SIEMENS 3RK1315-6KS41-0AA3

  • EICHLER-art.no.: K0241733
  • EAN: 4011209822955
  • UPC: 662643543889

Product description

SIRIUS MOTOR STARTER M200D AS-I COMMUNICATION: AS-INTERFACE DOL STARTER BASIC MECHANICAL SWITCHING AC-3, 0.75KW / 400 V 0.15 A...2.00 A ELECTRONIC OVERLOAD PROTECTION THERMISTOR: THERMOCLICK / PTC WITH BRAKE CONTACT 400 V/230 V AC 2DI AS-I + 2DI / 1DO ON

Services for SIEMENS 3RK1315-6KS41-0AA3

Repair

7-10 days

from 625,50 €

to 1.042,50 €

Replacement

Used

New

Delivery information
Export identifier AL: N ECCN: EAR99
Net weight 3.66
Quantity 1 Stück
Packaging quantity 1
Additional product information
Product status
EAN 4011209822955
UPC 662643543889
Static lot number 85371098
List indicator CC-IC10
Product group 3722
Country of origin DE
Compliance with the substance restrictions according to RoHS directive Since: 20060701
Product classifications Version Classification
eClass 4 27-37-04-01
eClass 5.1 27-37-09-05
eClass 6.0 27-37-09-05
ETIM 3 /
ETIM 4 EC001037
ETIM 5 EC001037

Attribute Value
product brand name SIRIUS
product designation Motor starters
design of the product direct starter
product type designation M200D
product function
● on-site operation No
● control circuit interface to parallel wiring No
insulation voltage rated value 500 V
degree of pollution 3
surge voltage resistance rated value 6 000 V
maximum permissible voltage for protective separation
● between main and auxiliary circuit 400 V
● between control and auxiliary circuit 24 V
shock resistance 12 g / 11 ms
vibration resistance 7 mm / 2 g
mechanical service life (operating cycles) of the main contacts typical 10 000 000
type of coordination 2
Substance Prohibitance (day/month/year) 38724
SVHC substance name Lead CAS-No. 7439-92-1
Lead monoxide (lead oxide) CAS-No. 1317-36-8
2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-10-5
Melamine CAS-No. 108-78-1
6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol CAS-No. 119-47-1
Net Weight 2.752 kg
product function
● direct start Yes
● reverse starting No
product component motor brake output Yes
product feature
● brake control with 230 V AC Yes
● brake control with 400 V AC Yes
● brake control with 24 V DC No
● brake control with 180 V DC No
● brake control with 500 V DC No
product extension braking module for brake control No
product function short circuit protection Yes
design of short-circuit protection circuit-breakers
maximum short-circuit current breaking capacity (Icu)
● at 400 V rated value 50 000 A
● at 500 V rated value 50 000 A
EMC emitted interference according to IEC 60947-1 CISPR11, ambience A (industrial sector)
EMC immunity according to IEC 60947-1 corresponds to degree of severity 3, ambience A (industrial sector)
conducted interference
● due to burst according to IEC 61000-4-4 2 kV network connection / 1 kV control connection
● due to conductor-earth surge according to IEC 61000-4-5 2 kV
● due to conductor-conductor surge according to IEC 61000-4-5 1 kV
Safety related data
proportion of dangerous failures
● with low demand rate according to SN 31920 50 %
● with high demand rate according to SN 31920 75 %
B10 value with high demand rate according to SN 31920 1 000 000
failure rate [FIT] with low demand rate according to SN 31920 100 FIT
IEC 61508
T1 value for proof test interval or service life according to IEC 61508 20 a
Electrical Safety
touch protection against electrical shock finger-safe
Main circuit
number of poles for main current circuit 3
design of the switching contact electromechanical
adjustable current response value current of the current-dependent overload release 0.15 ... 2 A
type of the motor protection full motor protection
operating voltage rated value 200 ... 440 V
operational current
● at AC at 400 V rated value 2 A
● at AC-3 at 400 V rated value 2 A
operating power
● at AC-3
— at 400 V rated value 0.75 kW
— at 500 V rated value 750 W
● at AC-3e
— at 400 V rated value 1 kW
— at 500 V rated value 0.75 kW
product function
● digital inputs parameterizable No
● digital outputs parameterizable No
number of digital inputs 4
number of sockets
● for digital output signals 1
● for digital input signals 4
number of digital outputs 1
Supply voltage
type of voltage of the supply voltage DC
supply voltage 1 at DC 24 V
supply voltage 1 at DC rated value 30 V
● minimum permissible 26.5 V
● maximum permissible 31.6 V
Control circuit/ Control
type of voltage of the control supply voltage DC
control supply voltage at DC rated value 20.4 ... 28.8 V
control supply voltage 1 at DC rated value 24 V
control supply voltage 1 at DC rated value 20.4 ... 28.8 V
control supply voltage 1 at DC 20.4 ... 28.8 V
control current at DC
● in standby mode of operation 100 mA
● during operation 600 mA
power loss [W] in auxiliary and control circuit
● in switching state OFF with bypass circuit 2.0736 W
● in switching state ON with bypass circuit 4.1184 W
Response times
ON-delay time 85 ms
OFF-delay time 65 ms
mounting position vertical, horizontal, flat
mounting position recommended horizontal
fastening method screw fixing
height 215 mm
width 294 mm
depth 159 mm
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
● during operation -25 ... +55 °C
● during storage -40 ... +70 °C
● during transport -40 ... +70 °C
relative humidity during operation 10 ... 95 %
protocol is supported
● PROFIBUS DP protocol No
● PROFINET protocol No
design of the interface
● AS-Interface protocol Yes
● PROFINET protocol No
● PROFIBUS DP protocol No
product function bus communication Yes
protocol is supported AS-Interface protocol Yes
product function control circuit interface with IO link No
type of electrical connection of the communication interface M12 plug
type of electrical connection
● for main current circuit plug according to ISO 23570, HAN Q4/2
● for auxiliary and control circuit connector
type of electrical connection
● 1 for digital input signals M12 socket
● 1 for digital output signals M12 socket
● 2 for digital input signals M12 socket
● 3 for digital input signals M12 socket
● 4 for digital input signals M12 socket
type of electrical connection
● at the manufacturer-specific device interface optical interface
● for device addressing M12 plug
● for supply voltage line-side M12 plug
full-load current (FLA) for 3-phase AC motor at 480 V rated value 1.6 A
yielded mechanical performance [hp]
● for 3-phase AC motor
— at 460/480 V rated value 0.7 hp
— at 575/600 V rated value 1 hp
operating voltage at AC at 60 Hz according to CSA and UL rated value 600 V

Important documents

Repair accompanying note

Download the repair accompanying note as a PDF, or use the digital repair registration and send your defective modules to the EICHLER Service Centre for repair.

Laughing Eichler technician points to green PDF with special sale of automation technology

Your shopping basket

Loading shopping basket