SIEMENS 6ES7134-4NB51-0AB0

  • EICHLER-art.no.: K0171103
  • EAN: 4025515073093
  • UPC: 662643231335

Product description

SIMATIC DP, ELECTRONIC MODULE ET 200S: 2AI RTD HIGH FEATURE, 15 MM WIDTH, 15BIT + SIGN ACCURACY +/- 0.1%, FOR 2-/3-/-4- WIRE SENSORS, WITH INTERNAL COMPENSATION OF THE WIRE RESISTOR, WITH LED SF (GROUP FAULT)

Services for SIEMENS 6ES7134-4NB51-0AB0

Repair

2-5 days

from 402,80 €

to 616,04 €

Replacement

Used

New

1-3 days

4 Pcs.

296,18 €

281,37 €

281,37 € *

Please enter an offer recipient here.


Delivery information
Export identifier AL: N ECCN: EAR99H
Net weight 0.044
Quantity 1 Stück
Packaging quantity 1
Additional product information
Product status EOP: 2023-10-01
EAN 4025515073093
UPC 662643231335
Static lot number 85389091
List indicator ST76
Product group 4467
Country of origin DE
Compliance with the substance restrictions according to RoHS directive Since: 20081231
Product classifications Version Classification
eClass 4 27-24-21-04
eClass 5.1 27-24-26-01
eClass 6.0 27-24-26-01
ETIM 3 /
ETIM 4 EC001596
ETIM 5 EC001596

Attribute Value
General information
Product function
● Isochronous mode No
Supply voltage
Load voltage L+
● Rated value (DC) 24 V; From power module
● Reverse polarity protection Yes
Input current
from load voltage L+ (without load), max. 30 mA
from backplane bus 3.3 V DC, max. 10 mA
Power loss
Power loss, typ. 0.6 W
Address area
Address space per module
● Address space per module, max. 4 byte
Analog inputs
Number of analog inputs 2
permissible input voltage for voltage input (destruction limit), max. 9 V
Constant measurement current for resistance-type transmitter, typ. 1.25 mA
Cycle time (all channels) max. Number of active channels per module x basic conversion time
Technical unit for temperature measurement adjustable Yes
Input ranges (rated values), resistance thermometer
● Cu 10 Yes
— Input resistance (Cu 10) 10 MΩ
● Ni 100 Yes
— Input resistance (Ni 100) 10 MΩ
● Ni 1000 Yes
— Input resistance (Ni 1000) 10 MΩ
● Ni 120 Yes
— Input resistance (Ni 120) 10 MΩ
● Ni 200 Yes
— Input resistance (Ni 200) 10 MΩ
● Ni 500 Yes
— Input resistance (Ni 500) 10 MΩ
● Pt 100 Yes
— Input resistance (Pt 100) 10 MΩ
● Pt 1000 Yes
— Input resistance (Pt 1000) 10 MΩ
● Pt 200 Yes
— Input resistance (Pt 200) 10 MΩ
● Pt 500 Yes
— Input resistance (Pt 500) 10 MΩ
Input ranges (rated values), resistors
● 0 to 150 ohms Yes
— Input resistance (0 to 150 ohms) 10 MΩ
● 0 to 300 ohms Yes
— Input resistance (0 to 300 ohms) 10 MΩ
● 0 to 600 ohms Yes
— Input resistance (0 to 600 ohms) 10 MΩ
● 0 to 3000 ohms Yes
— Input resistance (0 to 3000 ohms) 10 MΩ
Thermocouple (TC)
Temperature compensation
— internal temperature compensation Yes
Characteristic linearization
● Parameterizable Yes; for Ptxxx, Nixxx
— for resistance thermometer Ptxxx, Nixxx
Cable length
● shielded, max. 200 m
Analog value generation for the inputs
Measurement principle integrating (Sigma-Delta)
Integration and conversion time/resolution per channel
● Resolution with overrange (bit including sign), max. 16 bit; for Pt100, Ni100, Ni120, Pt200, Ni200, Pt500, Ni500, Pt1000, Ni1000, Cu10: 15 bit + sign; for 150, 300, 600, 3 000 ohms: 15 bit; for PTC: 1 bit
● Integration time (ms) 16,7 / 20 ms
● Interference voltage suppression for interference frequency f1 in Hz 50 / 60 Hz
● Conversion time (per channel) Basic conversion time incl. integration time: 50 / 60 ms; additional conversion time for diagnostics of wire break test: 5 / 5 ms; additional conversion time for line compensation with 3-wire connection: 50 / 60 ms
Smoothing of measured values
● parameterizable Yes; In four stages by means of digital filtering
● Step: None Yes; 1x cycle time
● Step: low Yes; 4x cycle time
● Step: Medium Yes; 32x cycle time
● Step: High Yes; 64x cycle time
Encoder
Connection of signal encoders
● for resistance measurement with two-wire connection Yes
● for resistance measurement with three-wire connection Yes; internal compensation of the line resistances
● for resistance measurement with four-wire connection Yes
Errors/accuracies
Operational error limit in overall temperature range
● Resistance thermometer, relative to input range, (+/-) Resistance-type transmitter: ±0.1 %; Pt100, Pt200, Pt500, Pt1000 standard: ±1.0 K; Pt100, Pt200, Pt500, Pt1000 climate: ±0.25 K; Ni100, Ni120, Ni200, Ni500, Ni1000 standard and climate: ±0.4 K; Cu10 ±1.5 K
Basic error limit (operational limit at 25 °C)
● Resistance thermometer, relative to input range, (+/-) Resistance-type transmitter: ±0.05 %; Pt100, Pt200, Pt500, Pt1000 standard: ±0.6 K; Pt100, Pt200, Pt500, Pt1000 climate: ±0.13 K; Ni100, Ni120, Ni200, Ni500, Ni1000 standard and climate: ±0.2 K; Cu10 ±1 K
Interrupts/diagnostics/status information
Diagnoses
● Wire break Yes
● Group error Yes
● Overflow/Underflow Yes
Diagnostics indication LED
● Group error SF (red) Yes
Parameter
Remark 7 byte
Diagnostics wire break Disable / enable
Group diagnostics Disable / enable
Overflow/Underflow Disable / enable
Potential separation
Potential separation analog inputs
● between the channels No
● between the channels and backplane bus Yes
● Between the channels and load voltage L+ Yes
Isolation
Isolation tested with 500 V DC
Dimensions
Width 15 mm
Height 81 mm
Depth 52 mm
Weights
Weight, approx. 40 g

Important documents

Repair accompanying note

Download the repair accompanying note as a PDF, or use the digital repair registration and send your defective modules to the EICHLER Service Centre for repair.

Laughing Eichler technician points to green PDF with special sale of automation technology

Your shopping basket

Loading shopping basket