SIEMENS 6AV6542-0AG10-0AX0
-
SIEMENS | HMI | Operator Panels
- EICHLER-art.no.: K0116915
- EAN: 4025515068013
Product description
SIMATIC MP270B TASTEN MULTI PANEL 10,4" TFT DISPLAY 4 MB PROJEKTIERUNGSSPEICHER, PROJEKTIERBAR MIT PROTOOL AB VERSION V6.0
Services for SIEMENS 6AV6542-0AG10-0AX0
Repair
from 1.590,72 €
to 2.863,30 €
Replacement
3.045,60 €
Used
3.384,00 €
New
6.112,00 €
SIEMENS |
6AV6542-0AG10-0AX0 –
additional product information
| Delivery information | |||
|---|---|---|---|
| Export identifier | AL: ECCN: | ||
| Net weight | 6 | ||
| Quantity | 1 Stück | ||
| Packaging quantity | 1 | ||
| Additional product information | |||
|---|---|---|---|
| Product status | EOP: 2008-04-01 | ||
| EAN | 4025515068013 | ||
| UPC | / | ||
| Static lot number | 85371099 | ||
| List indicator | / | ||
| Product group | / | ||
| Country of origin | / | ||
| Compliance with the substance restrictions according to RoHS directive | Since: / | ||
| Product classifications | Version | Classification | |
|---|---|---|---|
| eClass | 4 | / | |
| eClass | 5.1 | / | |
| eClass | 6.0 | / | |
| ETIM | 3 | / | |
| ETIM | 4 | / | |
| ETIM | 5 | / | |
What is the 6AV6542-0AG10-0AX0 and where is it used?
The 6AV6542-0AG10-0AX0 is a SIEMENS SIMATIC MP270B Key Multi Panel. It is a 10.4-inch HMI with TFT display and keypad operation designed for the visualisation, operation and monitoring of machines and industrial systems. Typical applications include production lines, packaging machinery, conveyor systems, process plants and retrofit projects where a robust local operator interface with dedicated function keys is required. In existing installations, this panel is often closely linked to the original project configuration, panel cut-out and operating procedures. For maintenance and purchasing departments, the part number is therefore often the fastest way to identify the correct spare part, repair option or exchange solution.
Overview of the key technical data and their significance
The panel features a 10.4-inch TFT display, 4 MB project memory and can be engineered using ProTool from Version V6.0. In practice, this places the device within the generation of classic Siemens HMIs that are still widely used in long-running industrial installations with established software environments. Power is supplied via 24 V DC, with an allowable range of 20.4 to 28.8 V DC, and the specified operating temperature range is 0 to 50 °C. The front protection rating is IP65 / NEMA 4X Indoor / NEMA 12, while the rear protection rating is IP20. For operation, the 10-inch Key version provides F1 to F20 and K1 to K16 keys. Siemens also specifies support for CF cards, PC cards, Ethernet and USB-based transfer and storage functions, which are particularly important for backup procedures, project transfer and service activities.
Product status, lifecycle status and obsolescence
For 6AV6542-0AG10-0AX0, EICHLER lists a product status of EOP (End of Production): 01 April 2008. Siemens classifies the device as a spare part, which clearly indicates that it is no longer part of a current product generation. For plant operators, this means that procurement decisions should consider obsolescence management, availability risks and downtime prevention strategies. A verified Siemens successor within the 10-inch product range is the SIMATIC MP 277 10" Key. Siemens explicitly identifies the MP 277 10" Key as the successor platform for previous MP270B 10-inch devices and states that MP270B and TP/OP270 10-inch projects can be migrated in WinCC flexible using a device change procedure. This provides an important migration path for modernisation and retrofit projects.
Available EICHLER services and when they are relevant
When production must be restored quickly, repair is often the most effective option because the existing operating concept, installation dimensions and project configuration can remain unchanged. EICHLER describes its repair service for this panel as including technical cleaning, preventive maintenance, comprehensive functional testing and a minimum 24-month warranty. For critical downtime situations, exchange units are available, typically with turnaround times of 1–3 days. In addition, used and new units are available for this article number, and an optional test report can be supplied to support documentation requirements in purchasing departments or quality-critical industries. For obsolete HMIs in particular, these service options help maintain machine availability beyond the original production lifecycle while reducing spare-parts and procurement risks.
| Attribute | Value |
|---|---|
| Display | |
| Design of display | TFT, 256 colors |
| Screen diagonal | 10.4 in |
| Resolution (pixels) | |
| ● Horizontal image resolution | 640 Pixel |
| ● Vertical image resolution | 480 Pixel |
| Backlighting | |
| ● MTBF backlighting (at 25 °C) | 50 000 h |
| Control elements | |
| Control elements | Membrane keyboard |
| Keyboard fonts | |
| ● Membrane keyboard | Yes |
| — user-definable label membrane keys | Yes |
| ● Function keys | |
| — Number of function keys | 36 |
| — Number of function keys with LEDs | 28 |
| ● System keys | |
| — Number of system keys | 38 |
| ● Numeric keyboard | Yes |
| ● alphanumeric keyboard | Yes |
| ● hexadecimal keyboard | Yes |
| ● Multi-key operation | Yes |
| — Number of multi-key operations | 28 |
| Touch operation | |
| ● Design as touch screen | No |
| Connection type | |
| ● Type of connection for mouse/keyboard/barcode reader | USB / USB / USB |
| Special operator controls | |
| ● Illuminated pushbutton | Yes |
| Installation type/mounting | |
| Mounting position | vertical |
| maximum permissible angle of inclination without external ventilation | 35° |
| Supply voltage | |
| UPS connectable (serial) | Yes |
| Input current | |
| Current consumption (rated value) | 0.9 A |
| Starting current inrush I²t | 0.5 A²·s |
| Power | |
| Active power input, typ. | 22 W |
| Processor | |
| Processor type | RISC 32 bit |
| Memory | |
| Type of memory | Flash / RAM |
| Memory available for user data | 4 096 kbyte |
| Battery | |
| Backup battery | |
| ● Backup battery (optional) | Yes; optional 3.6 V |
| ● Backup time, min. | 3 y |
| Type of output | |
| Info LED | Yes |
| Power LED | No |
| Error LED | Yes |
| Time of day | |
| Clock | |
| ● Type | Hardware clock, battery backup, synchronizable |
| ● retentive | Yes |
| ● synchronizable | Yes |
| Interfaces | |
| Interfaces/bus type | 2x RS 232, 1x RS 422, 1x RS 485, 1x Ethernet (RJ45) (max. 12 Mbit/s) |
| USB port | Yes; 1x USB |
| PC card slot | 1x PC card slot |
| CF card slot | 1x CF card slot |
| Degree and class of protection | |
| IP (at the front) | IP65 |
| IP (rear) | IP20 |
| Standards, approvals, certificates | |
| Certificate of suitability | CE, GL, ABS, DNV, LRS, FM Class I Div. 2, cULus, EX Zone 2/22, C-TICK |
| Ambient conditions | |
| Ambient temperature during storage/transportation | |
| ● min. | -20 °C |
| ● max. | 60 °C |
| Relative humidity | |
| ● Operation, max. | 90 % |
| Operating systems | |
| pre-installed operating system | Windows CE |
| Configuration | |
| Configuration software | |
| ● Configuration tool | ProTool Version 6 SP 3 or higher, or WinCC flexible Standard Version 2004 or higher (to be ordered separately) |
| Languages | |
| Online languages | |
| ● Number of online/runtime languages | 5 |
| Project languages | |
| ● Languages per project | 32 |
| Functionality under WinCC (TIA Portal) | |
| Libraries | Yes |
| Number of Visual Basic Scripts | |
| ● Debugging in the simulator | No |
| Task planner | Yes |
| Help system | Yes |
| ● Number of characters per info text | 70 |
| ● Number of tooltips | 0 |
| Message system | |
| ● Number of alarm classes | 32 |
| ● Number of messages | 4 000 |
| ● Bit messages | Yes |
| — Number of bit messages | 4 000 |
| ● Analog messages | Yes |
| — Number of analog messages | 4 000 |
| ● Telegram message procedure Alarm S | Yes |
| ● System messages HMI | Yes |
| ● System messages PLC | Yes |
| ● System messages, other (SIMATIC S7, Sinumerik, Simotion, etc.) | Yes |
| ● Lines | 1 |
| ● Number of characters per message | 70 |
| ● Number of process values per message | 8 |
| ● Acknowledgment groups | Yes |
| ● Message indicator | Yes |
| ● acoustic feedback | No |
| ● First/last value | Yes |
| Recipe management | |
| ● Number of recipes | 300 |
| ● Data records per recipe | 500 |
| ● Entries per data record | 1 000 |
| ● Recipe memory | 64 KB integrated Flash, expandable |
| Variables | |
| ● Number of variables per device | 2 048 |
| ● Number of variables per screen | 200 |
| ● Number of variables | 1 000 |
| ● Initial values | 2 048 |
| ● Type Date & Time | 2 048 |
| ● Limit values | Yes |
| ● Multiplexing | Yes |
| ● Structures | Yes |
| Images | |
| ● Number of configurable images | 500 |
| ● Permanent window/default | Yes |
| ● Start screen configurable | Yes |
| ● Image selection by PLC | Yes |
| ● Image number in the PLC | Yes |
| Image objects | |
| ● Text objects | 10 000 text elements |
| ● Number of I/O fields per image | 200 |
| ● Number of date/time fields | 200 |
| ● Index of screen context | No |
| ● Return | Yes |
| ● Graphics object | Bit maps, icons, vector graphics |
| — Icons | 1 000 |
| — Icon (full screen) | 0 |
| Complex image objects | |
| ● Status/control | With SIMATIC S7 |
| ● dynamic objects | Diagrams, bar graphs, sliders, analog display, invisible buttons |
| — Number of objects per project | 1 000 |
| — Number of curve diagrams per image | 10 |
| ● Methods | Trend / profile |
| ● Bar graphs | |
| — Number of bars per chart | 10 |
| ● Sliders | |
| — Number of slides per image | 10 |
| ● Pointer instruments | |
| — Number of analog indicators per image | 10 |
| ● Limit value lines | Yes |
| ● Number of alphanumerical fields | 300 |
| — alphanumeric fields per image | 200 |
| ● Number of numerical fields | 2 048 |
| — numerical fields per image | 200 |
| ● Number of password fields | 2 048 |
| ● Number of visible switches per project | 200 |
| — visible switches per image | 200 |
| — hidden switches per image | 200 |
| ● Number of status switches per project | 200 |
| — Number of status switches per image | 200 |
| ● Number of selector switches per project | 200 |
| — Selector switches per image | 200 |
| ● Number of decade switches per project | 200 |
| — Decade switches per image | 200 |
| ● Number of signal lamps per project | 200 |
| — Signal lamps per image | 200 |
| Attributes for dynamic objects | |
| ● Color change | Yes |
| ● X/Y movement | Yes |
| ● Hide | Yes |
| ● Angle of rotation | No |
| Lists | |
| ● Number of text lists per project | 500 |
| ● Number of text lists per image | 200 |
| ● Number of entries per text list | 256 |
| ● Number of graphics lists per project | 400 |
| ● Number of graphic lists per image | 200 |
| ● Number of entries per graphics list | 256 |
| Archiving | |
| ● Number of archives per device | 20 |
| ● Number of measuring points per project | 20 |
| ● Number of entries per archive | 10 000 |
| ● Message archive | Yes |
| ● Process value archive | Yes |
| ● Archiving methods | Sequential log, circular log, alarm log, process value archive |
| — Sequential archive | Yes |
| — Short-term archive | Yes |
| ● Memory location | PC card, CF card, Ethernet |
| — PC card | Yes |
| — CF card | Yes |
| — USB memory | No |
| — Ethernet | Yes |
| ● Data storage format | CSV file, readable, e.g. with MS Excel, MS Access |
| — CSV | Yes |
| — TXT | No |
| ● external evaluation | readable, e.g. with MS Excel, MS Access, etc. |
| ● Size of archive | depending on free memory on ext. card/stick or on free hard disk space via network drive |
| ● Online evaluation | via trends |
| — using trend curves | Yes |
| Filters | |
| ● cyclic | Yes |
| ● Tolerance | Yes |
| ● Change | Yes |
| Security | |
| ● Number of user groups | 50 |
| ● Number of user rights | 32 |
| ● Password export/import | Yes |
| Logging through printer | |
| ● Recording/Printing | Alarms, report (shift report), color print, hardcopy |
| Transfer (upload/download) | |
| ● Transfer of configuration | MPI/PROFIBUS DP, serial, USB, Ethernet, by means of external storage medium, automatic transfer recognition |
| Process coupling | |
| ● Connection to controller | S5, S7-200, S7- 300/400, TI 505, Win AC, PC (TCP/IP), SINUMERIK, SIMOTION, Allen Bradley (DF1), Allen Bradley (DF485), Mitsubishi (FX), Telemecanique (ADJUST), OMRON (LINK/Multilink), Modicon (Modbus), for further non-Siemens drivers, see section on "System interfaces" |
| ● S7-200 | Yes |
| — PPI (point-to-point) | Yes |
| — PPI network | Yes |
| — MPI | Yes |
| — PROFIBUS DP | Yes |
| ● S7-300/400 | Yes |
| — MPI | Yes |
| — PROFIBUS DP | Yes |
| — PROFINET | Yes |
| ● S5 | Yes |
| — serial | Yes |
| — PROFIBUS DP | Yes |
| ● TI 505 | Yes |
| ● Allen Bradley (DF1) | Yes |
| ● Allen Bradley (DF485) | Yes |
| ● Mitsubishi (FX) | Yes |
| ● Mitsubishi (MP4) | Yes |
| ● Telemecanique (ADJUST) | Yes |
| ● Telemecanique (Uni-Telway) | Yes |
| ● OMRON (LINK/Multilink) | Yes |
| ● Modicon (Modbus) | Yes |
| ● GE-Fanuc (SNP) | Yes |
| Functions | |
| ● Key repeat | No |
| ● TAB sequence | Yes |
| ● Calculating functions | Yes |
| ● Animate | Yes |
| ● Menu tree editor | No |
| ● Unit switchover | No |
| Service tools/configuration aids | |
| ● Clean screen | No |
| ● Touch calibration | No |
| ● Backup/Restore manually | Yes |
| ● Simulation | Yes |
| ● Device switchover | Yes |
| ● Delta transfer | Yes |
| ● Monitoring function for battery and memory | Yes |
| ● Trace (operation archive) | No |
| Expandability/openness | |
| ● Open Platform Program | Yes |
| Peripherals/Options | |
| Peripherals | Printer, barcode reader |
| Dimensions | |
| Width of the housing front | 483 mm |
| Height of housing front | 310 mm |
| Overall depth | 55 mm |
| Weights | |
| Weight (without packaging) | 6 kg |
| Fault description | Possible solution |
|---|---|
| Why can't I establish a transfer to the MP270B via MPI, USB or serial connection? | First check whether the correct transfer channel is activated on the panel and whether the Remote Control option is enabled for the selected channel. Then verify that the address, baud rate, highest station address and, if applicable, the "Only master on the bus" setting match between the PG/PC interface, the project and the panel. Using the correct cable is also essential, especially for serial connections. Siemens specifies transfer via serial, MPI, Ethernet and USB. The panel must be in Transfer Mode. |
| Why does my MP270B stop during boot-up after a power failure? | A startup freeze after a power interruption is a common service issue. A practical approach is to restore the device using ProSave or, if necessary, perform an operating system recovery. Ensure that a valid project backup is available beforehand, as a reset may remove the application. For Windows-based panels, Siemens explicitly describes Backup/Restore as a fast recovery method after system faults or device replacement. |
| What does error message 210005 "PLC job invalid" mean on the MP270B? | According to Siemens, this system message indicates that an invalid job number has been entered in the job mailbox. Check the PLC program, especially the transfer of job numbers and the associated parameters. If the message occurs in connection with recipes or operator jobs, also verify the recipe number, record number and the reset of the status word so that the next job can start correctly. |
| Why are recipes or data records not transferred completely on the MP270B? | Siemens lists several common causes: PLC addresses not configured in the project, overwriting of existing records not permitted, a non-existent recipe number or an invalid record number. After a failed transfer, the status word in the PLC program must be reset to 0 before additional transfers can be executed. Without this reset, subsequent jobs often remain blocked or immediately generate another error. |
| Why can't the alarm window on the MP270B Key be closed? | On the MP270B Key, the alarm window can only be closed once all displayed alarms have been acknowledged. If the window remains open, acknowledge all active alarms and verify that the acknowledgement logic has been implemented correctly in both the project and the PLC program. For migrated or modified projects, it is also advisable to review the alarm classes and alarm display configuration. |
Is 6AV6542-0AG10-0AX0 still available or already discontinued?
6AV6542-0AG10-0AX0 clearly falls into the category of discontinued and obsolescence-affected legacy devices. EICHLER lists the device with an EOP status of 01/04/2008, while Siemens classifies the part number as a spare part. In practical procurement terms, the focus is no longer on series-production new units but on repair, exchange, used equipment, refurbished units and remaining stock availability. For operators of older systems, a proactive spare-parts strategy is therefore highly recommended.
Which software is required for 6AV6542-0AG10-0AX0?
Siemens explicitly specifies ProTool Version V6.0 or higher for this article number. This is important because many MP270B installations still originate from the ProTool engineering environment, making modifications impossible without the appropriate engineering software. For modernisation projects, Siemens additionally lists the MP270B 10" Key as a migratable device in the WinCC flexible migration documentation. Anyone planning project modifications, backups or device replacements should therefore first verify the available project data and engineering version.
Is there a compatible successor for the MP270B Key 10.4"?
Yes. Siemens positions the MP 277 10" Key as the successor platform for the previous MP270B 10" devices. Siemens also states that MP270B and TP/OP270 10" projects can be transferred to an MP 277 via a device change in WinCC flexible with full compatibility. Mechanical compatibility is also relevant, as Siemens documentation specifies compatible panel cut-outs between the MP270B 10" Key and the MP 277 10" Key, reducing retrofit effort significantly.
When is repair more economical than replacement for 6AV6542-0AG10-0AX0?
Repair is particularly worthwhile when the existing project configuration, panel cut-out and operating concept should remain unchanged. In existing installations, this is often the fastest way to avoid additional costs associated with modification, migration and recommissioning. EICHLER states that repairs include technical cleaning, preventive maintenance, comprehensive functional testing and a minimum 24-month warranty. An exchange unit is more suitable when downtime is critical and an immediately available replacement device is required.
Can I back up the existing project or restore it to a replacement device?
Yes, this is generally possible, although it depends on the engineering version and the transfer method previously used. Siemens explicitly describes Backup/Restore for Windows-based panels such as the MP270B as a method for rapid recovery after a system fault or device replacement. Depending on the engineering environment, transfer, reverse transfer and Backup/Restore functions are supported via ProSave, ProTool and WinCC flexible. Before any replacement, it is therefore essential to verify that a current and functional project backup is available.