SIEMENS 6ES7136-6AA00-0CA1

  • EICHLER-art.no.: K1161632
  • EAN: 4047623408031

Product description

SIMATIC DP, ELECTRONIC MODULE ET 200SP, F-AI 4XI0(4)..20 MA HF FAIL-SAFE ANALOG INPUTS UP TO PL E (ISO 13849) UP TO SIL 3 (IEC 61508)

Services for SIEMENS 6ES7136-6AA00-0CA1

Repair

2-5 days

from 513,19 €

to 784,88 €

Replacement

Used

New

1-3 days

2 Pcs.

431,25 €

409,69 €

409,69 € *

Please enter an offer recipient here.


Delivery information
Export identifier AL: N ECCN: EAR99H
Net weight 0.058
Quantity 1 Stück
Packaging quantity 1
Additional product information
Product status
EAN 4047623408031
UPC /
Static lot number 85389091
List indicator ST76
Product group 4527
Country of origin DE
Compliance with the substance restrictions according to RoHS directive Since: 20180703
Product classifications Version Classification
eClass 4 /
eClass 5.1 27-24-26-01
eClass 6.0 27-24-26-01
ETIM 3 /
ETIM 4 /
ETIM 5 EC001596

Attribute Value
General information
Product type designation F-AI 4xI 0(4)..20mA 2-/4-wire HF
Firmware version
● FW update possible Yes
usable BaseUnits BU type A0, A1
Color code for module-specific color-coded label CC00
Product function
● I&M data Yes; I&M0 to I&M3
Engineering with
● STEP 7 TIA Portal configurable/integrated from version V15 with HSP 203
CiR - Configuration in RUN
Reparameterization possible in RUN No
Calibration possible in RUN No
Supply voltage
Rated value (DC) 24 V
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V
Reverse polarity protection Yes
power supply according to NEC Class 2 required No
Input current
Current consumption (rated value) 0.38 A
Current consumption, max. 0.4 A
Encoder supply
24 V encoder supply
● 24 V Yes; min. L+ (-1.5 V)
● Short-circuit protection Yes
● Output current, max. 300 mA; total current of all encoders/channels
Power
Power consumption from the backplane bus 70 mW
Power loss
Power loss, typ. 2 W
Address area
Address space per module
● Inputs 14 byte; S7-300/400F CPU, 13 byte
● Outputs 5 byte; S7-300/400F CPU, 4 byte
Hardware configuration
Automatic encoding Yes
● Electronic coding element type F Yes
Analog inputs
Number of analog inputs 4
● For current measurement 4
permissible input current for current input (destruction limit), max. 35 mA
Input ranges (rated values), currents
● 0 to 20 mA Yes
— Input resistance (0 to 20 mA) 125 Ω
● 4 mA to 20 mA Yes
— Input resistance (4 mA to 20 mA) 125 Ω
Cable length
● shielded, max. 1 000 m
Analog value generation for the inputs
Measurement principle Sigma Delta
Integration and conversion time/resolution per channel
● Resolution with overrange (bit including sign), max. 16 bit
● Integration time, parameterizable Yes
● Integration time (ms) 20 / 16,667
● Interference voltage suppression for interference frequency f1 in Hz 50 / 60 Hz
Smoothing of measured values
● Number of smoothing levels 7
● parameterizable Yes
● Step: None Yes; 1x conversion cycle time
● Step: low Yes; 2x / 4x conversion cycle time
● Step: Medium Yes; 8x / 16x conversion cycle time
● Step: High Yes; 32x / 64x conversion cycle time
Encoder
Connection of signal encoders
● for current measurement as 2-wire transducer Yes
— Burden of 2-wire transmitter, max. 650 Ω
● for current measurement as 4-wire transducer Yes
Errors/accuracies
Linearity error (relative to input range), (+/-) 0.1 %
Temperature error (relative to input range), (+/-) 0.023 %/K
Repeat accuracy in steady state at 25 °C (relative to input range), (+/-) 0.1 %
Operational error limit in overall temperature range
● Current, relative to input range, (+/-) 2 %
Basic error limit (operational limit at 25 °C)
● Current, relative to input range, (+/-) 0.1 %
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency
● Series mode interference (peak value of interference < rated value of input range), min. 40 dB
● Common mode interference, min. 70 dB
Interrupts/diagnostics/status information
Diagnostics function Yes
Alarms
● Diagnostic alarm Yes
● Limit value alarm No
Diagnoses
● Monitoring the supply voltage Yes
● Wire break Yes
● Short-circuit Yes
Diagnostics indication LED
● RUN LED Yes; green LED
● ERROR LED Yes; red LED
● Monitoring of the supply voltage (PWR-LED) Yes; green PWR LED
● Channel status display Yes; green LED
● for channel diagnostics Yes; red LED
● for module diagnostics Yes; green/red DIAG LED
Potential separation
Potential separation channels
● between the channels No
● between the channels and backplane bus Yes
● between the channels and the power supply of the electronics Yes
Permissible potential difference
between the inputs (UCM) 10 Vpp
Isolation
Isolation tested with 707 V DC (type test)
Standards, approvals, certificates
Ecological footprint
● environmental product declaration Yes
Global warming potential
— global warming potential, (total) [CO2 eq] 88.3 kg
— global warming potential, (during production) [CO2 eq] 13.1 kg
— global warming potential, (during operation) [CO2 eq] 76.6 kg
— global warming potential, (after end of life cycle) [CO2 eq] -1.37 kg
Highest safety class achievable in safety mode
● Performance level according to ISO 13849-1 PLe
● Category according to ISO 13849-1 Cat. 4
● SIL acc. to IEC 61508 SIL 3
Probability of failure (for service life of 20 years and repair time of 100 hours)
— Low demand mode: PFDavg in accordance with SIL3 < 5.00E-05
— High demand/continuous mode: PFH in accordance with SIL3 < 1.00E-09 1/h
Ambient conditions
Ambient temperature during operation
● horizontal installation, min. 0 °C
● horizontal installation, max. 60 °C
● vertical installation, min. 0 °C
● vertical installation, max. 50 °C
Dimensions
Width 15 mm
Height 73 mm
Depth 58 mm
Weights
Weight, approx. 48 g

Important documents

Repair accompanying note

Download the repair accompanying note as a PDF, or use the digital repair registration and send your defective modules to the EICHLER Service Centre for repair.

Laughing Eichler technician points to green PDF with special sale of automation technology

Your shopping basket

Loading shopping basket