SIEMENS 6AV6644-0AA01-2AX0
-
SIEMENS | HMI | Touch Panels
- EICHLER-art.no.: K0199928
- EAN: 4025515075332
- UPC: 662643396966
Product description
SIMATIC MP 377 12" TOUCH MULTI PANEL, WINDOWS CE 5.0 12" COLOR TFT DISPLAY 12 MB CONFIGURATION MEMORY CONFIGURABLE FROM WINCC FLEXIBLE 2007
Services for SIEMENS 6AV6644-0AA01-2AX0
Repair
from 1.691,01 €
to 3.043,82 €
Replacement
3.620,70 €
Used
4.023,00 €
New
4.425,30 €
SIEMENS |
6AV6644-0AA01-2AX0 –
additional product information
| Delivery information | |||
|---|---|---|---|
| Export identifier | AL: N ECCN: 5D002ENCU | ||
| Net weight | 4.67 | ||
| Quantity | 1 Stück | ||
| Packaging quantity | 1 | ||
| Additional product information | |||
|---|---|---|---|
| Product status | |||
| EAN | 4025515075332 | ||
| UPC | 662643396966 | ||
| Static lot number | 85371098 | ||
| List indicator | ST9.80 | ||
| Product group | 2349 | ||
| Country of origin | DE | ||
| Compliance with the substance restrictions according to RoHS directive | Since: 20080331 | ||
| Product classifications | Version | Classification | |
|---|---|---|---|
| eClass | 4 | 27-36-01-02 | |
| eClass | 5.1 | 27-24-23-02 | |
| eClass | 6.0 | 27-24-23-02 | |
| ETIM | 3 | / | |
| ETIM | 4 | EC001412 | |
| ETIM | 5 | EC001412 | |
What is the 6AV6644-0AA01-2AX0 (MP 377 12" Touch)?
The 6AV6644-0AA01-2AX0 is a SIEMENS SIMATIC MP 377 12" Touch Multi Panel featuring Windows CE 5.0, a 12" colour TFT display and 12 MB of project/configuration memory. For a one-to-one replacement in existing systems, it is particularly important that the device can be engineered with WinCC flexible 2007 or later, allowing existing projects to continue running without the need for a platform change.
What is the 6AV6642-0DA01-1AX1 particularly suitable for?
It is particularly suitable as a one-to-one replacement for existing systems using the OP 177B PN/DP, where the existing touch operation and key/LED operating logic need to be retained.
Which connections are relevant for PLC communication?
The device supports MPI/PROFIBUS-DP and Ethernet 10/100, making it well suited to mixed S7 network environments.
Why is the spare-parts aspect important here?
Because the Siemens datasheet states that the device has been "blocked for delivery" as a new product since 01 January 2015, making spare-part supply routes increasingly important for maintaining system availability.
How quickly is service available and are there any verification options?
According to EICHLER, repairs are available within 1–3 days. An optional test report (€159) is also available to provide documented verification of the device's functionality.
Which identifiers help purchasing departments place the correct order?
For clear identification and procurement, the following references are useful: EICHLER part number K0219216, EAN 4025515076476, UPC 662643396867 and MPN 6AV6642-0DA01-1AX1.
| General information | |
|---|---|
| Product type designation | MP377 12" touch |
| Customer-specific configuration | No |
| Display | |
| Design of display | TFT |
| Screen diagonal | 12.1 in |
| Color display | Yes |
| Number of colors | 65 536 |
| Resolution (pixels) | |
| ● Horizontal image resolution | 800 pixel |
| ● Vertical image resolution | 600 pixel |
| Backlighting | |
| ● MTBF backlighting (at 25 °C) | 50 000 h |
| Control elements | |
| Control elements | Touch screen |
| Keyboard fonts | |
| ● Function keys | |
| — Number of function keys | 0 |
| — Number of function keys with LEDs | 0 |
| ● System keys | No |
| — Number of system keys | 0 |
| ● Numeric keyboard | Yes |
| ● alphanumeric keyboard | Yes |
| ● hexadecimal keyboard | Yes |
| Touch operation | |
| ● Design as touch screen | Yes; analog, resistive |
| Connection type | |
| ● Type of connection for mouse/keyboard/barcode reader | USB / USB / USB |
| Installation type/mounting | |
| maximum permissible angle of inclination without external ventilation | 35° |
| Supply voltage | |
| Type of supply voltage | DC |
| Input current | |
| Current consumption (rated value) | 1.5 A |
| Power | |
| Active power input, typ. | 36 W |
| Memory | |
| Type of memory | Flash / RAM |
| Memory available for user data | 12 288 kbyte |
| Time of day | |
| Clock | |
| ● Type | Hardware clock, battery backup, synchronizable |
| ● retentive | Yes |
| ● synchronizable | Yes |
| Interfaces | |
| Interfaces/bus type | 1x RS 422, 1x RS 485, 2x Ethernet (RJ45) |
| Number of industrial Ethernet interfaces | 2 |
| Number of RS 485 interfaces | 1 |
| Number of RS 422 interfaces | 1 |
| Number of USB interfaces | 2; Up to 1 GB respectively |
| CF card slot | 1x CF card slot |
| Multimedia card/SD card slot | 1x Multimedia Card slot, up to 128 MB |
| With software interfaces | No |
| Protocols | |
| Supports protocol for PROFINET IO | Yes |
| PROFIsafe | No |
| PROFIBUS | Yes |
| EtherNet/IP | Yes |
| MPI | Yes |
| Protocols (Ethernet) | |
| ● TCP/IP | Yes |
| Protocols (terminal link) | |
| ● Sm@rtServer | Yes |
| Further protocols | |
| ● MODBUS | Yes |
| EMC | |
| Emission of radio interference acc. to EN 55 011 | |
| ● Limit class A, for use in industrial areas | Yes |
| Degree and class of protection | |
| IP (at the front) | IP65 |
| IP (rear) | IP20 |
| NEMA (front) | NEMA 4, NEMA 12 (when installed) |
| Standards, approvals, certificates | |
| CE mark | Yes |
| UL approval | Yes |
| cULus | Yes |
| Suitable for safety functions | No |
| Use in hazardous areas | |
| ● ATEX Zone 2 | No; certificate no longer available as of 1 October 2020 |
| ● ATEX Zone 22 | No; certificate no longer available as of 1 October 2020 |
| ● FM Class I Division 2 | Yes |
| Ambient conditions | |
| Ambient temperature during operation | |
| ● min. | 0 °C |
| ● max. | 50 °C |
| Ambient temperature during storage/transportation | |
| ● min. | -20 °C |
| ● max. | 60 °C |
| Relative humidity | |
| ● Operation, max. | 90 % |
| Operating systems | |
| pre-installed operating system | Windows CE |
| Configuration | |
| Message indicator | Yes |
| Alarm system (incl. buffer and acknowledgment) | Yes |
| Process value display (output) | Yes |
| Process value default (input) possible | Yes |
| Recipe management | Yes |
| Configuration software | |
| ● Configuration tool | WinCC flexible Standard Version 2007 or higher (to be ordered separately) |
| ● STEP 7 Basic (TIA Portal) | No |
| ● STEP 7 Professional (TIA Portal) | No |
| ● WinCC flexible Compact | No |
| ● WinCC flexible Standard | Yes |
| ● WinCC flexible Advanced | Yes |
| ● WinCC Basic (TIA Portal) | No |
| ● WinCC Comfort (TIA Portal) | Yes |
| ● WinCC Advanced (TIA Portal) | Yes |
| ● WinCC Professional (TIA Portal) | Yes |
| Languages | |
| Online languages | |
| ● Number of online/runtime languages | 16 |
| Project languages | |
| ● Languages per project | 32 |
| Functionality under WinCC (TIA Portal) | |
| Libraries | Yes |
| Task planner | Yes |
| Help system | Yes |
| ● Number of characters per info text | 70 |
| Message system | |
| ● Number of alarm classes | 32 |
| ● Number of messages | 4 000 |
| ● Bit messages | Yes |
| — Number of bit messages | 4 000 |
| ● Analog messages | Yes |
| — Number of analog messages | 200 |
| ● Telegram message procedure Alarm S | Yes |
| ● System messages HMI | Yes |
| ● System messages PLC | Yes |
| ● System event, more (SIMATIC S7, SINUMERIK, SIMOTION, ... ) | Yes |
| ● Lines | 1 |
| ● Number of characters per message | 80 |
| ● Number of process values per message | 8 |
| ● Message indicator | Yes |
| ● First/last value | Yes |
| Recipe management | |
| ● Number of recipes | 500 |
| ● Data records per recipe | 1 000 |
| ● Entries per data record | 1 000 |
| ● Recipe memory | 128 KB integrated Flash, expandable |
| Variables | |
| ● Number of variables per device | 4 096; Configuration with WinCC flexible 2008 and higher |
| ● Number of variables per screen | 400 |
| ● Number of variables | 2 000 |
| ● Initial values | 2 048 |
| ● Type Date & Time | 2 048 |
| ● Limit values | Yes |
| ● Multiplexing | Yes |
| ● Structures | Yes |
| Images | |
| ● Number of configurable images | 500 |
| ● Permanent window/default | Yes |
| ● Start screen configurable | Yes |
| ● Image selection by PLC | Yes |
| ● Image number in the PLC | Yes |
| Image objects | |
| ● Text objects | 30 000 text elements |
| ● Number of I/O fields per image | 400 |
| ● Number of date/time fields | 400 |
| ● Return | Yes |
| ● Graphics object | Bit maps, icons, vector graphics |
| — Icons | 2 000 |
| Complex image objects | |
| ● Status/control | With SIMATIC S7 |
| ● dynamic objects | Diagrams, bar graphs, sliders, analog display, invisible buttons |
| — Number of objects per project | 2 000 |
| — Number of curve diagrams per image | 20 |
| ● Methods | Trend / profile |
| ● Bar graphs | |
| — Number of bars per chart | 20 |
| ● Sliders | |
| — Number of slides per image | 20 |
| ● Pointer instruments | |
| — Number of analog indicators per image | 20 |
| ● Limit value lines | Yes |
| ● Number of alphanumerical fields | 300 |
| — alphanumeric fields per image | 400 |
| ● Number of numerical fields | 2 048 |
| — numerical fields per image | 400 |
| ● Number of password fields | 2 048 |
| ● Number of visible switches per project | 400 |
| — visible switches per image | 400 |
| — hidden switches per image | 400 |
| ● Number of status switches per project | 400 |
| — Number of status switches per image | 400 |
| ● Number of selector switches per project | 400 |
| — Selector switches per image | 400 |
| ● Number of signal lamps per project | 400 |
| — Signal lamps per image | 400 |
| Attributes for dynamic objects | |
| ● Color change | Yes |
| ● X/Y movement | Yes |
| ● Hide | Yes |
| Lists | |
| ● Number of text lists per project | 500 |
| ● Number of text lists per image | 400 |
| ● Number of entries per text list | 256 |
| ● Number of graphics lists per project | 500 |
| ● Number of graphic lists per image | 400 |
| ● Number of entries per graphics list | 256 |
| Archiving | |
| ● Number of archives per device | 50 |
| ● Number of measuring points per project | 50 |
| ● Number of entries per archive | 50 000 |
| ● Message archive | Yes |
| ● Process value archive | Yes |
| ● Archiving methods | Sequential log, circular log, alarm log, process value archive |
| — Sequential archive | Yes |
| — Short-term archive | Yes |
| ● Memory location | CF card, SD/MMC card, Ethernet, USB memory stick |
| — CF card | Yes |
| — Ethernet | Yes |
| ● Data storage format | CSV file, readable, e.g. with MS Excel, MS Access |
| — CSV | Yes |
| ● external evaluation | readable, e.g. with MS Excel, MS Access, etc. |
| ● Size of archive | depending on free memory on ext. card/stick or on free hard disk space via network drive |
| ● Online evaluation | via trends |
| — using trend curves | Yes |
| Filters | |
| ● cyclic | Yes |
| ● Tolerance | Yes |
| ● Change | Yes |
| Security | |
| ● Number of user groups | 50 |
| ● Number of user rights | 32 |
| ● Password export/import | Yes |
| Data carrier support | |
| ● CF card | Yes |
| ● Hard disk | Yes |
| Logging through printer | |
| ● Recording/Printing | Alarms, report (shift report), color print, hardcopy |
| Transfer (upload/download) | |
| ● Transfer of configuration | MPI/PROFIBUS DP, serial, USB, Ethernet, by means of external storage medium, automatic transfer recognition |
| Process coupling | |
| ● Connection to controller | S5, S7-200, S7-300/400, TI 505, Win AC, PC (TCP/IP), SINUMERIK, SIMOTION, Allen Bradley (DF1), Allen Bradley (DF485), Mitsubishi (FX), OMRON (LINK/Multilink), Modicon (Modbus), further non-Siemens drivers, see chapter "System interfaces" |
| ● S7-1200 | Yes |
| ● S7-1500 | Yes |
| ● S7-200 | Yes |
| — PPI (point-to-point) | Yes |
| — PPI network | Yes |
| — MPI | Yes |
| — PROFIBUS DP | Yes |
| ● S7-300/400 | Yes |
| — MPI | Yes |
| — PROFIBUS DP | Yes |
| — PROFINET | Yes |
| ● S5 | Yes |
| — PROFIBUS DP | Yes |
| ● TI 505 | Yes |
| ● Allen Bradley (DF1) | Yes |
| ● Allen Bradley (DF485) | Yes |
| ● Mitsubishi (FX) | Yes |
| ● Mitsubishi (MP4) | Yes |
| ● Telemecanique (Uni-Telway) | Yes |
| ● OMRON (LINK/Multilink) | Yes |
| ● Modicon (Modbus) | Yes |
| ● GE-Fanuc (SNP) | Yes |
| Functions | |
| ● TAB sequence | Yes |
| ● Calculating functions | Yes |
| ● Animate | Yes |
| Service tools/configuration aids | |
| ● Clean screen | Yes |
| ● Touch calibration | Yes |
| ● Backup/Restore manually | Yes |
| ● Simulation | Yes |
| ● Device switchover | Yes |
| ● Delta transfer | Yes |
| Expandability/openness | |
| ● Open Platform Program | Yes |
| Peripherals/Options | |
| Peripherals | Printer, card reader, barcode reader |
| SIMATIC HMI MM memory card: Multi Media Card | Yes |
| SIMATIC HMI SD memory card: Secure Digital memory card | Yes |
| USB memory | Yes |
| Additional software components loadable | Yes |
| Dimensions | |
| Width of the housing front | 335 mm |
| Height of housing front | 275 mm |
| Mounting cutout, width | 310 mm |
| Mounting cutout, height | 248 mm |
| mounting depth | 72 mm |
| Weights | |
| Weight (without packaging) | 3.8 kg |
| Fault description | Possible solution |
|---|---|
| Panel does not start / Boot loop – what should be checked first? | First check the 24 V DC power supply for voltage drops and inspect all connectors. If the power supply is stable, an A/B test with a replacement panel is often the fastest way to distinguish between a hardware fault and a project or peripheral issue. (Service options are explicitly available as repair and exchange.) |
| Touchscreen responds inaccurately or not at all – what are the quickest checks? | Clean the front surface and check the touch calibration and operating interface. If the deviation remains reproducible, this often indicates touchscreen wear. In such cases, a tested replacement unit is frequently the quickest way to restore operation. |
| Display is dark or the image is barely visible – what is the most common cause? | In many cases, the backlight or its control circuitry is affected, which is a typical ageing issue in HMIs. In production-critical environments, an exchange unit is often the fastest way to confirm the diagnosis. |
| No communication with the PLC / network appears inactive – what should be checked first? | Start by checking the physical connection, including cables, ports and switches. Then verify the project configuration and device settings. With operator panels, communication hardware is often functioning correctly, but the project assignment or network parameters do not match. |
| Project transfer or restore fails – what is the quickest solution? | Try a different transfer path, where possible, and verify that the engineering software version is compatible. For this device, WinCC flexible 2007 is specified as the engineering platform, and matching the engineering version is often the key to resolving transfer-related issues. |
| When is repair or replacement more economical than further troubleshooting? | If operator functionality is production-critical or faults occur repeatedly, an exchange unit (1–3 days) or repair service (1–3 days) is usually more cost-effective than prolonged on-site diagnostics. An optional test report can also support documentation and audit requirements. |
What display and operating combination does the OP 177B feature?
STN display (256 colours) plus touch operation and keys (key operation).
Which interfaces are available in addition to the fieldbus communication interfaces?
RS485, RS422, USB, a printer interface and an MMC slot for media and service purposes.
Which software is required for engineering?
WinCC flexible 2005 (datasheet: WinCC flexible Compact 2005 or later).
What are the most common causes of communication problems in practice?
Usually incorrect bus parameters, addresses or termination settings on MPI/PROFIBUS-DP, or incorrect IP settings, ports or assignments on Ethernet 10/100. (The interfaces are specified in the device, so the parameters and physical connections should be checked first.)
Is there a lifecycle notice that affects replacement planning?
Yes: new units blocked for delivery (since 01 January 2015), while spare parts remain available.