yes; Parameterizable all channels (end of cycle interrupt is also supported across modules)
● Hardware interrupt Yes; Parameterizable, channels 0 to 7 (on exceeding limit value), at end of cycle
Diagnoses
● Diagnostic information readable Yes
Diagnostics indication LED
● Group error SF (red) Yes
Potential separation
Potential separation analog inputs
● between the channels Yes
● between the channels, in groups of 2
● between the channels and backplane bus Yes
● between the channels and the power supply of the electronics Yes
Isolation
Isolation tested with 500 V AC
Connection method
required front connector 40-pin
Dimensions
Width 40 mm
Height 125 mm
Depth 117 mm
Weights
Weight, approx. 272 g