| Product type designation |
PP17-I |
| Control elements |
|
| With parameterizable keys |
Yes |
| Keyboard fonts |
|
| ● Membrane keyboard |
|
| — user-definable label membrane keys |
Yes |
| ● Function keys |
|
| — Number of function keys |
16 |
| ● Short-stroke keys |
|
| — Number of short-stroke keys |
16 |
| Expansions for operator control of the process |
|
| ● DP direct LEDs (LEDs as S7 output I/O) |
16 |
| ● Number of color modes for LED |
3 |
| ● Direct keys (keys as S7 input I/O) |
16 |
| Installation type/mounting |
|
| Mounting type |
Clamp terminals |
| Mounting position |
vertical |
| Rack mounting |
No |
| Front mounting |
Yes |
| Rail mounting |
No |
| Wall mounting/direct mounting |
No |
| Mounting in portrait format possible |
No |
| Mounting in landscape format possible |
Yes |
| maximum permissible angle of inclination without external ventilation |
35° |
| Number of slots for command devices and signaling units |
12 |
| Supply voltage |
|
| Type of supply voltage |
DC |
| permissible range, lower limit (DC) |
18 V |
| permissible range, upper limit (DC) |
30 V |
| Input current |
|
| Starting current inrush I²t |
0.03 A²·s |
| Digital inputs |
|
| Number of digital inputs |
16 |
| Input voltage |
|
| ● Rated value (DC) |
24 V |
| Digital outputs |
|
| Number of digital outputs |
16 |
| ● in groups of |
4 |
| Short-circuit protection |
Yes |
| Switching capacity of the outputs |
|
| ● with resistive load, max. |
100 mA |
| ● with inductive load, max. |
100 mA; max. 2 watts |
| ● on lamp load, max. |
2 W |
| Output voltage |
|
| ● Rated value (DC) |
24 V |
| Total current of the outputs |
|
| ● Current per channel, max. |
100 mA |
| ● Current per group, max. |
500 mA |
| Interfaces |
|
| Number of industrial Ethernet interfaces |
0 |
| Number of PROFINET interfaces |
0 |
| Industrial Ethernet |
|
| ● Industrial Ethernet status LED |
0 |
| ● Number of ports of the integrated switch |
0 |
| Protocols |
|
| PROFINET |
No |
| Supports protocol for PROFINET IO |
No |
| PROFINET CBA |
No |
| IRT |
No |
| PROFIsafe |
No |
| PROFIBUS |
Yes |
| EtherNet/IP |
No |
| MPI |
Yes |
| AS-Interface |
No |
| EIB/KNX |
No |
| Protocols (Ethernet) |
|
| ● TCP/IP |
No |
| Redundancy mode |
|
| Media redundancy |
|
| — MRP |
No |
| Further protocols |
|
| ● AS-Interface Safety at Work |
No |
| ● CAN |
No |
| ● Data-Highway |
No |
| ● DeviceNet |
No |
| ● DeviceNet Safety |
No |
| ● Foundation Fieldbus |
No |
| ● INTERBUS |
No |
| ● INTERBUS-Safety |
No |
| ● Local Operating Network |
No |
| ● MODBUS |
No |
| ● SafetyBUS p |
No |
| ● SERCOS |
No |
| ● SUCOnet |
No |
| ● other bus systems |
No |
| Test commissioning functions |
|
| Illuminant test |
Yes |
| Key and signal lamp test |
Yes; automatically when switching on |
| EMC |
|
| Emission of radio interference acc. to EN 55 011 |
|
| ● Limit class A, for use in industrial areas |
Yes |
| ● Limit class B, for use in residential areas |
No |
| Degree and class of protection |
|
| IP (at the front) |
IP65 |
| IP (rear) |
IP20 |
| NEMA (front) |
|
| ● Enclosure Type 4 at the front |
No |
| ● Enclosure Type 4x at the front |
No |
| Standards, approvals, certificates |
|
| CE mark |
Yes |
| cULus |
No |
| RCM (formerly C-TICK) |
No |
| KC approval |
No |
| Suitable for safety functions |
No |
| Use in hazardous areas |
|
| ● ATEX Zone 2 |
No |
| ● ATEX Zone 22 |
No |
| ● cULus Class I Zone 1 |
No |
| ● cULus Class I Zone 2, Division 2 |
No |
| ● FM Class I Division 2 |
No |
| Marine approval |
|
| ● Germanischer Lloyd (GL) |
No |
| ● American Bureau of Shipping (ABS) |
No |
| ● Bureau Veritas (BV) |
No |
| ● Det Norske Veritas (DNV) |
No |
| ● Lloyds Register of Shipping (LRS) |
No |
| ● Nippon Kaiji Kyokai (Class NK) |
No |
| ● Polski Rejestr Statkow (PRS) |
No |
| Ambient conditions |
|
| Ambient temperature during operation |
|
| ● min. |
0 °C |
| ● max. |
55 °C |
| Operation (vertical installation) |
|
| — For vertical installation, min. |
0 °C |
| — For vertical installation, max. |
55 °C |
| Operation (max. tilt angle) |
|
| — At maximum tilt angle, min. |
0 °C |
| — At maximum tilt angle, max. |
55 °C |
| Ambient temperature during storage/transportation |
|
| ● min. |
-20 °C |
| ● max. |
60 °C |
| Relative humidity |
|
| ● Operation, max. |
95 % |
| configuration / header |
|
| Configuration software |
|
| ● STEP 7 Basic (TIA Portal) |
Yes |
| ● STEP 7 Professional (TIA Portal) |
Yes |
| Functionality under WinCC (TIA Portal) |
|
| Process coupling |
|
| ● S7-1200 |
Yes |
| ● S7-1500 |
Yes |
| ● S7-200 |
No |
| ● S7-300/400 |
Yes |
| ● LOGO! |
No |
| ● WinAC |
Yes |
| ● SINUMERIK |
No |
| ● SIMOTION |
No |
| ● Allen Bradley (EtherNet/IP) |
No |
| ● Allen Bradley (DF1) |
No |
| ● Mitsubishi (MC TCP/IP) |
No |
| ● Mitsubishi (FX) |
No |
| ● OMRON (FINS TCP) |
No |
| ● OMRON (LINK/Multilink) |
No |
| ● Modicon (Modbus TCP/IP) |
No |
| ● Modicon (Modbus) |
No |
| Mechanics/material |
|
| Enclosure material (front) |
|
| ● Plastic |
No |
| ● Aluminum |
Yes |
| ● Stainless steel |
No |
| Service life |
|
| ● Short-stroke keys (in switching cycles) |
1 500 000 |
| ● LEDs (ON period) |
100 % |
| Dimensions |
|
| Width of the housing front |
240 mm |
| Height of housing front |
204 mm |
| Mounting cutout, width |
226 mm |
| Mounting cutout, height |
190 mm |
| Overall depth |
53 mm |
| Weights |
|
| Weight (without packaging) |
1 130 g |