SIEMENS 6AV6645-0CB01-0AX0

  • EICHLER-art.no.: K0170453
  • EAN: 4025515089797
  • UPC: 040892692389

Product description

SIMATIC MOBILE PANEL 277 WITH INTEGRATED ACKNOWLEDGMENT BUTTON AND STOP PUSHBUTTON, CONFIGURABLE WITH WINCC FLEXIBLE STANDARD VERSION 2005 SP1 OR HIGHER OR TIA PORTAL V11 TO V14

Services for SIEMENS 6AV6645-0CB01-0AX0

Repair

1-3 days

from 1.798,32 €

to 3.781,02 €

per pc. 159,00 €

Replacement

1-3 days

9 Pcs.

3.213,90 €

per pc. 159,00 €

3.213,90 € *

Please enter an offer recipient here.


Used

1-3 days

9 Pcs.

3.571,00 €

per pc. 159,00 €

3.571,00 € *

Please enter an offer recipient here.


New

Delivery information
Export identifier AL: N ECCN: 5D992
Net weight 2.84
Quantity 1 Stück
Packaging quantity 1
Additional product information
Product status EOP: 2021-10-01
EAN 4025515089797
UPC 040892692389
Static lot number 85371098
List indicator ST80.1F
Product group 4245
Country of origin AT
Compliance with the substance restrictions according to RoHS directive Since: 20130827
Product classifications Version Classification
eClass 4 27-36-01-02
eClass 5.1 27-24-23-03
eClass 6.0 27-24-23-03
ETIM 3 /
ETIM 4 EC001427
ETIM 5 EC001427

What is 6AV6645-0CB01-0AX0 and where is it used?

The 6AV6645-0CB01-0AX0 is a SIMATIC Mobile Panel 277 from Siemens. This variant is designed for mobile operation and service tasks on machines and systems and features an integrated enabling switch and STOP button. As a result, it is particularly suitable for applications where operators work close to the machine, such as setup, commissioning, maintenance, troubleshooting or manual movements on production cells. The panel belongs to the 8-inch class of the Mobile Panel 277 family and, depending on the version, can be connected via suitable connection cables to DP or PN Connection Boxes. Engineering is carried out with WinCC flexible Standard; its use in TIA-based HMI environments is also documented within the product ecosystem.

Overview of the most important technical data and what it means

For technical classification, the following points are particularly important: The device features a 7.5" TFT colour display with 640 × 480 pixels and 65,536 colours. This makes it well suited for classic machine visualisation, diagnostic screens and parameterisable operating masks. The analogue resistive touchscreen is robust in industrial environments and can be operated more precisely with gloves or a stylus than many capacitive displays. In addition, 18 membrane keys with LEDs are available, simplifying fixed machine functions and acknowledgements. For spare-parts evaluation, further key features include a 520 MHz ARM processor, 6 MB usable application memory, up to 128 MB main memory, USB, RS422/RS485, Ethernet/PROFIBUS/PROFINET connectivity via the connection system, IP65 protection when connected, and a drop resistance of up to 1.2 m.

Product status, life-cycle status and obsolescence

For procurement and risk assessment, the product life cycle is crucial. The EICHLER product page lists the product status EOP with the date 01.10.2021 for the 6AV6645-0CB01-0AX0. In the current Siemens status documentation, the Mobile Panel 277 8" +ZT+ST variant is also listed with the milestone date 01.10.2021. Siemens announced the phase-out of the Mobile Panels 177/277 family as early as 2016 and generally recommends the Mobile Panels 2nd Generation family for new machines. However, a clearly verified 1:1 successor for this exact variant is not explicitly identified in the reviewed manufacturer documentation. An important point for purchasing departments is that Siemens notes that, for certain spare parts, the defective unit may need to be returned in order to maintain supply availability until the end of the spare-parts support phase.

Available EICHLER services and when they are relevant in practice

For operators of older Mobile Panels, it is not only the part number that matters but also the supply strategy after obsolescence. EICHLER currently offers repair, exchange, used equipment and new unit on request for this device. The product page specifies 1–3 days for repair, exchange and used units. According to the page, repair includes technical cleaning, preventive maintenance, comprehensive functional testing and a minimum 24-month warranty. For maintenance departments, this is relevant when the existing project, operating concept and mechanical integration should remain unchanged. For purchasing departments, an exchange unit or a tested used device can be the better option when downtime costs exceed the time required for internal diagnostics. For decision-makers, this combination of repair, exchange and spare-parts availability is essential to maintain operational reliability despite the product's end-of-life status.

Attribute Value
Product type designation Mobile Panel 277
Customer-specific configuration Yes
Display
Design of display TFT
Screen diagonal 7.5 in
Color display Yes
Number of colors 65 536
Resolution (pixels)
● Horizontal image resolution 640 pixel
● Vertical image resolution 480 pixel
Backlighting
● MTBF backlighting (at 25 °C) 50 000 h
Control elements
Control elements Keys and touch
Keyboard fonts
● Membrane keyboard
— user-definable label membrane keys Yes
● Function keys
— Number of function keys 18
— Number of function keys with LEDs 18
● Keys with LED Yes
● Numeric keyboard Yes
● alphanumeric keyboard Yes
● hexadecimal keyboard Yes
● Multi-key operation Yes
— Number of multi-key operations 2
Touch operation
● Design as touch screen Yes; analog, resistive
Connection type
● Type of connection for mouse/keyboard/barcode reader USB / USB / USB
Special operator controls
● Stop button Yes
● Acknowledgement button Yes
● Key-operated switch No
● Illuminated pushbutton No
● Handwheel No
Supply voltage
Design of the power supply via connection box
Type of supply voltage DC
Processor
Processor type ARM, 520 MHz
Memory
Type of memory Flash / RAM
Memory available for user data 6 Mbyte
Capacity of main memory, max. 128 Mbyte
Accumulator
Buffer battery Yes; maximum buffer time 10 min
Time of day
Clock
● Hardware clock (real-time) Yes
● retentive Yes
● synchronizable Yes
Interfaces
Interfaces/bus type 1x RS 422, 1x RS 485, 1x Ethernet (RJ45) (max. 12 Mbit/s)
Number of industrial Ethernet interfaces 1
Number of RS 485 interfaces 1
Number of RS 422 interfaces 1
Number of USB interfaces 1
Number of wireless interfaces 0
Multimedia card/SD card slot 1 MMC/SD card slot
Protocols
Supports protocol for PROFINET IO Yes
PROFIsafe No
PROFIBUS Yes
EtherNet/IP Yes
AS-Interface No
Protocols (Ethernet)
● TCP/IP Yes
Further protocols
● MODBUS Yes
● other bus systems Yes
Communication functions
Wireless communication
● supported standards
— Radio standard WLAN 802.11 No
Standards, approvals, certificates
Certificate of suitability CE, cULus, C-TICK, SIBE
CE mark Yes
cULus Yes
RCM (formerly C-TICK) Yes
Suitable for safety functions Yes
Highest safety class achievable in safety mode
● Performance level according to ISO 13849-1 d
Ambient conditions
Free fall
● Fall height, max. 1.2 m
Ambient temperature during operation
● min. 0 °C
● max. 40 °C
Ambient temperature during storage/transportation
● min. -20 °C
● max. 60 °C
Relative humidity
● Operation, max. 80 %
Operating systems
pre-installed operating system Windows CE
Configuration
Message indicator Yes
Alarm system (incl. buffer and acknowledgment) Yes
Process value display (output) Yes
Process value default (input) possible Yes
Recipe management Yes
Configuration software
● Configuration tool WinCC flexible Standard Version 2005 SP1 or higher (to be ordered separately)
● WinCC flexible Compact No
● WinCC flexible Standard Yes
● WinCC flexible Advanced Yes
● WinCC Basic (TIA Portal) No
● WinCC Comfort (TIA Portal) Yes
● WinCC Advanced (TIA Portal) Yes
● WinCC Professional (TIA Portal) Yes
Languages
Online languages
● Number of online/runtime languages 16
Project languages
● Languages per project 32
Functionality under WinCC (TIA Portal)
Libraries Yes
Applications/options Internet Explorer, Sm@rtService, Sm@rtAccess
● Web browser Yes
● SIMATIC WinCC Sm@rtServer Yes
● Connection point identification Yes
Number of Visual Basic Scripts Yes
Task planner Yes
Help system Yes
● Number of characters per info text 70
Message system
● Number of alarm classes 32
● Bit messages Yes
— Number of bit messages 4 000
● Analog messages Yes
— Number of analog messages 4 000
● System messages HMI Yes
● System messages PLC Yes
● System event, more (SIMATIC S7, SINUMERIK, SIMOTION, ... ) Yes
● Lines 1
● Number of characters per message 80
● Number of process values per message 8
● Acknowledgment groups
— Number of acknowledgement groups 99
● Message indicator Yes
● First/last value Yes
Recipe management
● Number of recipes 300
● Data records per recipe 500
● Entries per data record 1 000
● Recipe memory 64 KB integrated Flash, expandable
Variables
● Number of variables per device 2 048
● Number of variables per screen 200
● Number of variables 1 000
● Initial values 2 048
● Type Date & Time 2 048
● Limit values Yes
● Multiplexing Yes
● Structures Yes
Images
● Number of configurable images 500
● Permanent window/default Yes
● Start screen configurable Yes
● Image selection by PLC Yes
● Image number in the PLC Yes
Image objects
● Text objects 10 000 text elements
● Number of I/O fields per image 200
● Number of date/time fields 200
● Return Yes
● Graphics object Bit maps, icons, vector graphics
— Icons 1 000
Complex image objects
● Status/control Yes; With SIMATIC S7
● dynamic objects Diagrams, bar graphs, sliders, analog display, invisible buttons
— Number of objects per project 1 000
— Number of curve diagrams per image 10
● Methods Trend / profile
● Bar graphs
— Number of bars per chart 10
● Sliders
— Number of slides per image 10
● Pointer instruments
— Number of analog indicators per image 10
● Limit value lines Yes
● Number of alphanumerical fields 300
— alphanumeric fields per image 200
● Number of numerical fields 2 048
— numerical fields per image 200
● Number of password fields 2 048
● Number of visible switches per project 200
— visible switches per image 200
— hidden switches per image 200
● Number of status switches per project 200
— Number of status switches per image 200
● Number of selector switches per project 200
— Selector switches per image 200
● Number of decade switches per project 200
— Decade switches per image 200
● Number of signal lamps per project 200
— Signal lamps per image 200
Attributes for dynamic objects
● Color change Yes
● X/Y movement Yes
● Hide Yes
Lists
● Number of text lists per project 500
● Number of text lists per image 200
● Number of entries per text list 256
● Number of graphics lists per project 400
● Number of graphic lists per image 200
● Number of entries per graphics list 256
Archiving
● Number of archives per device 20
● Number of measuring points per project 20
● Number of entries per archive 10 000
● Message archive Yes
● Process value archive Yes
● Archiving methods
— Sequential archive Yes
— Short-term archive Yes
● Memory location MultiMediaCard
● Data storage format
— CSV Yes
● Online evaluation
— using trend curves Yes
Filters
● cyclic Yes
● Tolerance Yes
● Change Yes
Security
● Number of user groups 50
● Number of user rights 32
● Password export/import Yes
Logging through printer
● Recording/Printing Alarms, report (shift report), color print, hardcopy
Transfer (upload/download)
● Transfer of configuration MPI/PROFIBUS DP, USB, Ethernet, automatic transfer recognition
Process coupling
● Connection to controller S5, S7-200, S7-300/400, TI 505, SINUMERIK, SIMOTION, Allen Bradley (DF1), Allen Bradley (DF485), Mitsubishi (FX), OMRON (LINK/Multilink), Modicon (Modbus), further non-Siemens drivers, see chapter "System interfaces"
● S7-1200 Yes
● S7-1500 Yes
● S7-200 Yes
— PPI (point-to-point) Yes
— PPI network Yes
— MPI Yes
— PROFIBUS DP Yes
— Ethernet Yes
● S7-300/400 Yes
— MPI Yes
— PROFIBUS DP Yes
— PROFINET Yes
● SINUMERIK Yes
● SIMOTION Yes
● S5 Yes
— serial Yes
— PROFIBUS DP Yes
● TI 505 Yes
● Allen Bradley (DF1) Yes
● Allen Bradley (DF485) Yes
● Mitsubishi (FX) Yes
● Mitsubishi (MP4) Yes
● OMRON (LINK/Multilink) Yes
● Modicon (Modbus) Yes
● GE-Fanuc (SNP) Yes
Functions
● TAB sequence Yes
● Calculating functions Yes
● Animate Yes
Service tools/configuration aids
● Clean screen Yes
● Touch calibration Yes
● Backup/Restore manually Yes
● Simulation Yes
● Device switchover Yes
● Delta transfer Yes
Peripherals/Options
Peripherals Printer, barcode reader
Printer Yes
SIMATIC HMI MM memory card: Multi Media Card Yes
SIMATIC HMI SD memory card: Secure Digital memory card Yes
USB memory Yes
Additional software components loadable Yes
Mechanics/material
Enclosure material (front) plastic
Dimensions
Enclosure diameter 290 mm
Depth of housing 103 mm
Weights
Weight (without packaging) 1.7 kg

Fault description Possible solution
Why does the Mobile Panel 277 touchscreen respond inaccurately or not at all? Open the touchscreen calibration on the operator panel and complete the calibration process using all displayed calibration crosses. After the last point, the touchscreen must be touched again within 30 seconds so that the new calibration is saved. If this confirmation is not performed in time, the previous calibration remains active.
Why does the Mobile Panel 277 no longer establish a connection after being moved to another Connection Box? First check whether a backup battery is installed and functioning correctly. Siemens states that the optional battery can prevent a restart when switching between Connection Boxes and provides buffering for up to 10 minutes. Without sufficient buffering, a communication interruption may occur during reconnection. For DP installations, an additional practical point is important: the Box ID is often confused with the PROFIBUS address. In the SPS Forum, it is pointed out for Mobile Panel 277 devices that the docking station does not have its own PROFIBUS address; the relevant address is configured in the panel, while the switches on the box are used for the Box ID.
Why does the project transfer to the panel fail? Check whether the operator panel is actually in Transfer mode, whether the correct data channel has been configured and whether the appropriate connection type and parameters have been selected in WinCC flexible. Siemens lists these requirements as prerequisites for a successful transfer. If the connection is unavailable or interrupted, the engineering PC reports an error. Siemens also refers in a dedicated FAQ to various solutions for download problems and states that common causes are related to communication, updates and project transfer.
Why does the panel no longer start after an interrupted operating system update and display “Image is corrupt”? In this case, the device should be completely powered down and restarted while ProSave is prepared for the recovery procedure. In the SPS Forum, it is described that several attempts may sometimes be necessary and that using a simple switch between the PG and the panel can help if Windows network detection causes interference. Siemens additionally states for OS updates via bootstrapping that a lower bit rate should be selected in the event of connection errors and that a PC/PPI cable version 3 or higher is required for higher bit rates.
Why does WinCC flexible report that the operator panel type is invalid after project conversion? This behaviour can occur with older Mobile Panel 277 projects when they are opened and upgraded in a later WinCC flexible environment. In the SPS Forum, a project originally created with SP3 is documented where, after opening it in SP5, only newer device types were available and the software reported the older Mobile Panel 277 8" IWLAN as invalid. In such cases, the migration strategy should be evaluated in advance rather than converting the project directly in a production environment.

Is 6AV6645-0CB01-0AX0 still regularly available or already discontinued?

The device is no longer part of the regular product life cycle. EICHLER lists this part number with EOP status as of 01.10.2021. Siemens also includes this variant in its HMI status documentation with the corresponding milestone date of 01.10.2021 and had already announced the phase-out of the Mobile Panels 177/277 family on 25.04.2016. For new machines, Siemens refers users to the Mobile Panels 2nd Generation family. For existing installations, this means that procurement is still possible, but availability depends more heavily on spare-parts status, return requirements and available service options than is the case for active series products.

Which Connection Boxes and cables are relevant for the Mobile Panel 277?

The Mobile Panel 277 operates with dedicated connection cables. Siemens specifies a DP cable for the Connection Box DP and a PN cable for the Connection Box PN. For operators modernising existing installations, another important point is that Siemens states that Mobile Panels 2nd Generation Connection Boxes can also be used with predecessor devices such as 6AV6645-0CA01-0AX0, 6AV6645-0CB01-0AX0 and 6AV6645-0CC01-0AX0, although with certain limitations. These include the absence of PROFIsafe communication and unavailable signals such as "Mobile Panel connected" or "Control".

Which software can I use to configure or migrate 6AV6645-0CB01-0AX0?

For this device, WinCC flexible Standard from Version 2005 SP1 is the traditional engineering platform. On the EICHLER product page, the panel is also listed in the context of TIA Portal V11 to V14. Siemens documentation for WinCC in TIA Portal continues to reference the Mobile Panel 277 in compatibility and migration scenarios. In practice, this means that older projects should not be transferred to newer engineering versions without preparation. Siemens specifically highlights changes related to image transfer and signature verification around V14. Before migrating older WinCC flexible projects, the compatibility of the device type, HSP version and project version should always be verified.

When is repair more sensible than exchange or purchasing a used unit?

Repair is generally the better option when the existing device is already mechanically and electrically integrated into the machine, the project is to remain unchanged and the goal is to minimise engineering effort. An exchange unit is the faster solution when downtime is the primary concern. A tested used unit can be attractive when building a spare-parts inventory for legacy systems. EICHLER currently specifies 1–3 days for repair, exchange and used units for this part number. The repair service includes cleaning, preventive maintenance, functional testing and a minimum 24-month warranty. This is particularly relevant for operators who need to manage obsolescence without carrying out an immediate redesign.

Which features should always be checked during spare-parts evaluation?

Do not compare only the base part number 6AV6645-0CB01-0AX0; the functional variant should also be verified. This version includes an enabling switch and a STOP button, while a handwheel, illuminated pushbuttons and a key switch are not included. In addition, the following characteristics should be checked: 7.5-inch display, 640 × 480 pixels, 18 LED function keys, resistive touchscreen, 520 MHz ARM processor, 6 MB application memory, and the required connection method using the correct Connection Box/cable combination. These details determine whether a spare part is electrically, mechanically and functionally compatible with the existing machine.

How long does the panel remain operational when moving between Connection Boxes?

With the optional backup battery, the Mobile Panel can avoid a restart when switching between Connection Boxes. Siemens specifies a maximum buffering time of 10 minutes. During this period, the backlight is switched off, but the project can remain active. Siemens also notes that the same system alarms that occur during a communication interruption may be generated when reconnecting the panel. For service and maintenance personnel, this is important because, although switching between Connection Boxes is an intended function, the procedure should still be planned and diagnosed carefully.

Important documents

Repair accompanying note

Download the repair accompanying note as a PDF, or use the digital repair registration and send your defective modules to the EICHLER Service Centre for repair.

Laughing Eichler technician points to green PDF with special sale of automation technology

Your shopping basket

Loading shopping basket