SIEMENS 6AV6643-0CB01-1AX1

  • EICHLER-art.no.: K0199922
  • EAN: 4025515075363

Product description

SIMATIC MP 277 8" TOUCH MULTI PANEL WITH RETENTIVE MEMORY 7.5" TFT DISPLAY 6 MB CONFIGURATION MEMORY, CONFIGURABLE WITH WINCC FLEXIBLE 2005 STANDARD SP1

Services for SIEMENS 6AV6643-0CB01-1AX1

Repair

1-3 days

from 2.110,51 €

to 3.798,91 €

per pc. 159,00 €

Replacement

1-3 days

10+ Pcs.

2.651,40 €

per pc. 159,00 €

2.651,40 € *

Please enter an offer recipient here.


Used

1-3 days

10+ Pcs.

2.946,00 €

per pc. 159,00 €

2.946,00 € *

Please enter an offer recipient here.


New

Delivery information
Export identifier AL: N ECCN: 5D002ENCU
Net weight 2.205
Quantity 1 Stück
Packaging quantity 1
Additional product information
Product status EOP: 2023-10-01
EAN 4025515075363
UPC /
Static lot number 85371098
List indicator ST9.80
Product group 4357
Country of origin DE
Compliance with the substance restrictions according to RoHS directive Since: 20080331
Product classifications Version Classification
eClass 4 /
eClass 5.1 27-24-23-02
eClass 6.0 27-24-23-02
ETIM 3 /
ETIM 4 EC001412
ETIM 5 EC001412

What is the 6AV6643-0CB01-1AX1 and where is it used?

The SIEMENS 6AV6643-0CB01-1AX1 is a SIMATIC MP 277 8" Touch Multi Panel with a 7.5" TFT display, retentive memory and configuration via WinCC flexible 2005 Standard SP1 or later. The device is designed for traditional operator control and monitoring tasks in machines and industrial systems, particularly where existing visualisations, established communication structures and a defined installation location need to be retained. For maintenance engineers, the exact part number is important because it enables an installed unit to be accurately identified and assigned to the correct repair, replacement or procurement process. For purchasing and production teams, the panel is especially relevant in retrofit, spare-parts and downtime scenarios.

Overview of the key technical specifications and their practical significance

The MP 277 8" Touch provides a resolution of 640 × 480 pixels, 65,536 colours, an analogue resistive touchscreen, 6 MB of user memory, up to 128 MB of main memory, a 24 V DC power supply, 1 × Ethernet RJ45, 1 × RS422, 1 × RS485, 2 × USB ports and an MMC slot. The front is rated IP65, while the rear is rated IP20. The permissible operating temperature range is 0 to 50 °C, and the backlight is specified with an MTBF of 50,000 hours. In practice, this means the panel integrates well into existing automation environments, offers sufficient interfaces for service and data transfer, and remains technically suitable for many legacy installations despite its age.

Product status, lifecycle status and obsolescence

Obsolescence is a significant consideration for the 6AV6643-0CB01-1AX1. Siemens states in the current data sheet that the device has been blocked for delivery as a new product since 1 January 2015; spare-part supply remained possible afterwards, but no longer within the normal new-product framework. The EICHLER product page additionally lists an EOP (End of Product) date of 1 October 2023. For operators, this means that installed units should no longer be viewed as standard new purchases but rather as components that must be supported through repair, replacement, used-device sourcing and migration planning. Siemens identified 6AV6643-0CB01-1AX2 as the successor within the product line, while the TP900 Comfort is cited as the migration path to newer HMI generations. However, this should not be considered a direct 1:1 replacement without verification of both the project and installation requirements.

Available EICHLER services and when they are relevant

For this device, EICHLER offers repair, replacement, used units, new units on request and an optional test report. Repair, replacement and used-device supply are each listed with a lead time of 1–3 days. EICHLER states that repairs include technical cleaning, preventive maintenance, comprehensive functional testing and a minimum 24-month warranty. This is particularly valuable when the existing project, panel cut-out and machine approval status should remain unchanged. Replacement is the preferred option when downtime must be resolved immediately. Used devices can be beneficial when supply of original hardware has become limited. The optional test report supports approval procedures, documentation requirements and internal quality assurance following installation or return of the unit.

Attribute Value
Product type designation MP277 8" Touch
Customer-specific configuration Yes
Display
Design of display TFT
Screen diagonal 7.5 in
Color display Yes
Number of colors 65 536
Resolution (pixels)
● Horizontal image resolution 640 pixel
● Vertical image resolution 480 pixel
Backlighting
● MTBF backlighting (at 25 °C) 50 000 h
Control elements
Control elements Touch screen
Keyboard fonts
● Function keys
— Number of function keys 0
— Number of function keys with LEDs 0
● System keys No
— Number of system keys 0
● Numeric keyboard Yes
● alphanumeric keyboard Yes
● hexadecimal keyboard Yes
Touch operation
● Design as touch screen Yes; analog, resistive
Connection type
● Type of connection for mouse/keyboard/barcode reader USB / USB / USB
Installation type/mounting
Mounting position vertical
maximum permissible angle of inclination without external ventilation 35°
Supply voltage
Type of supply voltage DC
Processor
Processor type ARM
Memory
Type of memory Flash / RAM
Memory available for user data 6 Mbyte
Capacity of main memory, max. 128 Mbyte
Time of day
Clock
● Type Hardware clock, battery backup, synchronizable
● retentive Yes
● synchronizable Yes
Interfaces
Interfaces/bus type 1x RS 422, 1x RS 485, 1x Ethernet (RJ45)
Number of industrial Ethernet interfaces 1
Number of RS 485 interfaces 1
Number of RS 422 interfaces 1
Number of USB interfaces 2; Up to 1 GB respectively
Multimedia card/SD card slot 1x Multimedia Card slot, up to 128 MB
With software interfaces No
Protocols
Supports protocol for PROFINET IO Yes
PROFIsafe No
PROFIBUS Yes
EtherNet/IP No
Protocols (Ethernet)
● TCP/IP Yes
Further protocols
● MODBUS Yes
Degree and class of protection
IP (at the front) IP65
IP (rear) IP20
NEMA (front) NEMA 4x (when installed)
Standards, approvals, certificates
CE mark Yes
UL approval Yes
cULus Yes
Suitable for safety functions No
Use in hazardous areas
● ATEX Zone 2 No; certificate no longer available as of 1 October 2020
● ATEX Zone 22 No; certificate no longer available as of 1 October 2020
● FM Class I Division 2 Yes
Ambient conditions
Ambient temperature during operation
● min. 0 °C
● max. 50 °C
Ambient temperature during storage/transportation
● min. -20 °C
● max. 60 °C
Relative humidity
● Operation, max. 90 %
Operating systems
pre-installed operating system Windows CE
Configuration
Message indicator Yes
Alarm system (incl. buffer and acknowledgment) Yes
Process value display (output) Yes
Process value default (input) possible Yes
Recipe management Yes
Configuration software
● Configuration tool WinCC flexible Standard Version 2005 SP1 or higher (to be ordered separately)
● STEP 7 Basic (TIA Portal) No
● STEP 7 Professional (TIA Portal) No
● WinCC flexible Compact No
● WinCC flexible Standard Yes
● WinCC flexible Advanced Yes
● WinCC Basic (TIA Portal) No
● WinCC Comfort (TIA Portal) Yes
● WinCC Advanced (TIA Portal) Yes
● WinCC Professional (TIA Portal) Yes
Languages
Online languages
● Number of online/runtime languages 16
Project languages
● Languages per project 32
Functionality under WinCC (TIA Portal)
Libraries Yes
Task planner Yes
Help system Yes
● Number of characters per info text 70
Message system
● Number of alarm classes 32
● Number of messages 4 000
● Bit messages Yes
— Number of bit messages 4 000
● Analog messages Yes
— Number of analog messages 200
● System messages HMI Yes
● System messages PLC Yes
● System event, more (SIMATIC S7, SINUMERIK, SIMOTION, ... ) Yes
● Lines 1
● Number of characters per message 80
● Number of process values per message 8
● Acknowledgment groups Yes
● Message indicator Yes
● First/last value Yes
Recipe management
● Number of recipes 300
● Data records per recipe 500
● Entries per data record 1 000
● Recipe memory 64 KB integrated Flash, expandable
Variables
● Number of variables per device 2 048
● Number of variables per screen 200
● Number of variables 1 000
● Type Date & Time 2 048
● Limit values Yes
● Multiplexing Yes
● Structures Yes
Images
● Number of configurable images 500
● Permanent window/default Yes
● Start screen configurable Yes
● Image selection by PLC Yes
● Image number in the PLC Yes
Image objects
● Text objects 10 000 text elements
● Number of I/O fields per image 200
● Number of date/time fields 200
● Return Yes
● Graphics object Bit maps, icons, vector graphics
— Icons 1 000
Complex image objects
● Status/control With SIMATIC S7
● dynamic objects Diagrams, bar graphs, sliders, analog display, invisible buttons
— Number of objects per project 1 000
— Number of curve diagrams per image 10
● Methods Trend / profile
● Bar graphs
— Number of bars per chart 10
● Sliders
— Number of slides per image 10
● Pointer instruments
— Number of analog indicators per image 10
● Limit value lines Yes
● Number of alphanumerical fields 300
— alphanumeric fields per image 200
● Number of numerical fields 2 048
— numerical fields per image 200
● Number of password fields 2 048
● Number of visible switches per project 200
— visible switches per image 200
— hidden switches per image 200
● Number of status switches per project 200
— Number of status switches per image 200
● Number of selector switches per project 200
— Selector switches per image 200
● Number of decade switches per project 200
— Decade switches per image 200
● Number of signal lamps per project 200
— Signal lamps per image 200
Attributes for dynamic objects
● Color change Yes
● X/Y movement Yes
● Hide Yes
Lists
● Number of text lists per project 500
● Number of text lists per image 200
● Number of entries per text list 256
● Number of graphics lists per project 400
● Number of graphic lists per image 200
● Number of entries per graphics list 256
Archiving
● Number of archives per device 20
● Number of measuring points per project 20
● Number of entries per archive 10 000
● Message archive Yes
● Process value archive Yes
● Archiving methods
— Sequential archive Yes
— Short-term archive Yes
● Memory location SD and MultiMediaCard
— Ethernet Yes
● Data storage format
— CSV Yes
● Online evaluation
— using trend curves Yes
Filters
● cyclic Yes
● Tolerance Yes
● Change Yes
Security
● Number of user groups 50
● Number of user rights 32
● Password export/import Yes
Logging through printer
● Recording/Printing Alarms, report (shift report), color print, hardcopy
Transfer (upload/download)
● Transfer of configuration MPI/PROFIBUS DP, USB, Ethernet, automatic transfer recognition
Process coupling
● Connection to controller S5, S7-200, S7-300/400, TI 505, SINUMERIK, SIMOTION, Allen Bradley (DF1), Allen Bradley (DF485), Mitsubishi (FX), OMRON (LINK/Multilink), Modicon (Modbus) see chapter "System interfaces"
● S7-1200 Yes
● S7-1500 Yes
● S7-200 Yes
— PPI (point-to-point) Yes
— PPI network Yes
— MPI Yes
— PROFIBUS DP Yes
— Ethernet Yes
● S7-300/400 Yes
— MPI Yes
— PROFIBUS DP Yes
— PROFINET Yes
● S5 Yes
— PROFIBUS DP Yes
● TI 505 Yes
● Allen Bradley (DF1) Yes
● Allen Bradley (DF485) Yes
● Mitsubishi (FX) Yes
● Mitsubishi (MP4) Yes
● Telemecanique (Uni-Telway) Yes
● OMRON (LINK/Multilink) Yes
● Modicon (Modbus) Yes
● GE-Fanuc (SNP) Yes
Functions
● TAB sequence Yes
● Calculating functions Yes
● Animate Yes
Service tools/configuration aids
● Clean screen Yes
● Touch calibration Yes
● Backup/Restore manually Yes
● Simulation Yes
● Device switchover Yes
● Delta transfer Yes
Expandability/openness
● Open Platform Program Yes
Peripherals/Options
Peripherals Printer, barcode reader
SIMATIC HMI MM memory card: Multi Media Card Yes
SIMATIC HMI SD memory card: Secure Digital memory card Yes
USB memory Yes
Additional software components loadable Yes
Dimensions
Width of the housing front 250 mm
Height of housing front 190 mm
Mounting cutout, width 226 mm
Mounting cutout, height 166 mm
mounting depth 61 mm
Weights
Weight (without packaging) 1.61 kg

Fault description Possible solution
Why does the touchscreen respond inaccurately or register touches in the wrong position? On the MP 277, parallax effects can occur depending on the installation position and viewing angle. Siemens recommends performing a new calibration via Control Panel > OP Properties > Touch > Recalibrate. All calibration points must be confirmed correctly and the calibration must be saved within the specified time window. If the touchscreen is barely usable, an external USB mouse can be connected to access the Control Panel and perform calibration or further diagnostics.
Why can't a project be transferred to the MP 277? First check the Transfer Settings and ensure that at least one data channel is enabled on the panel. Siemens explicitly states that transfer is not possible otherwise. Then verify that the interface settings, bus parameters or IP configuration match between the PG/PC and the panel. If the project has been upgraded to a newer version of WinCC flexible, it is often necessary to load the appropriate OS image to the panel using ProSave before the project transfer can be completed successfully.
Why does the MP 277 remain in the bootloader after a failed OS update? An interrupted operating system update or a power failure during the update process can prevent the panel from starting normally. In this case, the operating system should be reloaded using ProSave or the device should be reset to factory settings. Existing data, user administration, recipes and licences should be backed up beforehand, as an OS update deletes data. After a successful restore, the project must be transferred again, and a new touchscreen calibration may also be required. Practical examples from the SPS Forum describe successful recovery of such panels using ProSave via Ethernet.
Why does system message 190004 appear: “The variable is not updated because the configured address for this variable does not exist”? Siemens clearly identifies 190004 as a configuration issue. Check the actual PLC address of the variable, the data type used, the controller type and any modified DB structures or offsets. Following changes to data blocks or alarm structures, the HMI configuration must match the PLC structure exactly. In practice, this means comparing addresses and data types carefully, correcting the project and then downloading the updated HMI project again.
Why are values not being written, or why does message 190007 appear indicating an interrupted connection? Siemens attributes 190007 to an interrupted connection to the controller or a variable that has been switched offline. Check the communication path itself, including Ethernet addressing, PROFIBUS/MPI parameters, physical cabling and the online status of the controller. In WinCC flexible environments, it should also be verified whether communication has been disabled by the SetOnline system function. Reliable read and write access to variables is only possible once communication has been fully restored.

Is 6AV6643-0CB01-1AX1 still available as a new unit?

The device should no longer be considered a standard new product. Siemens has classified this part number as blocked for new delivery since 1 January 2015. At the same time, EICHLER offers practical alternatives for this model, including repair, replacement, used units and new units on request. For purchasing and maintenance teams, this means that procurement is now typically based on service and spare-parts strategies rather than regular serial production supply.

Which software is required for 6AV6643-0CB01-1AX1?

The panel requires WinCC flexible 2005 Standard SP1 or later for configuration. Siemens explicitly states this in the current data sheet. The same documentation also notes that STEP 7 Basic and STEP 7 Professional in the TIA Portal are not intended as engineering tools for this device. For existing installations, this is important because the engineering strategy often determines the success of a repair, replacement or migration project.

Can I replace the MP 277 8" Touch directly with a TP900 Comfort?

Siemens identifies the TP900 Comfort as the migration path for the MP 277 8" Touch. However, it should not automatically be regarded as a direct 1:1 drop-in replacement. The migration guide highlights differences in display size, resolution and consequently project and installation requirements. For operators, this distinction is important: the TP900 Comfort is a suitable long-term successor platform, but for a quick replacement in an existing installation, the technical and project compatibility should be verified in advance.

Which interfaces does the panel provide for service and system integration?

The MP 277 8" Touch is equipped with 1 × Ethernet RJ45, 1 × RS422, 1 × RS485, 2 × USB ports and an MMC slot. Siemens also specifies support for PROFINET IO, PROFIBUS, TCP/IP and Modbus. This makes the panel particularly useful in existing installations because it can support both traditional and mixed communication architectures. For service applications, the USB ports, Ethernet interface and transfer functions are especially valuable for tasks such as backup, OS updates and project downloads.

Can I back up project data and the device status before repair or replacement?

Yes. Siemens provides a backup and restore function for the MP 277 using external storage media. This allows device data to be backed up and restored later if required. It is important to note that a restore operation deletes existing data on the panel, and licence keys may also be removed depending on the selected options. For maintenance and purchasing departments, creating a complete backup before removing the panel is highly recommended, as it simplifies recommissioning, replacement procedures and documentation.

Can the 6AV6643-0CB01-1AX1 communicate with an S7-1200 or S7-1500?

According to the Siemens data sheet, communication with both S7-1200 and S7-1500 controllers is supported. This means that communication is fundamentally possible. However, it is equally important to remember that the panel itself remains part of the WinCC flexible generation and is not engineered directly in the TIA Portal. In practice, a clear distinction should therefore be made between communication compatibility and engineering or migration compatibility.

Important documents

Repair accompanying note

Download the repair accompanying note as a PDF, or use the digital repair registration and send your defective modules to the EICHLER Service Centre for repair.

Laughing Eichler technician points to green PDF with special sale of automation technology

Your shopping basket

Loading shopping basket