SIEMENS 6AV6645-0CB01-0AX0
- EICHLER-art.no.: K0170453
- EAN: 4025515089797
- UPC: 040892692389
Product description
SIMATIC MOBILE PANEL 277 WITH INTEGRATED ACKNOWLEDGMENT BUTTON AND STOP PUSHBUTTON, CONFIGURABLE WITH WINCC FLEXIBLE STANDARD VERSION 2005 SP1 OR HIGHER OR TIA PORTAL V11 TO V14
Services for SIEMENS 6AV6645-0CB01-0AX0
SIEMENS |
6AV6645-0CB01-0AX0 –
additional product information
| Delivery information | |||
|---|---|---|---|
| Export identifier | AL: N ECCN: 5D992 | ||
| Net weight | 2.84 | ||
| Quantity | 1 Stück | ||
| Packaging quantity | 1 | ||
| Additional product information | |||
|---|---|---|---|
| Product status | EOP: 2021-10-01 | ||
| EAN | 4025515089797 | ||
| UPC | 040892692389 | ||
| Static lot number | 85371098 | ||
| List indicator | ST80.1F | ||
| Product group | 4245 | ||
| Country of origin | AT | ||
| Compliance with the substance restrictions according to RoHS directive | Since: 20130827 | ||
| Product classifications | Version | Classification | |
|---|---|---|---|
| eClass | 4 | 27-36-01-02 | |
| eClass | 5.1 | 27-24-23-03 | |
| eClass | 6.0 | 27-24-23-03 | |
| ETIM | 3 | / | |
| ETIM | 4 | EC001427 | |
| ETIM | 5 | EC001427 | |
What is 6AV6645-0CB01-0AX0 and where is it used?
The 6AV6645-0CB01-0AX0 is a SIMATIC Mobile Panel 277 from Siemens. This variant is designed for mobile operation and service tasks on machines and systems and features an integrated enabling switch and STOP button. As a result, it is particularly suitable for applications where operators work close to the machine, such as setup, commissioning, maintenance, troubleshooting or manual movements on production cells. The panel belongs to the 8-inch class of the Mobile Panel 277 family and, depending on the version, can be connected via suitable connection cables to DP or PN Connection Boxes. Engineering is carried out with WinCC flexible Standard; its use in TIA-based HMI environments is also documented within the product ecosystem.
Overview of the most important technical data and what it means
For technical classification, the following points are particularly important: The device features a 7.5" TFT colour display with 640 × 480 pixels and 65,536 colours. This makes it well suited for classic machine visualisation, diagnostic screens and parameterisable operating masks. The analogue resistive touchscreen is robust in industrial environments and can be operated more precisely with gloves or a stylus than many capacitive displays. In addition, 18 membrane keys with LEDs are available, simplifying fixed machine functions and acknowledgements. For spare-parts evaluation, further key features include a 520 MHz ARM processor, 6 MB usable application memory, up to 128 MB main memory, USB, RS422/RS485, Ethernet/PROFIBUS/PROFINET connectivity via the connection system, IP65 protection when connected, and a drop resistance of up to 1.2 m.
Product status, life-cycle status and obsolescence
For procurement and risk assessment, the product life cycle is crucial. The EICHLER product page lists the product status EOP with the date 01.10.2021 for the 6AV6645-0CB01-0AX0. In the current Siemens status documentation, the Mobile Panel 277 8" +ZT+ST variant is also listed with the milestone date 01.10.2021. Siemens announced the phase-out of the Mobile Panels 177/277 family as early as 2016 and generally recommends the Mobile Panels 2nd Generation family for new machines. However, a clearly verified 1:1 successor for this exact variant is not explicitly identified in the reviewed manufacturer documentation. An important point for purchasing departments is that Siemens notes that, for certain spare parts, the defective unit may need to be returned in order to maintain supply availability until the end of the spare-parts support phase.
Available EICHLER services and when they are relevant in practice
For operators of older Mobile Panels, it is not only the part number that matters but also the supply strategy after obsolescence. EICHLER currently offers repair, exchange, used equipment and new unit on request for this device. The product page specifies 1–3 days for repair, exchange and used units. According to the page, repair includes technical cleaning, preventive maintenance, comprehensive functional testing and a minimum 24-month warranty. For maintenance departments, this is relevant when the existing project, operating concept and mechanical integration should remain unchanged. For purchasing departments, an exchange unit or a tested used device can be the better option when downtime costs exceed the time required for internal diagnostics. For decision-makers, this combination of repair, exchange and spare-parts availability is essential to maintain operational reliability despite the product's end-of-life status.
| Attribute | Value |
|---|---|
| Product type designation | Mobile Panel 277 |
| Customer-specific configuration | Yes |
| Display | |
| Design of display | TFT |
| Screen diagonal | 7.5 in |
| Color display | Yes |
| Number of colors | 65 536 |
| Resolution (pixels) | |
| ● Horizontal image resolution | 640 pixel |
| ● Vertical image resolution | 480 pixel |
| Backlighting | |
| ● MTBF backlighting (at 25 °C) | 50 000 h |
| Control elements | |
| Control elements | Keys and touch |
| Keyboard fonts | |
| ● Membrane keyboard | |
| — user-definable label membrane keys | Yes |
| ● Function keys | |
| — Number of function keys | 18 |
| — Number of function keys with LEDs | 18 |
| ● Keys with LED | Yes |
| ● Numeric keyboard | Yes |
| ● alphanumeric keyboard | Yes |
| ● hexadecimal keyboard | Yes |
| ● Multi-key operation | Yes |
| — Number of multi-key operations | 2 |
| Touch operation | |
| ● Design as touch screen | Yes; analog, resistive |
| Connection type | |
| ● Type of connection for mouse/keyboard/barcode reader | USB / USB / USB |
| Special operator controls | |
| ● Stop button | Yes |
| ● Acknowledgement button | Yes |
| ● Key-operated switch | No |
| ● Illuminated pushbutton | No |
| ● Handwheel | No |
| Supply voltage | |
| Design of the power supply | via connection box |
| Type of supply voltage | DC |
| Processor | |
| Processor type | ARM, 520 MHz |
| Memory | |
| Type of memory | Flash / RAM |
| Memory available for user data | 6 Mbyte |
| Capacity of main memory, max. | 128 Mbyte |
| Accumulator | |
| Buffer battery | Yes; maximum buffer time 10 min |
| Time of day | |
| Clock | |
| ● Hardware clock (real-time) | Yes |
| ● retentive | Yes |
| ● synchronizable | Yes |
| Interfaces | |
| Interfaces/bus type | 1x RS 422, 1x RS 485, 1x Ethernet (RJ45) (max. 12 Mbit/s) |
| Number of industrial Ethernet interfaces | 1 |
| Number of RS 485 interfaces | 1 |
| Number of RS 422 interfaces | 1 |
| Number of USB interfaces | 1 |
| Number of wireless interfaces | 0 |
| Multimedia card/SD card slot | 1 MMC/SD card slot |
| Protocols | |
| Supports protocol for PROFINET IO | Yes |
| PROFIsafe | No |
| PROFIBUS | Yes |
| EtherNet/IP | Yes |
| AS-Interface | No |
| Protocols (Ethernet) | |
| ● TCP/IP | Yes |
| Further protocols | |
| ● MODBUS | Yes |
| ● other bus systems | Yes |
| Communication functions | |
| Wireless communication | |
| ● supported standards | |
| — Radio standard WLAN 802.11 | No |
| Standards, approvals, certificates | |
| Certificate of suitability | CE, cULus, C-TICK, SIBE |
| CE mark | Yes |
| cULus | Yes |
| RCM (formerly C-TICK) | Yes |
| Suitable for safety functions | Yes |
| Highest safety class achievable in safety mode | |
| ● Performance level according to ISO 13849-1 | d |
| Ambient conditions | |
| Free fall | |
| ● Fall height, max. | 1.2 m |
| Ambient temperature during operation | |
| ● min. | 0 °C |
| ● max. | 40 °C |
| Ambient temperature during storage/transportation | |
| ● min. | -20 °C |
| ● max. | 60 °C |
| Relative humidity | |
| ● Operation, max. | 80 % |
| Operating systems | |
| pre-installed operating system | Windows CE |
| Configuration | |
| Message indicator | Yes |
| Alarm system (incl. buffer and acknowledgment) | Yes |
| Process value display (output) | Yes |
| Process value default (input) possible | Yes |
| Recipe management | Yes |
| Configuration software | |
| ● Configuration tool | WinCC flexible Standard Version 2005 SP1 or higher (to be ordered separately) |
| ● WinCC flexible Compact | No |
| ● WinCC flexible Standard | Yes |
| ● WinCC flexible Advanced | Yes |
| ● WinCC Basic (TIA Portal) | No |
| ● WinCC Comfort (TIA Portal) | Yes |
| ● WinCC Advanced (TIA Portal) | Yes |
| ● WinCC Professional (TIA Portal) | Yes |
| Languages | |
| Online languages | |
| ● Number of online/runtime languages | 16 |
| Project languages | |
| ● Languages per project | 32 |
| Functionality under WinCC (TIA Portal) | |
| Libraries | Yes |
| Applications/options | Internet Explorer, Sm@rtService, Sm@rtAccess |
| ● Web browser | Yes |
| ● SIMATIC WinCC Sm@rtServer | Yes |
| ● Connection point identification | Yes |
| Number of Visual Basic Scripts | Yes |
| Task planner | Yes |
| Help system | Yes |
| ● Number of characters per info text | 70 |
| Message system | |
| ● Number of alarm classes | 32 |
| ● Bit messages | Yes |
| — Number of bit messages | 4 000 |
| ● Analog messages | Yes |
| — Number of analog messages | 4 000 |
| ● System messages HMI | Yes |
| ● System messages PLC | Yes |
| ● System event, more (SIMATIC S7, SINUMERIK, SIMOTION, ... ) | Yes |
| ● Lines | 1 |
| ● Number of characters per message | 80 |
| ● Number of process values per message | 8 |
| ● Acknowledgment groups | |
| — Number of acknowledgement groups | 99 |
| ● Message indicator | Yes |
| ● First/last value | Yes |
| Recipe management | |
| ● Number of recipes | 300 |
| ● Data records per recipe | 500 |
| ● Entries per data record | 1 000 |
| ● Recipe memory | 64 KB integrated Flash, expandable |
| Variables | |
| ● Number of variables per device | 2 048 |
| ● Number of variables per screen | 200 |
| ● Number of variables | 1 000 |
| ● Initial values | 2 048 |
| ● Type Date & Time | 2 048 |
| ● Limit values | Yes |
| ● Multiplexing | Yes |
| ● Structures | Yes |
| Images | |
| ● Number of configurable images | 500 |
| ● Permanent window/default | Yes |
| ● Start screen configurable | Yes |
| ● Image selection by PLC | Yes |
| ● Image number in the PLC | Yes |
| Image objects | |
| ● Text objects | 10 000 text elements |
| ● Number of I/O fields per image | 200 |
| ● Number of date/time fields | 200 |
| ● Return | Yes |
| ● Graphics object | Bit maps, icons, vector graphics |
| — Icons | 1 000 |
| Complex image objects | |
| ● Status/control | Yes; With SIMATIC S7 |
| ● dynamic objects | Diagrams, bar graphs, sliders, analog display, invisible buttons |
| — Number of objects per project | 1 000 |
| — Number of curve diagrams per image | 10 |
| ● Methods | Trend / profile |
| ● Bar graphs | |
| — Number of bars per chart | 10 |
| ● Sliders | |
| — Number of slides per image | 10 |
| ● Pointer instruments | |
| — Number of analog indicators per image | 10 |
| ● Limit value lines | Yes |
| ● Number of alphanumerical fields | 300 |
| — alphanumeric fields per image | 200 |
| ● Number of numerical fields | 2 048 |
| — numerical fields per image | 200 |
| ● Number of password fields | 2 048 |
| ● Number of visible switches per project | 200 |
| — visible switches per image | 200 |
| — hidden switches per image | 200 |
| ● Number of status switches per project | 200 |
| — Number of status switches per image | 200 |
| ● Number of selector switches per project | 200 |
| — Selector switches per image | 200 |
| ● Number of decade switches per project | 200 |
| — Decade switches per image | 200 |
| ● Number of signal lamps per project | 200 |
| — Signal lamps per image | 200 |
| Attributes for dynamic objects | |
| ● Color change | Yes |
| ● X/Y movement | Yes |
| ● Hide | Yes |
| Lists | |
| ● Number of text lists per project | 500 |
| ● Number of text lists per image | 200 |
| ● Number of entries per text list | 256 |
| ● Number of graphics lists per project | 400 |
| ● Number of graphic lists per image | 200 |
| ● Number of entries per graphics list | 256 |
| Archiving | |
| ● Number of archives per device | 20 |
| ● Number of measuring points per project | 20 |
| ● Number of entries per archive | 10 000 |
| ● Message archive | Yes |
| ● Process value archive | Yes |
| ● Archiving methods | |
| — Sequential archive | Yes |
| — Short-term archive | Yes |
| ● Memory location | MultiMediaCard |
| ● Data storage format | |
| — CSV | Yes |
| ● Online evaluation | |
| — using trend curves | Yes |
| Filters | |
| ● cyclic | Yes |
| ● Tolerance | Yes |
| ● Change | Yes |
| Security | |
| ● Number of user groups | 50 |
| ● Number of user rights | 32 |
| ● Password export/import | Yes |
| Logging through printer | |
| ● Recording/Printing | Alarms, report (shift report), color print, hardcopy |
| Transfer (upload/download) | |
| ● Transfer of configuration | MPI/PROFIBUS DP, USB, Ethernet, automatic transfer recognition |
| Process coupling | |
| ● Connection to controller | S5, S7-200, S7-300/400, TI 505, SINUMERIK, SIMOTION, Allen Bradley (DF1), Allen Bradley (DF485), Mitsubishi (FX), OMRON (LINK/Multilink), Modicon (Modbus), further non-Siemens drivers, see chapter "System interfaces" |
| ● S7-1200 | Yes |
| ● S7-1500 | Yes |
| ● S7-200 | Yes |
| — PPI (point-to-point) | Yes |
| — PPI network | Yes |
| — MPI | Yes |
| — PROFIBUS DP | Yes |
| — Ethernet | Yes |
| ● S7-300/400 | Yes |
| — MPI | Yes |
| — PROFIBUS DP | Yes |
| — PROFINET | Yes |
| ● SINUMERIK | Yes |
| ● SIMOTION | Yes |
| ● S5 | Yes |
| — serial | Yes |
| — PROFIBUS DP | Yes |
| ● TI 505 | Yes |
| ● Allen Bradley (DF1) | Yes |
| ● Allen Bradley (DF485) | Yes |
| ● Mitsubishi (FX) | Yes |
| ● Mitsubishi (MP4) | Yes |
| ● OMRON (LINK/Multilink) | Yes |
| ● Modicon (Modbus) | Yes |
| ● GE-Fanuc (SNP) | Yes |
| Functions | |
| ● TAB sequence | Yes |
| ● Calculating functions | Yes |
| ● Animate | Yes |
| Service tools/configuration aids | |
| ● Clean screen | Yes |
| ● Touch calibration | Yes |
| ● Backup/Restore manually | Yes |
| ● Simulation | Yes |
| ● Device switchover | Yes |
| ● Delta transfer | Yes |
| Peripherals/Options | |
| Peripherals | Printer, barcode reader |
| Printer | Yes |
| SIMATIC HMI MM memory card: Multi Media Card | Yes |
| SIMATIC HMI SD memory card: Secure Digital memory card | Yes |
| USB memory | Yes |
| Additional software components loadable | Yes |
| Mechanics/material | |
| Enclosure material (front) | plastic |
| Dimensions | |
| Enclosure diameter | 290 mm |
| Depth of housing | 103 mm |
| Weights | |
| Weight (without packaging) | 1.7 kg |
| Fault description | Possible solution |
|---|---|
| Why does the Mobile Panel 277 touchscreen respond inaccurately or not at all? | Open the touchscreen calibration on the operator panel and complete the calibration process using all displayed calibration crosses. After the last point, the touchscreen must be touched again within 30 seconds so that the new calibration is saved. If this confirmation is not performed in time, the previous calibration remains active. |
| Why does the Mobile Panel 277 no longer establish a connection after being moved to another Connection Box? | First check whether a backup battery is installed and functioning correctly. Siemens states that the optional battery can prevent a restart when switching between Connection Boxes and provides buffering for up to 10 minutes. Without sufficient buffering, a communication interruption may occur during reconnection. For DP installations, an additional practical point is important: the Box ID is often confused with the PROFIBUS address. In the SPS Forum, it is pointed out for Mobile Panel 277 devices that the docking station does not have its own PROFIBUS address; the relevant address is configured in the panel, while the switches on the box are used for the Box ID. |
| Why does the project transfer to the panel fail? | Check whether the operator panel is actually in Transfer mode, whether the correct data channel has been configured and whether the appropriate connection type and parameters have been selected in WinCC flexible. Siemens lists these requirements as prerequisites for a successful transfer. If the connection is unavailable or interrupted, the engineering PC reports an error. Siemens also refers in a dedicated FAQ to various solutions for download problems and states that common causes are related to communication, updates and project transfer. |
| Why does the panel no longer start after an interrupted operating system update and display “Image is corrupt”? | In this case, the device should be completely powered down and restarted while ProSave is prepared for the recovery procedure. In the SPS Forum, it is described that several attempts may sometimes be necessary and that using a simple switch between the PG and the panel can help if Windows network detection causes interference. Siemens additionally states for OS updates via bootstrapping that a lower bit rate should be selected in the event of connection errors and that a PC/PPI cable version 3 or higher is required for higher bit rates. |
| Why does WinCC flexible report that the operator panel type is invalid after project conversion? | This behaviour can occur with older Mobile Panel 277 projects when they are opened and upgraded in a later WinCC flexible environment. In the SPS Forum, a project originally created with SP3 is documented where, after opening it in SP5, only newer device types were available and the software reported the older Mobile Panel 277 8" IWLAN as invalid. In such cases, the migration strategy should be evaluated in advance rather than converting the project directly in a production environment. |
Is 6AV6645-0CB01-0AX0 still regularly available or already discontinued?
The device is no longer part of the regular product life cycle. EICHLER lists this part number with EOP status as of 01.10.2021. Siemens also includes this variant in its HMI status documentation with the corresponding milestone date of 01.10.2021 and had already announced the phase-out of the Mobile Panels 177/277 family on 25.04.2016. For new machines, Siemens refers users to the Mobile Panels 2nd Generation family. For existing installations, this means that procurement is still possible, but availability depends more heavily on spare-parts status, return requirements and available service options than is the case for active series products.
Which Connection Boxes and cables are relevant for the Mobile Panel 277?
The Mobile Panel 277 operates with dedicated connection cables. Siemens specifies a DP cable for the Connection Box DP and a PN cable for the Connection Box PN. For operators modernising existing installations, another important point is that Siemens states that Mobile Panels 2nd Generation Connection Boxes can also be used with predecessor devices such as 6AV6645-0CA01-0AX0, 6AV6645-0CB01-0AX0 and 6AV6645-0CC01-0AX0, although with certain limitations. These include the absence of PROFIsafe communication and unavailable signals such as "Mobile Panel connected" or "Control".
Which software can I use to configure or migrate 6AV6645-0CB01-0AX0?
For this device, WinCC flexible Standard from Version 2005 SP1 is the traditional engineering platform. On the EICHLER product page, the panel is also listed in the context of TIA Portal V11 to V14. Siemens documentation for WinCC in TIA Portal continues to reference the Mobile Panel 277 in compatibility and migration scenarios. In practice, this means that older projects should not be transferred to newer engineering versions without preparation. Siemens specifically highlights changes related to image transfer and signature verification around V14. Before migrating older WinCC flexible projects, the compatibility of the device type, HSP version and project version should always be verified.
When is repair more sensible than exchange or purchasing a used unit?
Repair is generally the better option when the existing device is already mechanically and electrically integrated into the machine, the project is to remain unchanged and the goal is to minimise engineering effort. An exchange unit is the faster solution when downtime is the primary concern. A tested used unit can be attractive when building a spare-parts inventory for legacy systems. EICHLER currently specifies 1–3 days for repair, exchange and used units for this part number. The repair service includes cleaning, preventive maintenance, functional testing and a minimum 24-month warranty. This is particularly relevant for operators who need to manage obsolescence without carrying out an immediate redesign.
Which features should always be checked during spare-parts evaluation?
Do not compare only the base part number 6AV6645-0CB01-0AX0; the functional variant should also be verified. This version includes an enabling switch and a STOP button, while a handwheel, illuminated pushbuttons and a key switch are not included. In addition, the following characteristics should be checked: 7.5-inch display, 640 × 480 pixels, 18 LED function keys, resistive touchscreen, 520 MHz ARM processor, 6 MB application memory, and the required connection method using the correct Connection Box/cable combination. These details determine whether a spare part is electrically, mechanically and functionally compatible with the existing machine.
How long does the panel remain operational when moving between Connection Boxes?
With the optional backup battery, the Mobile Panel can avoid a restart when switching between Connection Boxes. Siemens specifies a maximum buffering time of 10 minutes. During this period, the backlight is switched off, but the project can remain active. Siemens also notes that the same system alarms that occur during a communication interruption may be generated when reconnecting the panel. For service and maintenance personnel, this is important because, although switching between Connection Boxes is an intended function, the procedure should still be planned and diagnosed carefully.