SIEMENS 6GK7343-1GX31-0XE0
- EICHLER-art.no.: K0340150
- EAN: 4019169227001
- UPC: 887621032623
Product description
SIMATIC NET CP 343-1 ADVANCED; FOR CONNECTING SIMATIC S7-300 CPU TO IND. ETHERNET; PROFINET IO CONTROLLER AND/OR IO-DEVICE; RT AND IRT MRP, PROFINET CBA; TCP/IP; ISO,UDP,S7-COM,S5-KOMP. COM., (SEND/RECEIVE) W. FETCH/WRITE WITH AND WITHOUT RFC 1006, MULTICAST DIAGNOSIS EXTENSION, SNMP, DHCP, FTP CLIENT/SERVER, E-MAIL, GIGABIT-SS1X RJ45 (10/100/1000) PROFINET-SS 2X RJ45(10/100MBIT) PROFINET CBA; SECURITY (FIREWALL/VPN); PROFIENERGY
Services for SIEMENS 6GK7343-1GX31-0XE0
Repair
from 1.691,16 €
to 2.487,00 €
Replacement
Used
2.873,00 €
2.729,35 €
New
SIEMENS |
6GK7343-1GX31-0XE0 –
additional product information
| Delivery information | |||
|---|---|---|---|
| Export identifier | AL: N ECCN: 5A002ENCA3 | ||
| Net weight | 0.507 | ||
| Quantity | 1 Stück | ||
| Packaging quantity | 1 | ||
| Additional product information | |||
|---|---|---|---|
| Product status | EOP: 2025-10-01 | ||
| EAN | 4019169227001 | ||
| UPC | 887621032623 | ||
| Static lot number | 85176200 | ||
| List indicator | IK | ||
| Product group | X0AI | ||
| Country of origin | DE | ||
| Compliance with the substance restrictions according to RoHS directive | Since: 20030101 | ||
| Product classifications | Version | Classification | |
|---|---|---|---|
| eClass | 4 | / | |
| eClass | 5.1 | 27-24-22-08 | |
| eClass | 6.0 | 27-24-22-08 | |
| ETIM | 3 | / | |
| ETIM | 4 | EC001423 | |
| ETIM | 5 | EC001423 | |
| Attribute | Value |
|---|---|
| product brand name | SIMATIC NET |
| transfer rate | |
| transfer rate | |
| ● at the 1st interface | 10 ... 1000 Mbit/s |
| ● at the 2nd interface | 10 ... 100 Mbit/s |
| interfaces | |
| number of interfaces / according to Industrial Ethernet | 3 |
| number of electrical connections | |
| ● at the 1st interface / according to Industrial Ethernet | 1 |
| ● at the 2nd interface / according to Industrial Ethernet | 2 |
| ● for power supply | 1 |
| type of electrical connection | |
| ● at the 1st interface / according to Industrial Ethernet | RJ45 port |
| ● at the 2nd interface / according to Industrial Ethernet | RJ45 port |
| type of electrical connection | |
| ● for power supply | 2-pole plugable terminal block |
| design of the removable storage | |
| ● C-PLUG | Yes |
| supply voltage, current consumption, power loss | |
| type of voltage / of the supply voltage | DC |
| supply voltage / 1 / from backplane bus | 5 V |
| supply voltage / external | 24 V |
| supply voltage / external / at DC / rated value | 24 V |
| relative positive tolerance / at DC / at 24 V | 20 % |
| relative negative tolerance / at DC / at 24 V | 15 % |
| consumed current | |
| ● from backplane bus / at DC / at 5 V / typical | 0.14 A |
| ● from external supply voltage / at DC / at 24 V / typical | 0.48 A |
| ● from external supply voltage / at DC / at 24 V / maximum | 0.62 A |
| power loss [W] | 14.7 W |
| ambient conditions | |
| ambient temperature | |
| ● for vertical installation / during operation | 0 ... 40 °C |
| ● for horizontally arranged busbars / during operation | 0 ... 60 °C |
| ● during storage | -40 ... +70 °C |
| ● during transport | -40 ... +70 °C |
| relative humidity | |
| ● at 25 °C / without condensation / during operation / maximum | 95 % |
| protection class IP | IP20 |
| design, dimensions and weights | |
| module format | Compact module |
| width | 80 mm |
| height | 125 mm |
| depth | 120 mm |
| net weight | 0.45 kg |
| fastening method | |
| ● S7-300 rail mounting | Yes |
| performance data / open communication | |
| number of possible connections / for open communication / by means of SEND/RECEIVE blocks / maximum | 16 |
| data volume | |
| ● as user data per ISO connection / for open communication / by means of SEND/RECEIVE blocks / maximum | 8 Kibyte |
| ● as user data per ISO on TCP connection / for open communication / by means of SEND/RECEIVE blocks / maximum | 8 Kibyte |
| ● as user data per TCP connection / for open communication / by means of SEND/RECEIVE blocks / maximum | 8 Kibyte |
| ● as user data per UDP connection / for open IE communication / by means of SEND/RECEIVE blocks / maximum | 2 Kibyte |
| number of Multicast stations | 16 |
| performance data / S7 communication | |
| number of possible connections / for S7 communication | |
| ● maximum | 16 |
| performance data / multi-protocol mode | |
| number of active connections / with multi-protocol mode | 48 |
| performance data / IT functions | |
| number of possible connections | |
| ● as client / by means of FTP / maximum | 10 |
| ● as server / by means of FTP / maximum | 2 |
| number of possible connections | |
| ● as server / by means of HTTP / maximum | 4 |
| ● as email client / maximum | 1 |
| data volume / as user data for email / maximum | 8 Kibyte |
| storage capacity / of the user memory | |
| ● as flash memory file system | 28 Mibyte |
| ● as RAM | 30 Mibyte |
| number of possible write cycles / of the flash memory cells | 100000 |
| performance data / PROFINET communication / as PN IO controller | |
| product function / PROFINET IO controller | Yes |
| number of PN IO devices / on PROFINET IO controller / operable / total | 128 |
| number of PN IO IRT devices / on PROFINET IO controller / operable | 128 |
| number of external PN IO lines / with PROFINET / per rack | 1 |
| data volume | |
| ● as user data for input variables / as PROFINET IO controller / maximum | 4 Kibyte |
| ● as user data for output variables / as PROFINET IO controller / maximum | 4 Kibyte |
| ● as user data for input variables per PN IO device / as PROFINET IO controller / maximum | 1433 byte |
| ● as user data for output variables per PN IO device / as PROFINET IO controller / maximum | 1433 byte |
| ● as user data for input variables per PN IO device / for each sub-module as PROFINET IO controller / maximum | 240 byte |
| ● as user data for output variables per PN IO device / for each sub-module as PROFINET IO controller / maximum | 240 byte |
| performance data / PROFINET communication / as PN IO device | |
| product function / PROFINET IO device | Yes |
| data volume | |
| ● as user data for input variables / as PROFINET IO device / maximum | 1024 byte |
| ● as user data for output variables / as PROFINET IO device / maximum | 1024 byte |
| ● as user data for input variables / for each sub-module as PROFINET IO device | 240 byte |
| ● as user data for output variables / for each sub-module as PROFINET IO device | 240 byte |
| ● as user data for the consistency area for each sub-module | 240 byte |
| number of submodules / per PROFINET IO-Device | 32 |
| performance data / PROFINET CBA | |
| number of remote connection partners / with PROFINET CBA | 64 |
| number of connections / with PROFINET CBA / total | 1000 |
| data volume | |
| ● as user data for digital inputs / with PROFINET CBA / maximum | 8 Kibyte |
| ● as user data for digital outputs / with PROFINET CBA / maximum | 8 Kibyte |
| ● as user data for arrays and data types / in the case of acyclic transmission / with PROFINET CBA / maximum | 8 Kibyte |
| ● as user data for arrays and data types / with PROFINET CBA / with cyclical transfer / maximum | 250 byte |
| ● as user data for arrays and data types / with PROFINET CBA / in the case of local interconnection / maximum | 2400 byte |
| performance data / PROFINET CBA / remote interconnection / with acyclic transfer | |
| update time / of the remote interconnections / in the case of acyclic transmission / with PROFINET CBA | 100 ms |
| number of remote connections to input variables / in the case of acyclic transmission / with PROFINET CBA / maximum | 128 |
| number of remote connections to output variables / in the case of acyclic transmission / with PROFINET CBA / maximum | 128 |
| data volume | |
| ● as user data for remote interconnections with input variables / in the case of acyclic transmission / with PROFINET CBA | 8 Kibyte |
| ● as user data for remote interconnections with output variables / in the case of acyclic transmission / with PROFINET CBA | 8 Kibyte |
| performance data / PROFINET CBA / remote interconnection / with cyclic transfer | |
| update time / of the remote interconnections / with cyclical transfer / with PROFINET CBA | 8 ms |
| number of remote connections to input variables / with PROFINET CBA / with cyclic transfer / maximum | 200 |
| number of remote connections to output variables / with cyclical transfer / with PROFINET CBA / maximum | 200 |
| data volume | |
| ● as user data for remote interconnections with input variables / with cyclical transfer / with PROFINET CBA / maximum | 2000 byte |
| ● as user data for remote interconnections with output variables / with cyclical transfer / with PROFINET CBA / maximum | 2000 byte |
| performance data / PROFINET CBA / HMI variables via PROFINET / acyclic | |
| number of connectable HMI stations / for HMI variables / in the case of acyclic transmission / with PROFINET CBA | 3 |
| update time / of the HMI variables / in the case of acyclic transmission / with PROFINET CBA | 500 ms |
| number of HMI variables / in the case of acyclic transmission / with PROFINET CBA / maximum | 200 |
| data volume / as user data for HMI variables / in the case of acyclic transmission / with PROFINET CBA / maximum | 8 Kibyte |
| performance data / PROFINET CBA / device-internal interconnections | |
| number of internal connections / with PROFINET CBA / maximum | 256 |
| data volume / of the internal connections / with PROFINET CBA / maximum | 2400 byte |
| performance data / PROFINET CBA / interconnections to constants | |
| number of connections with constants / with PROFINET CBA / maximum | 200 |
| data volume / as user data for interconnections with constants / with PROFINET CBA / maximum | 4096 byte |
| performance data / PROFINET CBA / PROFIBUS proxy functionality | |
| product function / with PROFINET CBA / PROFIBUS proxy functionality | No |
| performance data / telecontrol | |
| protocol / is supported | |
| ● TCP/IP | Yes |
| product functions / management, configuration, engineering | |
| product function / MIB support | Yes |
| protocol / is supported | |
| ● SNMP v1 | Yes |
| ● SNMP v3 | Yes |
| ● DCP | Yes |
| ● LLDP | Yes |
| configuration software | |
| ● required | STEP7 V5.5 SP2 HF1 or higher / STEP 7 Professional V12 (TIA Portal) or higher |
| ● for PROFINET CBA / required | SIMATIC iMap V3.0 SP4 and higher |
| identification & maintenance function | |
| ● I&M0 - device-specific information | Yes |
| ● I&M1 - higher level designation/location designation | Yes |
| product function / is supported / identification link | Yes; acc. to IEC 61406-1:2022 |
| product functions / diagnostics | |
| product function / web-based diagnostics | Yes |
| product functions / switch | |
| product feature / switch | Yes |
| product function | |
| ● switch-managed | No |
| ● with IRT / PROFINET IO switch | Yes |
| ● configuration with STEP 7 | Yes |
| product functions / redundancy | |
| product function | |
| ● ring redundancy | Yes |
| ● redundancy manager | Yes |
| protocol / is supported / Media Redundancy Protocol (MRP) | Yes |
| product functions / security | |
| firewall version | stateful inspection |
| product function / with VPN connection | IPSec |
| type of encryption algorithms / with VPN connection | AES-256, AES-192, AES-128, 3DES-168, DES-56 |
| type of authentication procedure / with VPN connection | Preshared key (PSK), X.509v3 certificates |
| type of hashing algorithms / with VPN connection | MD5, SHA-1 |
| number of possible connections / with VPN connection | 32 |
| product function | |
| ● password protection for Web applications | Yes |
| ● ACL - IP-based | Yes |
| ● ACL - IP-based for PLC/routing | Yes |
| ● switch-off of non-required services | Yes |
| ● blocking of communication via physical ports | Yes |
| ● log file for unauthorized access | No |
| product functions / time | |
| product function / SICLOCK support | Yes |
| product function / pass on time synchronization | Yes |
| protocol / is supported | |
| ● NTP | Yes |
| standards, specifications, approvals | |
| certificate of suitability / CE marking | Yes |
| certificate of suitability / UKCA marking | Yes |
| certificate of suitability / KC approval | Yes |
| certificate of suitability / Regulatory Compliance Mark (RCM) | Yes |
| certificate of suitability / RoHS conformity | Yes |
| certificate of suitability / EAC approval | Yes |
| standards, specifications, approvals / hazardous environments / header | |
| certificate of suitability / ATEX | Yes |
| certificate of suitability / IECEx | Yes |
| certificate of suitability / ULhazloc approval | Yes |
| certificate of suitability / CCC / for hazardous zone according to GB standard | Yes |
| certificate of suitability / FM registration | Yes |
| standards, specifications, approvals / marine classification / header | |
| Marine classification association / Polski Rejestr Statkow (PRS) | Yes |
| standards, specifications, approvals / Environmental Product Declaration | |
| Environmental Product Declaration | Yes |
| global warming potential [CO2 eq] | |
| ● total | 153.09999 kg |
| ● during manufacturing | 26.4 kg |
| ● during operation | 126.16 kg |
| ● after end of life | 0.54 kg |























