SIEMENS 3RW4436-6BC44

  • EICHLER-art.no.: K0146299
  • EAN: 4011209625747
  • UPC: 754554924007

Product description

SIRIUS SOFT STARTER VALUES AT 400 V, 40 °C STANDARD: 162 A, 90 KW INSIDE-DELTA: 281 A, 160 KW 200-460 V AC, 230 V AC SCREW TERMINALS !!! PHASED-OUT PRODUCT !!! SUCCESSOR IS SIRIUS 3RW5, PREFERRED SUCCESSOR TYPE IS >>3RW5536-6HA14<<

Services for SIEMENS 3RW4436-6BC44

Repair

7-10 days

from 2.398,50 €

to 4.317,30 €

Replacement

Used

3-5 days

2 Pcs.

5.519,00 €

5.519,00 € *

Please enter an offer recipient here.


New

Delivery information
Export identifier AL: N ECCN: N
Net weight 6.25
Quantity 1 Stück
Packaging quantity 1
Additional product information
Product status EOP: 2022-10-01
EAN 4011209625747
UPC 754554924007
Static lot number 85371098
List indicator CC-IC10
Product group 3728
Country of origin CZ
Compliance with the substance restrictions according to RoHS directive Since: 20090528
Product classifications Version Classification
eClass 4 27-02-11-01
eClass 5.1 27-02-41-01
eClass 6.0 27-37-09-07
ETIM 3 /
ETIM 4 EC000640
ETIM 5 EC000640

Attribute Value
General technical data
product brand name SIRIUS
product designation Soft starter
product feature
● integrated bypass contact system Yes
● thyristors Yes
product function
● intrinsic device protection Yes
● motor overload protection Yes
● evaluation of thermistor motor protection Yes
● external reset Yes
● adjustable current limitation Yes
● inside-delta circuit Yes
product component motor brake output Yes
insulation voltage rated value 690 V
degree of pollution 3, acc. to IEC 60947-4-2
reference code according to EN 61346-2 Q
reference code according to DIN 40719 extended according to IEC 204-2 according to IEC 750 G
Power Electronics
operational current
● at 40 °C rated value 162 A
● at 50 °C rated value 145 A
● at 60 °C rated value 125 A
operational current for 3-phase motors at inside-delta circuit
● at 40 °C rated value 281 A
● at 50 °C rated value 251 A
● at 60 °C rated value 217 A
yielded mechanical performance for 3-phase motors
● at 230 V
— at standard circuit at 40 °C rated value 45 kW
— at inside-delta circuit at 40 °C rated value 90 kW
● at 400 V
— at standard circuit at 40 °C rated value 90 kW
— at inside-delta circuit at 40 °C rated value 160 kW
yielded mechanical performance [hp] for 3-phase AC motor at 200/208 V at standard circuit at 50 °C rated value 40 hp
operating frequency rated value 50 ... 60 Hz
relative negative tolerance of the operating frequency -10 %
relative positive tolerance of the operating frequency 10 %
operating voltage at standard circuit rated value 200 ... 460 V
relative negative tolerance of the operating voltage at standard circuit -15 %
relative positive tolerance of the operating voltage at standard circuit 10 %
operating voltage at inside-delta circuit rated value 200 ... 460 V
relative negative tolerance of the operating voltage at inside-delta circuit -15 %
relative positive tolerance of the operating voltage at inside-delta circuit 10 %
minimum load [%] 8 %
adjustable motor current for motor overload protection minimum rated value 32 A
continuous operating current [% of Ie] at 40 °C 115 %
power loss [W] at operational current at 40 °C during operation typical 95 W
Control circuit/ Control
type of voltage of the control supply voltage AC
control supply voltage frequency 1 rated value 50 Hz
control supply voltage frequency 2 rated value 60 Hz
relative negative tolerance of the control supply voltage frequency -10 %
relative positive tolerance of the control supply voltage frequency 10 %
control supply voltage 1 at AC
● at 50 Hz rated value 230 V
● at 60 Hz rated value 230 V
relative negative tolerance of the control supply voltage at AC at 50 Hz -15 %
relative positive tolerance of the control supply voltage at AC at 50 Hz 10 %
relative negative tolerance of the control supply voltage at AC at 60 Hz -15 %
relative positive tolerance of the control supply voltage at AC at 60 Hz 10 %
display version for fault signal Display
Mechanical data
width 170 mm
height 200 mm
depth 270 mm
fastening method screw fixing
mounting position with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
required spacing with side-by-side mounting
● upwards 100 mm
● at the side 5 mm
● downwards 75 mm
wire length maximum 500 m
number of poles for main current circuit 3
Connections/ Terminals
type of electrical connection
● for main current circuit busbar connection
● for auxiliary and control circuit screw-type terminals
number of NC contacts for auxiliary contacts 0
number of NO contacts for auxiliary contacts 3
number of CO contacts for auxiliary contacts 1
type of connectable conductor cross-sections for main contacts for box terminal using the front clamping point
● finely stranded with core end processing 16 ... 70 mm²
● finely stranded without core end processing 16 ... 70 mm²
● stranded 16 ... 70 mm²
type of connectable conductor cross-sections for main contacts for box terminal using the back clamping point
● finely stranded with core end processing 16 ... 70 mm²
● finely stranded without core end processing 16 ... 70 mm²
● stranded 16 ... 70 mm²
type of connectable conductor cross-sections for main contacts for box terminal using both clamping points
● finely stranded with core end processing max. 1x 50 mm², 1x 70 mm²
● finely stranded without core end processing max. 1x 50 mm², 1x 70 mm²
● stranded max. 2x 70 mm²
type of connectable conductor cross-sections for AWG cables for main contacts for box terminal
● using the back clamping point 6 ... 2/0
● using the front clamping point 6 ... 2/0
● using both clamping points max. 2x 1/0
type of connectable conductor cross-sections for DIN cable lug for main contacts
● finely stranded 16 ... 95 mm²
● stranded 25 ... 120 mm²
type of connectable conductor cross-sections for auxiliary contacts
● solid 2x (0.5 ... 2.5 mm²)
● finely stranded with core end processing 2x (0.5 ... 1.5 mm²)
type of connectable conductor cross-sections for AWG cables
● for main contacts 4 ... 250 kcmil
● for auxiliary contacts 2x (20 ... 14)
● for auxiliary contacts finely stranded with core end processing 2x (20 ... 16)
Ambient conditions
installation altitude at height above sea level 5 000 m
environmental category
● during transport according to IEC 60721 2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
● during storage according to IEC 60721 1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4
● during operation according to IEC 60721 3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
ambient temperature
● during operation 60 °C
● during storage -25 ... +80 °C
derating temperature 40 °C
protection class IP on the front according to IEC 60529 IP00; IP20 with box terminal/cover
touch protection on the front according to IEC 60529 finger-safe, for vertical contact from the front with box terminal/cover
UL/CSA ratings
yielded mechanical performance [hp] for 3-phase AC motor
● at 200/208 V
— at inside-delta circuit at 50 °C rated value 75 hp
● at 220/230 V
— at standard circuit at 50 °C rated value 50 hp
— at inside-delta circuit at 50 °C rated value 100 hp
● at 460/480 V
— at standard circuit at 50 °C rated value 100 hp
— at inside-delta circuit at 50 °C rated value 200 hp
contact rating of auxiliary contacts according to UL B300 / R300

Important documents

Repair accompanying note

Download the repair accompanying note as a PDF, or use the digital repair registration and send your defective modules to the EICHLER Service Centre for repair.

Laughing Eichler technician points to green PDF with special sale of automation technology