| General information |
|
| Product type designation |
AI 8xI 2-/4-wire BA |
| HW functional status |
FS23 or higher |
| Firmware version |
V2.0.0 |
| ● FW update possible |
Yes |
| usable BaseUnits |
BU type A0, A1 |
| Color code for module-specific color-coded label |
CC01 |
| Product function |
|
| ● I&M data |
Yes; I&M0 to I&M3 |
| ● Isochronous mode |
No |
| ● Measuring range scalable |
No |
| Engineering with |
|
| ● STEP 7 TIA Portal configurable/integrated from version |
TIA Portal V21 |
| ● STEP 7 configurable/integrated from version |
V5.7 SP3 |
| ● PROFIBUS from GSD version/GSD revision |
One GSD file each, Revision 3 and 5 and higher |
| ● PROFINET from GSD version/GSD revision |
GSDML V2.45 |
| Operating mode |
|
| ● Oversampling |
No |
| ● MSI |
No |
| CiR - Configuration in RUN |
|
| Reparameterization possible in RUN |
No |
| Calibration possible in RUN |
No |
| Supply voltage |
|
| Rated value (DC) |
24 V |
| permissible range, lower limit (DC) |
19.2 V |
| permissible range, upper limit (DC) |
28.8 V |
| Reverse polarity protection |
Yes |
| Input current |
|
| Current consumption (rated value) |
25 mA; rated voltage, all channels active, no load |
| Current consumption, max. |
725 mA; worst case voltage, all channels active, max. load, no derating |
| Encoder supply |
|
| 24 V encoder supply |
|
| ● 24 V |
Yes |
| ● Short-circuit protection |
Yes |
| ● Output current, max. |
0.7 A; total current of all encoders/channels |
| Power loss |
|
| Power loss, typ. |
0.7 W; rated voltage, 50 % active channels, 50 % of range |
| Address area |
|
| Address space per module |
|
| ● Address space per module, max. |
16 byte |
| Hardware configuration |
|
| Automatic encoding |
Yes |
| ● Mechanical coding element |
Yes |
| ● Type of mechanical coding element |
Type A |
| Selection of BaseUnit for connection variants |
|
| ● 1-wire connection |
BU type A0, A1 |
| ● 2-wire connection |
BU type A0, A1 |
| ● 4-wire connection |
BU type A0, A1 + potential distributor module |
| Analog inputs |
|
| Number of analog inputs |
8; Single-ended |
| ● For current measurement |
8 |
| permissible input current for current input (destruction limit), max. |
50 mA |
| Cycle time (all channels), min. |
1 ms; per channel |
| Input ranges (rated values), currents |
|
| ● 0 to 20 mA |
Yes |
| — Input resistance (0 to 20 mA) |
100 Ω; 15 bit |
| ● -20 mA to +20 mA |
Yes |
| — Input resistance (-20 mA to +20 mA) |
100 Ω; 16 bit incl. sign |
| ● 4 mA to 20 mA |
Yes |
| — Input resistance (4 mA to 20 mA) |
100 Ω; 15 bit |
| Cable length |
|
| ● shielded, max. |
200 m |
| Analog value generation for the inputs |
|
| Integration and conversion time/resolution per channel |
|
| ● Resolution with overrange (bit including sign), max. |
16 bit |
| ● Integration time, parameterizable |
Yes |
| ● Interference voltage suppression for interference frequency f1 in Hz |
16.67 / 50 / 60 / 4 800 (16.67 / 50 / 60) |
| ● Conversion time (per channel) |
180 / 60 / 50 / 0.625 (67.5 / 22.5 / 18.75) ms |
| Smoothing of measured values |
|
| ● Number of smoothing levels |
4 |
| ● Parameterizable |
Yes |
| ● Step: None |
Yes |
| ● Step: low |
Yes; 4x smoothing |
| ● Step: Medium |
Yes; 8x smoothing |
| ● Step: High |
Yes; 16x smoothing |
| Encoder |
|
| Connection of signal encoders |
|
| ● for voltage measurement |
No |
| ● for current measurement as 2-wire transducer |
Yes |
| — Burden of 2-wire transmitter, max. |
650 Ω |
| ● for current measurement as 4-wire transducer |
Yes |
| Errors/accuracies |
|
| Linearity error (relative to input range), (+/-) |
0.01 % |
| Temperature error (relative to input range), (+/-) |
0.005 %/K |
| Crosstalk between the inputs, min. |
50 dB |
| Repeat accuracy in steady state at 25 °C (relative to input range), (+/-) |
0.05 % |
| Operational error limit in overall temperature range |
|
| ● Current, relative to input range, (+/-) |
0.5 % |
| Basic error limit (operational limit at 25 °C) |
|
| ● Current, relative to input range, (+/-) |
0.3 % |
| Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency |
|
| ● Series mode interference (peak value of interference < rated value of input range), min. |
70 dB; With conversion time 67.5 / 22.5 / 18.75 ms: 40 dB |
| Interrupts/diagnostics/status information |
|
| Diagnostics function |
Yes |
| Alarms |
|
| ● Diagnostic alarm |
Yes |
| ● Limit value alarm |
No |
| Diagnoses |
|
| ● Monitoring the supply voltage |
Yes |
| ● Wire break |
Yes; at 4 to 20 mA |
| ● short-circuit |
Yes; Sensor supply to M; module by module |
| ● Group error |
Yes |
| ● Overflow/Underflow |
Yes; module-wise |
| Diagnostics indication LED |
|
| ● Monitoring of the supply voltage (PWR-LED) |
Yes; green LED |
| ● Channel status display |
Yes; green LED |
| ● for channel diagnostics |
No |
| ● for module diagnostics |
Yes; green/red DIAG LED |
| Potential separation |
|
| Potential separation channels |
|
| ● between the channels |
No |
| ● between the channels and backplane bus |
Yes |
| ● between the channels and the power supply of the electronics |
No |
| Isolation |
|
| Isolation tested with |
707 V DC (type test) |
| Standards, approvals, certificates |
|
| Ecological footprint |
|
| ● environmental product declaration |
Yes |
| Global warming potential |
|
| — global warming potential, (total) [CO2 eq] |
9.32 kg |
| — global warming potential, (during production) [CO2 eq] |
4.97 kg |
| — global warming potential, (during operation) [CO2 eq] |
4.79 kg |
| — global warming potential, (after end of life cycle) [CO2 eq] |
-0.449 kg |
| Security |
|
| signed firmware update |
Yes; firmware V2.0.0 or higher |
| safely removing data |
Yes; firmware V2.0.0 or higher |
| data integrity |
Yes; firmware V2.0.0 or higher |
| Ambient conditions |
|
| Ambient temperature during operation |
|
| ● horizontal installation, min. |
-30 °C; < 0 °C as of FS04 |
| ● horizontal installation, max. |
60 °C |
| ● vertical installation, min. |
-30 °C; < 0 °C as of FS04 |
| ● vertical installation, max. |
50 °C |
| Altitude during operation relating to sea level |
|
| ● Installation altitude above sea level, max. |
5 000 m; restrictions for installation altitudes > 2 000 m, see ET 200SP system manual |
| Absolute humidity |
|
| ● dew point, min. |
-60 °C; suitable for dry room applications |
| Dimensions |
|
| Width |
15 mm |
| Height |
73 mm |
| Depth |
58 mm |
| Weights |
|
| Weight, approx. |
31 g |