SIEMENS 6AV2124-0QC02-0AX0

  • EICHLER-art.no.: K0323994
  • EAN: 4025515081210
  • UPC: 040892952407

Product description

SIMATIC HMI TP1500 COMFORT, COMFORT PANEL, TOUCH OPERATION, 15 WIDESCREEN-TFT-DISPLAY, 16 MIL. COLORS, PROFINET INTERFACE, MPI/PROFIBUS DP INTERFACE, 24 MB USER MEMORY, WINDOWS CE 6.0, CONFIGURABLE FROM WINCC COMFORT V11 SP2

Services for SIEMENS 6AV2124-0QC02-0AX0

Repair

1-3 days

from 1.715,84 €

to 3.088,50 €

per pc. 159,00 €

Replacement

1-3 days

7 Pcs.

4.402,80 €

per pc. 159,00 €

4.402,80 € *

Please enter an offer recipient here.


Used

1-3 days

7 Pcs.

4.892,00 €

per pc. 159,00 €

4.892,00 € *

Please enter an offer recipient here.


New

Delivery information
Export identifier AL: N ECCN: 5A992
Net weight 6.21
Quantity 1 Stück
Packaging quantity 1
Additional product information
Product status EOP: 2022-07-01
EAN 4025515081210
UPC 040892952407
Static lot number 85371091
List indicator ST9.80
Product group 4332
Country of origin DE
Compliance with the substance restrictions according to RoHS directive Since: 20120217
Product classifications Version Classification
eClass 4 /
eClass 5.1 27-24-23-02
eClass 6.0 27-24-23-02
ETIM 3 /
ETIM 4 EC001412
ETIM 5 EC001412

What is 6AV2124-0QC02-0AX0 and where is it used?

The 6AV2124-0QC02-0AX0 is a SIMATIC HMI TP1500 Comfort from Siemens and belongs to the Comfort Panel family designed for demanding visualisation tasks in machine and plant applications. The device features touch operation, a 15.4" widescreen TFT display with 16 million colours, and can be engineered from WinCC Comfort V11 SP2 onwards. In practice, the panel is used wherever operators need to monitor machine status, enter setpoints, acknowledge alarms, manage recipes or execute service functions. Typical applications include packaging machines, conveyor systems, manufacturing cells, networked PLC installations and retrofit projects in existing SIMATIC environments.

Overview of the key technical data and what they mean

The panel operates on 24 V DC with a permissible range of 19.2 to 28.8 V, providing stable power supply in industrial control cabinets. The 1280 × 800 pixel resolution on a 15.4-inch display offers a large visualisation area for alarm lists, trend curves and recipe screens. The analogue resistive touchscreen is robust and can be operated reliably with gloves or a stylus. Communication interfaces include PROFINET, MPI/PROFIBUS DP, two Industrial Ethernet ports plus an independent Ethernet port, USB 2.0 and two SD card slots. The device also supports backup/restore, project transfer via Ethernet, USB, MPI/PROFIBUS and external storage media. The protection rating is IP65 at the front and IP20 at the rear.

Product status, lifecycle status and obsolescence

For 6AV2124-0QC02-0AX0, the EICHLER shop lists the product status as EOP (End of Product) with an effective date of 01.07.2022. Siemens classifies the device as an earlier TP1500 Comfort version and identifies 6AV2124-0QC02-0AX1 as the verified successor, projectable from WinCC Comfort V14 SP1 onwards. Siemens documentation additionally references a PM490 target date of 01.10.2027 for this article number. For operators, this means that the panel remains technically relevant for many existing installations but is clearly in a phase where obsolescence management, spare-part strategy and repairability become increasingly important. Especially in validated legacy projects, a combination of existing hardware, repair options and planned replacement strategies is often more economical than an unplanned platform migration.

Available EICHLER services and when they are relevant

For 6AV2124-0QC02-0AX0, EICHLER offers repair, exchange, used units and new units on request. Repair is particularly relevant when an existing project must remain unchanged, the control cabinet installation must be retained or production downtime needs to be minimised without immediately migrating to a newer hardware platform. According to the shop information, repairs include technical cleaning, preventive maintenance, comprehensive functional testing and a minimum 24-month warranty. Exchange units and tested used devices are valuable when availability is the primary concern and a ready-to-install replacement is required. For purchasing and production departments, these options improve supply security even though the original product is already in the phase-out stage.

Attribute Value
Product type designation TP1500 Comfort
Display
Design of display TFT
Screen diagonal 15.4 in
Display width 331.2 mm
Display height 207 mm
Number of colors 16 777 216
Resolution (pixels)
● Horizontal image resolution 1 280 pixel
● Vertical image resolution 800 pixel
Backlighting
● MTBF backlighting (at 25 °C) 80 000 h
● Backlight dimmable Yes; 0-100 %
Control elements
Keyboard fonts
● Function keys
— Number of function keys 0
— Number of function keys with LEDs 0
● Keys with LED No
● System keys No
● Numeric keyboard Yes
● alphanumeric keyboard Yes
Touch operation
● Design as touch screen Yes; Analog-resistive
Expansions for operator control of the process
● Direct keys (touch buttons as S7 input I/O) 40
Installation type/mounting
Mounting position vertical
Wall mounting/direct mounting No
Mounting in portrait format possible Yes
Mounting in landscape format possible Yes
maximum permissible angle of inclination without external ventilation 35°
Supply voltage
Type of supply voltage DC
Rated value (DC) 24 V
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V
Input current
Current consumption (rated value) 1.5 A
Starting current inrush I²t 0.5 A²·s
Power
Active power input, typ. 36 W
Processor
Processor type X86
Memory
Flash Yes
RAM Yes
Memory available for user data 24 Mbyte
Type of output
Info LED No
Power LED No
Error LED No
Acoustics
● Buzzer No
● Speaker Yes
Time of day
Clock
● Hardware clock (real-time) Yes
● Software clock Yes
● retentive Yes; Back-up duration typically 6 weeks
● synchronizable Yes
Interfaces
Number of industrial Ethernet interfaces 2; 2 ports (switch) + independent port
Number of RS 485 interfaces 1; RS 422 / 485 combined
Number of RS 422 interfaces 0; together with RS 485
Number of RS 232 interfaces 0
Number of USB interfaces 2; USB 2.0
● USB Mini B 1; 5-pole
Number of 20 mA interfaces (TTY) 0
Number of parallel interfaces 0
Number of other interfaces 0
Number of SD card slots 2
With software interfaces No
Industrial Ethernet
● Industrial Ethernet status LED 3
● Number of ports of the integrated switch 2
Protocols
PROFINET Yes
Supports protocol for PROFINET IO Yes
IRT Yes; As of WinCC V12
PROFIBUS Yes
EtherNet/IP Yes
MPI Yes
Protocols (Ethernet)
● TCP/IP Yes
● DHCP Yes
● SNMP Yes
● DCP Yes
● LLDP Yes
WEB characteristics
● HTTP Yes
● HTTPS Yes
● HTML Yes
● XML Yes
● CSS Yes
● Active X Yes
● JavaScript Yes
● Java VM No
Redundancy mode
Media redundancy
— MRP Yes
Further protocols
● CAN No
● MODBUS Yes
Interrupts/diagnostics/status information
Diagnoses
● Diagnostic information readable Yes; S7 controller
EMC
Emission of radio interference acc. to EN 55 011
● Limit class A, for use in industrial areas Yes
● Limit class B, for use in residential areas No
Degree and class of protection
IP (at the front) IP65
IP (rear) IP20
NEMA (front)
● Enclosure Type 4 at the front Yes
● Enclosure Type 4x at the front Yes
Standards, approvals, certificates
CE mark Yes
cULus Yes
RCM (formerly C-TICK) Yes
KC approval Yes
Use in hazardous areas
● ATEX Zone 2 No
● ATEX Zone 22 No
● IECEx Zone 2 No
● IECEx Zone 22 No
● cULus Class I Zone 1 No
● cULus Class I Zone 2, Division 2 Yes
● FM Class I Division 2 Yes
Marine approval
● Germanischer Lloyd (GL) No
● American Bureau of Shipping (ABS) No
● Bureau Veritas (BV) No
● Det Norske Veritas (DNV) No
● Lloyds Register of Shipping (LRS) No
● Nippon Kaiji Kyokai (Class NK) No
● Polski Rejestr Statkow (PRS) No
Ambient conditions
Ambient temperature during operation
Operation (vertical installation)
— For vertical installation, min. 0 °C
— For vertical installation, max. 50 °C; (55 °C, see entry ID: 64847814)
Operation (max. tilt angle)
— At maximum tilt angle, min. 0 °C
— At maximum tilt angle, max. 40 °C
Operation (vertical installation, portrait format)
— For vertical installation, min. 0 °C
— For vertical installation, max. 40 °C
Operation (max. tilt angle, portrait format)
— At maximum tilt angle, min. 0 °C
— At maximum tilt angle, max. 40 °C
Ambient temperature during storage/transportation
● min. -20 °C
● max. 60 °C
Relative humidity
● Operation, max. 90 %; no condensation
Operating systems
proprietary No
pre-installed operating system
● Windows CE Yes
Configuration
Message indicator Yes
Alarm system (incl. buffer and acknowledgment) Yes
Process value display (output) Yes
Process value default (input) possible Yes
Recipe management Yes
Configuration software
● STEP 7 Basic (TIA Portal) No
● STEP 7 Professional (TIA Portal) No
● WinCC flexible Compact No
● WinCC flexible Standard No
● WinCC flexible Advanced No
● WinCC Basic (TIA Portal) No
● WinCC Comfort (TIA Portal) Yes; V11 SP2 or higher
● WinCC Advanced (TIA Portal) Yes; V11 SP2 or higher
● WinCC Professional (TIA Portal) Yes; V11 SP2 or higher
Languages
Online languages
● Number of online/runtime languages 32
Project languages
● Languages per project 32
Functionality under WinCC (TIA Portal)
Libraries Yes
Applications/options
● Web browser Yes
● Pocket Word Yes
● Pocket Excel Yes
● PDF Viewer Yes
● Media Player Yes
● SIMATIC WinCC Sm@rtServer Yes
● SIMATIC WinCC Audit Yes
Number of Visual Basic Scripts Yes
Task planner
● time-controlled Yes
● task-controlled Yes
Help system
● Number of characters per info text 320
Message system
● Number of alarm classes 32
● Bit messages
— Number of bit messages 6 000
● Analog messages
— Number of analog messages 200
● S7 alarm number procedure Yes
● System messages HMI Yes
● System event, more (SIMATIC S7, SINUMERIK, SIMOTION, ... ) Yes
● Number of characters per message 80
● Number of process values per message 8
● Acknowledgment groups Yes
● Message indicator Yes
● Message buffer
— Number of entries 1 024
— Circulating buffer Yes
— retentive Yes
— maintenance-free Yes
Recipe management
● Number of recipes 500
● Data records per recipe 1 000
● Entries per data record 2 000
● Size of internal recipe memory 4 Mbyte
● Recipe memory expandable Yes
Variables
● Number of variables per device 4 096
● Number of variables per screen 400
● Limit values Yes
● Multiplexing Yes
● Structures Yes
● Arrays Yes
Images
● Number of configurable images 750
● Permanent window/default Yes
● Global image Yes
● Pop-up images Yes
● Slide-in images Yes
● Image selection by PLC Yes
● Image number in the PLC Yes
Image objects
● Number of objects per image 600
● Text fields Yes
● I/O fields Yes
● Graphic I/O fields (graphics list) Yes
● Symbolic I/O fields (text list) Yes
● Date/time fields Yes
● Switches Yes
● Buttons Yes
● Graphic display Yes
● Icons Yes
● Geometric objects Yes
Complex image objects
● Number of complex objects per screen 40
● Alarm view Yes
● Trend view Yes
● User view Yes
● Status/control Yes
● Sm@rtClient view Yes
● Recipe view Yes
● f(x) trend view Yes
● System diagnostics view Yes
● Media Player Yes
● HTML browser Yes
● PDF display Yes
● IP camera display Yes
● Bar graphs Yes
● Sliders Yes
● Pointer instruments Yes
● Analog/digital clock Yes
Lists
● Number of text lists per project 500
● Number of entries per text list 500
● Number of graphics lists per project 500
● Number of entries per graphics list 500
Archiving
● Number of archives per device 50
● Number of entries per archive 50 000
● Message archive Yes
● Process value archive Yes
● Archiving methods
— Sequential archive Yes
— Short-term archive Yes
● Memory location
— Memory card Yes
— USB memory Yes
— Ethernet Yes
● Data storage format
— CSV Yes
— TXT Yes
— RDB Yes
Security
● Number of user groups 50
● Number of user rights 32
● Number of users 50
● Password export/import Yes
● SIMATIC Logon Yes
Logging through printer
● Alarms Yes
● Report (shift log) Yes
● Hardcopy Yes
● Electronic print to file Yes; PDF, HTML
Character sets
● Keyboard fonts
— US English Yes
Transfer (upload/download)
● MPI/PROFIBUS DP Yes
● USB Yes
● Ethernet Yes
● using external storage medium Yes
Process coupling
● S7-1200 Yes
● S7-1500 Yes
● S7-200 Yes
● S7-300/400 Yes
● LOGO! Yes
● WinAC Yes
● SINUMERIK Yes; with SINUMERIK option package
● SIMOTION Yes
● Allen Bradley (EtherNet/IP) Yes
● Allen Bradley (DF1) Yes
● Mitsubishi (MC TCP/IP) Yes
● Mitsubishi (FX) Yes
● OMRON (FINS TCP) No
● OMRON (LINK/Multilink) Yes
● Modicon (Modbus TCP/IP) Yes
● Modicon (Modbus) Yes
● OPC UA Client Yes
● OPC UA Server Yes
Service tools/configuration aids
● Backup/Restore manually Yes
● Backup/Restore automatically Yes
● Simulation Yes
● Device switchover Yes
Peripherals/Options
Printer Yes
SIMATIC HMI MM memory card: Multi Media Card Yes; Up to 128 MB
SIMATIC HMI SD memory card: Secure Digital memory card Yes; Up to 2 GB
SIMATIC HMI CF memory card Compact Flash Card No
USB memory Yes
SIMATIC IPC USB Flashdrive (USB stick) Yes; Up to 16 GB
SIMATIC HMI USB stick Yes; Up to 8 GB
Network camera Yes
Mechanics/material
Enclosure material (front)
● Plastic No
● Aluminum Yes
● Stainless steel No
Dimensions
Width of the housing front 415 mm
Height of housing front 310 mm
Mounting cutout, width 396 mm
Mounting cutout, height 291 mm
mounting depth 75 mm
Weights
Weight (without packaging) 5.2 kg

Fault description Possible solution
Why is no transfer to the TP1500 Comfort possible although the panel responds to ping? First check whether the panel is actually in transfer mode and whether Enable Transfer is activated. Then ensure that the PG/PC interface, PN/IE or Ethernet settings, IP address, subnet mask and, if applicable, gateway settings match on the engineering PC, project and panel. Siemens also recommends ruling out duplicate IP addresses and using Accessible devices or Extended download for verification.
Why does the touchscreen respond inaccurately or at the wrong position? On the TP1500 Comfort, parallax effects can occur depending on the installation position and viewing angle. Siemens recommends recalibrating the touchscreen via Control Panel > OP Properties > Touch > Recalibrate. The calibration is performed using a stylus and is only saved if the touchscreen is confirmed within the specified time in the final confirmation dialog.
Why does the display remain black or very dim although the panel is still running? First check whether a screen saver or brightness setting is active rather than a hardware fault. Siemens states that when the Blank Screen screen saver is used, display brightness behaviour can be parameterised and the setting only becomes effective after a restart. If content can still be faintly recognised under side lighting or the panel remains operable, this indicates a backlight or display-control issue rather than a complete device failure.
Why does the panel fail to start correctly or become stuck after errors? Siemens recommends performing a reset via Prepare for Reset followed by an OS update using ProSave. The device is switched into download mode, the operating system is reloaded and, if required, restored to factory settings. Before starting, back up user administration data, recipes and any licence keys. The panel’s MAC address is also required for the procedure.
Why does TIA not reliably detect the panel via network or WLAN? Check that the correct network adapter is selected on the PG/PC, that the connection to the target subnet is correct and that the appropriate transfer path has been chosen. Siemens recommends displaying all compatible devices when in doubt and comparing the detected parameters with the settings configured on the panel. Practical service experience also shows that panel access via WLAN can behave differently from CPU access; for transfer and diagnostics, a direct and properly configured Ethernet connection is usually the more reliable solution.

What is the difference between 6AV2124-0QC02-0AX0 and 6AV2124-0QC02-0AX1?

According to Siemens, 6AV2124-0QC02-0AX0 is a Comfort V1 device, while 6AV2124-0QC02-0AX1 belongs to the subsequent V2 generation. Siemens explicitly identifies -0AX1 as the successor to -0AX0. This is important for procurement because, although both devices belong to the same TP1500 Comfort class, the successor must be considered a newer hardware revision in terms of engineering compatibility and spare-part strategy. For existing projects, it is therefore essential to verify which project version and TIA Portal/WinCC version are currently in use.

Which engineering software is required for 6AV2124-0QC02-0AX0?

Siemens specifies project engineering support for 6AV2124-0QC02-0AX0 from WinCC Comfort V11 SP2 onwards. WinCC Advanced and WinCC Professional are also supported from the same release level. In practice, this is particularly relevant when loading an existing project onto a replacement device or creating a backup before repair. If a migration to the official successor 6AV2124-0QC02-0AX1 is planned, Siemens specifies V14 SP1 as the minimum engineering version.

Which controllers and protocols are supported by the TP1500 Comfort?

On the communication side, the panel supports PROFINET, MPI/PROFIBUS DP, EtherNet/IP and MODBUS. For process connectivity, Siemens lists compatibility with S7-1200, S7-1500, S7-300/400, LOGO!, SINUMERIK, SIMOTION and additional systems. This is particularly valuable for maintenance and retrofit projects because the panel can be integrated not only into traditional SIMATIC environments but also into mixed automation architectures. The ability to access diagnostic information from S7 controllers also simplifies troubleshooting.

Can I transfer an existing project to a replacement device?

In principle, yes. The TP1500 Comfort supports project transfer via Ethernet, USB, MPI/PROFIBUS and external storage media. Siemens also provides both manual and automatic backup/restore functions. For a smooth device replacement, however, the project version, image version, communication parameters and, where applicable, user data, recipes and licence information should be backed up carefully. In legacy installations, it is advisable to organise backups before a failure occurs rather than waiting for an unexpected breakdown.

Is 6AV2124-0QC02-0AX0 still worth repairing, or should it be replaced directly?

For this article, repair and replacement should generally be viewed as complementary elements of the same support strategy rather than mutually exclusive options. The EICHLER portfolio lists repair, exchange, used units and new units on request, while the product's EOP status and official successor have already been documented. As a result, repair is often the preferred option when the existing project must remain unchanged, whereas replacement is advantageous when downtime costs are the overriding concern and an immediate spare unit is required. For critical systems, the combination of a repaired original device and an additional replacement unit is often the lowest-risk approach.

Which installation and environmental conditions should be considered?

The panel is rated IP65 at the front and IP20 at the rear. Siemens specifies an operating temperature range of 0 to 50 °C for vertical landscape installation, while installations with maximum inclination or portrait orientation are limited to 0 to 40 °C. The device also includes two SD card slots, USB, Ethernet and a range of runtime functions. For engineering and procurement teams, this means that not only the article number but also the actual installation environment, thermal conditions and accessibility for service, backup and project transfer must be considered when selecting a replacement device.