| General technical data |
|
| product brand name |
SIRIUS |
| product designation |
Soft starter |
| product feature |
|
| ● integrated bypass contact system |
Yes |
| ● thyristors |
Yes |
| product function |
|
| ● intrinsic device protection |
Yes |
| ● motor overload protection |
Yes |
| ● evaluation of thermistor motor protection |
Yes |
| ● external reset |
Yes |
| ● adjustable current limitation |
Yes |
| ● inside-delta circuit |
Yes |
| product component motor brake output |
Yes |
| insulation voltage rated value |
690 V |
| degree of pollution |
3, acc. to IEC 60947-4-2 |
| reference code according to EN 61346-2 |
Q |
| reference code according to DIN 40719 extended according to IEC 204-2 according to IEC 750 |
G |
| Power Electronics |
|
| operational current |
|
| ● at 40 °C rated value |
162 A |
| ● at 50 °C rated value |
145 A |
| ● at 60 °C rated value |
125 A |
| operational current for 3-phase motors at inside-delta circuit |
|
| ● at 40 °C rated value |
281 A |
| ● at 50 °C rated value |
251 A |
| ● at 60 °C rated value |
217 A |
| yielded mechanical performance for 3-phase motors |
|
| ● at 230 V |
|
| — at standard circuit at 40 °C rated value |
45 kW |
| — at inside-delta circuit at 40 °C rated value |
90 kW |
| ● at 400 V |
|
| — at standard circuit at 40 °C rated value |
90 kW |
| — at inside-delta circuit at 40 °C rated value |
160 kW |
| yielded mechanical performance [hp] for 3-phase AC motor at 200/208 V at standard circuit at 50 °C rated value |
40 hp |
| operating frequency rated value |
50 ... 60 Hz |
| relative negative tolerance of the operating frequency |
-10 % |
| relative positive tolerance of the operating frequency |
10 % |
| operating voltage at standard circuit rated value |
200 ... 460 V |
| relative negative tolerance of the operating voltage at standard circuit |
-15 % |
| relative positive tolerance of the operating voltage at standard circuit |
10 % |
| operating voltage at inside-delta circuit rated value |
200 ... 460 V |
| relative negative tolerance of the operating voltage at inside-delta circuit |
-15 % |
| relative positive tolerance of the operating voltage at inside-delta circuit |
10 % |
| minimum load [%] |
8 % |
| adjustable motor current for motor overload protection minimum rated value |
32 A |
| continuous operating current [% of Ie] at 40 °C |
115 % |
| power loss [W] at operational current at 40 °C during operation typical |
95 W |
| Control circuit/ Control |
|
| type of voltage of the control supply voltage |
AC |
| control supply voltage frequency 1 rated value |
50 Hz |
| control supply voltage frequency 2 rated value |
60 Hz |
| relative negative tolerance of the control supply voltage frequency |
-10 % |
| relative positive tolerance of the control supply voltage frequency |
10 % |
| control supply voltage 1 at AC |
|
| ● at 50 Hz rated value |
230 V |
| ● at 60 Hz rated value |
230 V |
| relative negative tolerance of the control supply voltage at AC at 50 Hz |
-15 % |
| relative positive tolerance of the control supply voltage at AC at 50 Hz |
10 % |
| relative negative tolerance of the control supply voltage at AC at 60 Hz |
-15 % |
| relative positive tolerance of the control supply voltage at AC at 60 Hz |
10 % |
| display version for fault signal |
Display |
| Mechanical data |
|
| width |
170 mm |
| height |
200 mm |
| depth |
270 mm |
| fastening method |
screw fixing |
| mounting position |
with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back |
| required spacing with side-by-side mounting |
|
| ● upwards |
100 mm |
| ● at the side |
5 mm |
| ● downwards |
75 mm |
| wire length maximum |
500 m |
| number of poles for main current circuit |
3 |
| Connections/ Terminals |
|
| type of electrical connection |
|
| ● for main current circuit |
busbar connection |
| ● for auxiliary and control circuit |
screw-type terminals |
| number of NC contacts for auxiliary contacts |
0 |
| number of NO contacts for auxiliary contacts |
3 |
| number of CO contacts for auxiliary contacts |
1 |
| type of connectable conductor cross-sections for main contacts for box terminal using the front clamping point |
|
| ● finely stranded with core end processing |
16 ... 70 mm² |
| ● finely stranded without core end processing |
16 ... 70 mm² |
| ● stranded |
16 ... 70 mm² |
| type of connectable conductor cross-sections for main contacts for box terminal using the back clamping point |
|
| ● finely stranded with core end processing |
16 ... 70 mm² |
| ● finely stranded without core end processing |
16 ... 70 mm² |
| ● stranded |
16 ... 70 mm² |
| type of connectable conductor cross-sections for main contacts for box terminal using both clamping points |
|
| ● finely stranded with core end processing |
max. 1x 50 mm², 1x 70 mm² |
| ● finely stranded without core end processing |
max. 1x 50 mm², 1x 70 mm² |
| ● stranded |
max. 2x 70 mm² |
| type of connectable conductor cross-sections for AWG cables for main contacts for box terminal |
|
| ● using the back clamping point |
6 ... 2/0 |
| ● using the front clamping point |
6 ... 2/0 |
| ● using both clamping points |
max. 2x 1/0 |
| type of connectable conductor cross-sections for DIN cable lug for main contacts |
|
| ● finely stranded |
16 ... 95 mm² |
| ● stranded |
25 ... 120 mm² |
| type of connectable conductor cross-sections for auxiliary contacts |
|
| ● solid |
2x (0.5 ... 2.5 mm²) |
| ● finely stranded with core end processing |
2x (0.5 ... 1.5 mm²) |
| type of connectable conductor cross-sections for AWG cables |
|
| ● for main contacts |
4 ... 250 kcmil |
| ● for auxiliary contacts |
2x (20 ... 14) |
| ● for auxiliary contacts finely stranded with core end processing |
2x (20 ... 16) |
| Ambient conditions |
|
| installation altitude at height above sea level |
5 000 m |
| environmental category |
|
| ● during transport according to IEC 60721 |
2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m) |
| ● during storage according to IEC 60721 |
1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4 |
| ● during operation according to IEC 60721 |
3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6 |
| ambient temperature |
|
| ● during operation |
60 °C |
| ● during storage |
-25 ... +80 °C |
| derating temperature |
40 °C |
| protection class IP on the front according to IEC 60529 |
IP00; IP20 with box terminal/cover |
| touch protection on the front according to IEC 60529 |
finger-safe, for vertical contact from the front with box terminal/cover |
| UL/CSA ratings |
|
| yielded mechanical performance [hp] for 3-phase AC motor |
|
| ● at 200/208 V |
|
| — at inside-delta circuit at 50 °C rated value |
75 hp |
| ● at 220/230 V |
|
| — at standard circuit at 50 °C rated value |
50 hp |
| — at inside-delta circuit at 50 °C rated value |
100 hp |
| ● at 460/480 V |
|
| — at standard circuit at 50 °C rated value |
100 hp |
| — at inside-delta circuit at 50 °C rated value |
200 hp |
| contact rating of auxiliary contacts according to UL |
B300 / R300 |