SIEMENS 6AV3688-3EH47-0AX0

  • EICHLER-art.no.: K0316481
  • EAN: 4025515080350
  • UPC: 040892914832

Product description

SIMATIC HMI KP32F PN, KEY PANEL, 32 SHORT-STROKE KEYS WITH MULTI-COLORED LEDS, PROFINET INTERFACES WITH PROFISAFE, 16 DI+16 DI/DO, 4 SAFETY DI PINS, 24 V DC CAN BE LOOPED THROUGH PARAMETERIZABLE AS OF STEP 7 V5.5

Services for SIEMENS 6AV3688-3EH47-0AX0

Repair

1-3 days

from 734,78 €

to 1.322,60 €

Replacement

1-3 days

1 Pcs.

960,45 €

960,45 € *

Please enter an offer recipient here.


Used

1-3 days

1 Pcs.

1.067,17 €

1.067,17 € *

Please enter an offer recipient here.


New

1-3 days

1 Pcs.

1.420,00 €

1.420,00 € *

Please enter an offer recipient here.


Delivery information
Export identifier AL: N ECCN: EAR99H
Net weight 1.871
Quantity 1 Stück
Packaging quantity 1
Additional product information
Product status
EAN 4025515080350
UPC 040892914832
Static lot number 85371091
List indicator ST80.1A
Product group 3406
Country of origin DE
Compliance with the substance restrictions according to RoHS directive Since: 20111118
Product classifications Version Classification
eClass 4 /
eClass 5.1 27-24-23-05
eClass 6.0 27-24-23-05
ETIM 3 /
ETIM 4 EC001415
ETIM 5 EC001415

Attribute Value
General information
Product type designation KP32F PN
Control elements
With parameterizable keys Yes
Keyboard
● Membrane keyboard
— user-definable label membrane keys Yes
● Function keys
— Number of function keys 32
● Short-stroke keys
— Number of short-stroke keys 32
Expansions for operator control of the process
● DP direct LEDs (LEDs as S7 output I/O) 8; Adjustable brightness
● Number of color modes for LED 5; red, green, blue, yellow, white
● Direct keys (keys as S7 input I/O) 32
Installation type/mounting
Mounting type Mounting clip
Mounting position vertical
Rack mounting No
Front mounting Yes
Rail mounting No
Wall mounting/direct mounting No
Mounting in portrait format possible Yes
Mounting in landscape format possible Yes
maximum permissible angle of inclination without external ventilation 30°; To the front/rear
Number of slots for command devices and signaling units 0
Supply voltage
Type of supply voltage DC
Rated value (DC) 24 V; 24 V looped through at connector, no interruption on pulling
permissible range, lower limit (DC) 20.4 V
permissible range, upper limit (DC) 28.8 V
Input current
Current consumption (rated value) 1 A
Digital inputs
Number of digital inputs 32; Total inputs and outputs max. 32 and 2x SIL 2 or 4x SIL 3
Input voltage
● Rated value (DC) 24 V
Digital outputs
Number of digital outputs 16; Max. 32 inputs and outputs (total)
Short-circuit protection Yes
Switching capacity of the outputs
● with resistive load, max. 100 mA
Output voltage
● Rated value (DC) 24 V; Non-isolated
Total current of the outputs
● Current per channel, max. 100 mA
● Current per group, max. 800 mA
Interfaces
Number of industrial Ethernet interfaces 2; For the construction of lines and rings without external switch
Number of PROFINET interfaces 2; Incl. switch
Industrial Ethernet
● Industrial Ethernet status LED 2; Per port
● Number of ports of the integrated switch 2; Per port
Protocols
PROFINET Yes; incl. shared device, 3rd party PLC
Supports protocol for PROFINET IO Yes
PROFINET CBA Yes
IRT No
PROFIsafe Yes; 2x SIL 3 (two-channel) or 4x SIL 2 (single-channel) emergency stop sensors
PROFIBUS No
EtherNet/IP No
MPI No
AS-Interface No
EIB/KNX No
Protocols (Ethernet)
● TCP/IP No
Redundancy mode
Media redundancy
— MRP Yes
Further protocols
● AS-Interface Safety at Work No
● CAN No
● Data-Highway No
● DeviceNet No
● DeviceNet Safety No
● Foundation Fieldbus No
● INTERBUS No
● INTERBUS-Safety No
● Local Operating Network No
● MODBUS No
● SafetyBUS p No
● SERCOS No
● SUCOnet No
● other bus systems No
Test commissioning functions
Illuminant test Yes; During switch on
Key and signal lamp test Yes; automatically when switching on
EMC
Emission of radio interference acc. to EN 55 011
● Limit class A, for use in industrial areas Yes; Group 1, measured at a distance of 10 m
● Limit class B, for use in residential areas No
Degree and class of protection
IP (at the front) IP65
IP (rear) IP20
NEMA (front)
● Enclosure Type 4 at the front No
● Enclosure Type 4x at the front Yes; Incl. NEMA12
Standards, approvals, certificates
CE mark Yes
cULus Yes
RCM (formerly C-TICK) Yes
KC approval Yes
EAC (formerly Gost-R) Yes
CCC No; not necessary
Suitable for safety functions Yes
Ecological footprint
● environmental product declaration Yes
Global warming potential
— global warming potential, (total) [CO2 eq] 113 kg
— global warming potential, (during production) [CO2 eq] 38.5 kg
— global warming potential, (during operation) [CO2 eq] 82.3 kg
— global warming potential, (after end of life cycle) [CO2 eq] -8.27 kg
Use in hazardous areas
● ATEX Zone 2 No
● ATEX Zone 22 No
● cULus Class I Zone 1 No
● cULus Class I Zone 2, Division 2 No
● FM Class I Division 2 No
Marine approval
● Germanischer Lloyd (GL) No
● American Bureau of Shipping (ABS) No
● Bureau Veritas (BV) No
● Det Norske Veritas (DNV) No
● Lloyds Register of Shipping (LRS) No
● Nippon Kaiji Kyokai (Class NK) No
● Polski Rejestr Statkow (PRS) No
Ambient conditions
Ambient temperature during operation
● min. 0 °C
● max. 55 °C
Operation (vertical installation)
— For vertical installation, min. 0 °C
— For vertical installation, max. 55 °C
Operation (max. tilt angle)
— At maximum tilt angle, min. 0 °C
— At maximum tilt angle, max. 45 °C
Operation (vertical installation, portrait format)
— For vertical installation, min. 0 °C
— For vertical installation, max. 55 °C
Operation (max. tilt angle, portrait format)
— At maximum tilt angle, min. 0 °C
— At maximum tilt angle, max. 45 °C
Ambient temperature during storage/transportation
● min. -20 °C
● max. 60 °C
Relative humidity
● Operation, max. 95 %; no condensation
Configuration
Configuration software
● STEP 7 Basic (TIA Portal) Yes
● STEP 7 Professional (TIA Portal) Yes
Functionality under WinCC (TIA Portal)
Process coupling
● S7-1200 Yes; with ET 200pro CPU and ET 200S CPU
● S7-1500 Yes
● S7-200 No
● S7-300/400 Yes; with F-CPU: STEP 7 V11 SP1 or higher and Safety V11 (or higher), without F-CPU STEP 7 or SIMATIC STEP 7 Basic V11 (or higher)
● LOGO! No
● WinAC Yes
● SINUMERIK No
● SIMOTION No
● Allen Bradley (EtherNet/IP) No
● Allen Bradley (DF1) No
● Mitsubishi (MC TCP/IP) No
● Mitsubishi (FX) No
● OMRON (FINS TCP) No
● OMRON (Host Link) No
● Modicon (Modbus TCP/IP) No
● Modicon (Modbus RTU) No
Mechanics/material
Enclosure material (front)
● Plastic No
● Aluminum Yes
● Stainless steel No
Service life
● Short-stroke keys (in switching cycles) 1 500 000
● LEDs (ON period) 100 %
Dimensions
Width of the housing front 295 mm
Height of housing front 155 mm
Mounting cutout, width 277 mm; Max. thickness of mounting plate 2 - 6 mm
Mounting cutout, height 137 mm
mounting depth 37 mm; Incl. angled SIMATIC Ethernet connector
Weights
Weight (without packaging) 1 220 g

Important documents

Repair accompanying note

Download the repair accompanying note as a PDF, or use the digital repair registration and send your defective modules to the EICHLER Service Centre for repair.

Laughing Eichler technician points to green PDF with special sale of automation technology

Your shopping basket

Loading shopping basket