SIEMENS 6AV6645-0AC01-0AX0
- EICHLER-art.no.: K0170448
- EAN: 4025515089971
- UPC: 662643029697
Product description
SIMATIC MOBILE PANEL 177 DP WITH INTEGRATED ACKNOWLEDGMENT BUTTON, STOP PUSHBUTTON, HANDWHEEL, KEYSWITCH AND ILLUMINATED PUSH-BUTTON, CONFIGURABLE WITH WINCC FLEXIBLE COMPACT VERSION 2005 OR HIGHER OR TIA PORTAL V11 TO V14
Services for SIEMENS 6AV6645-0AC01-0AX0
SIEMENS |
6AV6645-0AC01-0AX0 –
additional product information
| Delivery information | |||
|---|---|---|---|
| Export identifier | AL: N ECCN: 5D992 | ||
| Net weight | 1.674 | ||
| Quantity | 1 Stück | ||
| Packaging quantity | 1 | ||
| Additional product information | |||
|---|---|---|---|
| Product status | EOP: 2021-10-01 | ||
| EAN | 4025515089971 | ||
| UPC | 662643029697 | ||
| Static lot number | 85371098 | ||
| List indicator | ST9.80 | ||
| Product group | 4367 | ||
| Country of origin | AT | ||
| Compliance with the substance restrictions according to RoHS directive | Since: 20100101 | ||
| Product classifications | Version | Classification | |
|---|---|---|---|
| eClass | 4 | 27-36-01-02 | |
| eClass | 5.1 | 27-24-23-03 | |
| eClass | 6.0 | 27-24-23-03 | |
| ETIM | 3 | / | |
| ETIM | 4 | EC001427 | |
| ETIM | 5 | EC001427 | |
What is 6AV6645-0AC01-0AX0 and where is it used?
The 6AV6645-0AC01-0AX0 is a SIEMENS SIMATIC Mobile Panel 177 DP, designed for mobile machine operation and monitoring in industrial environments. It combines resistive touch control, a membrane keypad, and integrated operating elements such as an enabling switch, STOP button, handwheel, key switch, and illuminated pushbuttons.
This makes it particularly suitable for applications where operators need to work directly at the machine, for example during setup, maintenance, service work, or manual operation. According to Siemens documentation, the panel can be engineered with WinCC flexible Compact (from version 2005) and in TIA Portal V11 to V14. Because it is DP-oriented, it fits best into established SIMATIC environments and retrofit systems with existing PROFIBUS-based structures.
Overview of key technical data and what it means
The Mobile Panel features a 5.7-inch STN colour display with 320 × 240 pixels and 256 colours. For industrial use, it includes 14 function keys (8 of them with LEDs) and a resistive analogue touchscreen, designed for robust operation in demanding environments.
Communication is based on RS422 and RS485 (up to 12 Mbit/s) with PROFIBUS support, while Industrial Ethernet and USB are not available. This clearly indicates that the device is intended for classic serial and DP-based automation architectures.
It runs on Windows CE with a 200 MHz 32-bit RISC processor, and is specified for an operating temperature range of 0 to 40 °C. The safety-related design supports up to Performance Level d, which makes it suitable for machine-level safety-oriented operating concepts.
Product status, life cycle status and obsolescence
According to EICHLER data, this specific MLFB has an EOP (End of Production) status as of 01.10.2021. In addition, Siemens announced the end of availability for the Mobile Panel 177/277 family and associated connection boxes as of 01.10.2016.
For procurement, maintenance, and production planning, this means the risk related to failure, spare parts availability, and stocking strategy is significantly higher than for current HMI platforms.
Importantly, Siemens does not define a direct migration path to a KTP Mobile series for this exact device. Therefore, there is no officially verified 1:1 successor from the manufacturer. In practice, this shifts focus toward repair, exchange units, and strategic spare parts stocking.
Available EICHLER services and when they are relevant
For the 6AV6645-0AC01-0AX0, EICHLER offers repair, exchange, used units, and new units on request, along with optional test reports.
Repair is particularly suitable when the existing device should continue operating with the same project configuration and established operator logic. According to the service description, it includes technical cleaning, preventive maintenance, full functional testing, and at least a 24-month warranty.
An exchange unit is the best option in cases of urgent downtime, when a tested replacement is needed quickly. Used devices support cost-efficient operation of older systems or help build spare parts inventories. As of the reference date 23.04.2026, repair, exchange, and used units were typically available within 1–3 days, aimed at industrial customers.
| Attribute | Value |
|---|---|
| Product type designation | Mobile Panel 177 DP |
| Display | |
| Design of display | STN |
| Screen diagonal | 5.7 in |
| Color display | Yes |
| Number of colors | 256 |
| Resolution (pixels) | |
| ● Horizontal image resolution | 320 pixel |
| ● Vertical image resolution | 240 pixel |
| Backlighting | |
| ● MTBF backlighting (at 25 °C) | 50 000 h |
| ● Backlight dimmable | No |
| Control elements | |
| Control elements | Keys and touch |
| Keyboard fonts | |
| ● Membrane keyboard | |
| — user-definable label membrane keys | Yes |
| ● Function keys | |
| — Number of function keys | 14 |
| — Number of function keys with LEDs | 8 |
| ● Keys with LED | Yes; 8 with LED |
| ● Numeric keyboard | Yes |
| ● alphanumeric keyboard | Yes |
| ● hexadecimal keyboard | Yes |
| ● Multi-key operation | Yes |
| — Number of multi-key operations | 2 |
| Touch operation | |
| ● Design as touch screen | Yes; analog, resistive |
| Special operator controls | |
| ● Stop button | Yes |
| ● Acknowledgement button | Yes |
| ● Key-operated switch | Yes |
| ● Illuminated pushbutton | Yes |
| ● Handwheel | Yes |
| Supply voltage | |
| Design of the power supply | via connection box |
| Type of supply voltage | DC |
| Processor | |
| Processor type | RISC 32 bit, 200 MHz |
| Memory | |
| Type of memory | Flash / RAM |
| Memory available for user data | 2 048 kbyte |
| Accumulator | |
| Buffer battery | Yes; maximum buffer time 10 min |
| Type of output | |
| Info LED | No |
| Power LED | No |
| Error LED | No |
| Interfaces | |
| Interfaces/bus type | 1x RS 422,1x RS 485 (max. 12 Mbit/s) |
| Number of industrial Ethernet interfaces | 0 |
| Number of RS 485 interfaces | 1 |
| Number of RS 422 interfaces | 1 |
| Number of USB interfaces | 0 |
| Number of wireless interfaces | 0 |
| PC card slot | No |
| CF card slot | No |
| Multimedia card/SD card slot | combined |
| Protocols | |
| Supports protocol for PROFINET IO | No |
| PROFIsafe | No |
| PROFIBUS | Yes |
| EtherNet/IP | No |
| AS-Interface | No |
| Protocols (Ethernet) | |
| ● TCP/IP | No |
| Further protocols | |
| ● MODBUS | Yes |
| ● other bus systems | Yes |
| Communication functions | |
| Wireless communication | |
| ● supported standards | |
| — Radio standard WLAN 802.11 | No |
| Standards, approvals, certificates | |
| Certificate of suitability | CE, cULus, C-TICK, SIBE |
| CE mark | Yes |
| cULus | Yes |
| RCM (formerly C-TICK) | Yes |
| Suitable for safety functions | Yes |
| Highest safety class achievable in safety mode | |
| ● Performance level according to ISO 13849-1 | d |
| Use in hazardous areas | |
| ● cULus Class I Zone 2, Division 2 | No |
| ● FM Class I Division 2 | No |
| Ambient conditions | |
| Free fall | |
| ● Fall height, max. | 1.5 m |
| Ambient temperature during operation | |
| ● min. | 0 °C |
| ● max. | 40 °C |
| Ambient temperature during storage/transportation | |
| ● min. | -20 °C |
| ● max. | 60 °C |
| Relative humidity | |
| ● Operation, max. | 80 % |
| Operating systems | |
| pre-installed operating system | Windows CE |
| Configuration | |
| Message indicator | Yes |
| Alarm system (incl. buffer and acknowledgment) | Yes |
| Process value display (output) | Yes |
| Process value default (input) possible | Yes |
| Recipe management | Yes |
| Configuration software | |
| ● Configuration tool | WinCC flexible Compact Version 2005 or higher (to be ordered separately) |
| ● WinCC flexible Compact | Yes |
| ● WinCC flexible Standard | Yes |
| ● WinCC flexible Advanced | Yes |
| ● WinCC Basic (TIA Portal) | No |
| ● WinCC Comfort (TIA Portal) | Yes |
| ● WinCC Advanced (TIA Portal) | Yes |
| ● WinCC Professional (TIA Portal) | Yes |
| Languages | |
| Online languages | |
| ● Number of online/runtime languages | 5 |
| Project languages | |
| ● Languages per project | 32 |
| Functionality under WinCC (TIA Portal) | |
| Libraries | Yes |
| Applications/options | none |
| ● Web browser | No |
| ● Pocket Word | No |
| ● Pocket Excel | No |
| ● PDF Viewer | No |
| ● Media Player | No |
| ● SIMATIC WinCC Sm@rtServer | Yes |
| ● SIMATIC WinCC Audit | No |
| ● Connection point identification | Yes |
| Number of Visual Basic Scripts | No |
| ● Debugging in the simulator | No |
| Task planner | Yes |
| Help system | Yes |
| ● Number of characters per info text | 70 |
| Message system | |
| ● Number of alarm classes | 32 |
| ● Bit messages | Yes |
| — Number of bit messages | 2 000 |
| ● Analog messages | Yes |
| — Number of analog messages | 50 |
| ● Telegram message procedure Alarm S | No |
| ● System messages HMI | Yes |
| ● System messages PLC | No |
| ● System event, more (SIMATIC S7, SINUMERIK, SIMOTION, ... ) | No |
| ● Lines | 1 |
| ● Number of characters per message | 80 |
| ● Number of process values per message | 8 |
| ● Message indicator | Yes |
| ● acoustic feedback | No |
| ● First/last value | Yes |
| Recipe management | |
| ● Number of recipes | 100 |
| ● Data records per recipe | 200 |
| ● Entries per data record | 200 |
| ● Recipe memory | 32 KB integrated Flash, expandable |
| Variables | |
| ● Number of variables per device | 1 024 |
| ● Number of variables per screen | 50 |
| ● Limit values | Yes |
| ● Multiplexing | Yes |
| ● Structures | Yes |
| Images | |
| ● Number of configurable images | 500 |
| ● Permanent window/default | Yes |
| ● Start screen configurable | Yes |
| ● Image selection by PLC | Yes |
| ● Image number in the PLC | Yes |
| Image objects | |
| ● Text objects | 2 500 text elements |
| ● Number of I/O fields per image | 50 |
| ● Index of screen context | No |
| ● Return | Yes |
| ● Graphics object | Bit maps, vector graphics |
| Complex image objects | |
| ● Status/control | Yes; With SIMATIC S7 |
| ● dynamic objects | Diagrams, bar graphs, sliders, invisible buttons |
| ● Methods | Trend / profile |
| ● Bar graphs | |
| — Number of bars per chart | 5 |
| ● Limit value lines | Yes |
| ● Number of visible switches per project | 1 000 |
| Attributes for dynamic objects | |
| ● Color change | Yes |
| ● X/Y movement | Yes |
| ● Hide | Yes |
| ● Angle of rotation | No |
| Lists | |
| ● Number of text lists per project | 300 |
| ● Number of entries per text list | 30 |
| ● Number of graphics lists per project | 100 |
| Archiving | |
| ● Number of archives per device | 0 |
| ● Message archive | No |
| ● Process value archive | No |
| ● Archiving methods | |
| — Sequential archive | No |
| — Short-term archive | No |
| ● Memory location | |
| — USB memory | No |
| — Ethernet | No |
| ● Data storage format | |
| — CSV | No |
| — TXT | No |
| ● Online evaluation | |
| — using trend curves | No |
| Security | |
| ● Number of user groups | 50 |
| ● Number of user rights | 32 |
| ● Password export/import | Yes |
| Transfer (upload/download) | |
| ● Transfer of configuration | MPI/PROFIBUS DP, serial, automatic transfer recognition |
| Process coupling | |
| ● Connection to controller | S5, S7-200, S7-300/400, TI 505, Win AC, SINUMERIK, SIMOTION, Allen Bradley (DF1), Allen Bradley (DF485), Mitsubishi (FX), OMRON (LINK/Multilink), Modicon (Modbus), further non-Siemens drivers, see chapter "System interfaces" |
| ● S7-1200 | Yes; with restrictions |
| ● S7-1500 | Yes; with restrictions |
| ● S7-200 | Yes |
| — PPI (point-to-point) | Yes |
| — PPI network | Yes |
| — MPI | Yes |
| — PROFIBUS DP | Yes |
| ● S7-300/400 | Yes |
| — MPI | Yes |
| — PROFIBUS DP | Yes |
| — PROFINET | No |
| ● LOGO! | No |
| ● WinAC | Yes |
| ● SINUMERIK | Yes |
| ● SIMOTION | Yes |
| ● S5 | Yes |
| — serial | No |
| — PROFIBUS DP | Yes |
| ● TI 505 | Yes |
| ● Allen Bradley (EtherNet/IP) | No |
| ● Allen Bradley (DF1) | Yes |
| ● Allen Bradley (DF485) | Yes |
| ● Mitsubishi (MC TCP/IP) | No |
| ● Mitsubishi (FX) | Yes |
| ● Mitsubishi (MP4) | Yes |
| ● Telemecanique (ADJUST) | No |
| ● Telemecanique (Uni-Telway) | Yes |
| ● OMRON (FINS TCP) | No |
| ● OMRON (LINK/Multilink) | Yes |
| ● Modicon (Modbus TCP/IP) | No |
| ● Modicon (Modbus) | Yes |
| ● GE-Fanuc (SNP) | Yes |
| Functions | |
| ● Key repeat | No |
| ● TAB sequence | Yes |
| ● Calculating functions | Yes |
| ● Animate | Yes |
| ● Menu tree editor | No |
| ● Unit switchover | No |
| Service tools/configuration aids | |
| ● Clean screen | No |
| ● Touch calibration | Yes |
| ● Backup/Restore manually | Yes |
| ● Simulation | Yes |
| ● Device switchover | Yes |
| ● Delta transfer | Yes |
| ● Monitoring function for battery and memory | Yes |
| ● Trace (operation archive) | No |
| Expandability/openness | |
| ● Open Platform Program | Yes |
| Peripherals/Options | |
| Printer | Yes |
| SIMATIC HMI MM memory card: Multi Media Card | Yes |
| SIMATIC HMI SD memory card: Secure Digital memory card | No |
| USB memory | No |
| Mechanics/material | |
| Enclosure material (front) | plastic |
| Dimensions | |
| Enclosure diameter | 245 mm |
| Depth of housing | 58 mm |
| Weights | |
| Weight (without packaging) | 1.3 kg |
| Fault description | Possible solution |
|---|---|
| Why can I not establish a connection or transfer to the Mobile Panel 177 DP? | During transfer, at least one data channel must be enabled on the operator device. Siemens describes the direct connection via RS485 as the serial transfer path. In SPS-Forum discussions, instead of a USB/MPI adapter, a suitable PPI cable or compatible direct adapter is recommended for the Mobile Panel 177 DP. In addition, check whether the correct transfer channel is enabled, whether the panel is switched into transfer mode, and whether the current MPI/PROFIBUS-DP settings match the project configuration. |
| Why does the touchscreen respond inaccurately or hit the wrong position? | Siemens attributes this partly to parallax caused by installation position and viewing angle. In such cases, the touchscreen should be recalibrated via the Control Panel using the Recalibrate function, and the calibration should be saved. For long-term reliability, the screen should only be operated with a finger or a suitable touch stylus. Hard objects can damage the surface and increase misalignment issues. |
| Why does the STOP or emergency stop circuit trigger when unplugging or after a drop? | Siemens explicitly classifies this behaviour as safety-relevant depending on the connection box and device variant. When the Mobile Panel is connected, the STOP button can be integrated into the safety circuit. Disconnecting the cable or dropping the device may therefore trigger a machine stop. The connection box type, wiring of the safety circuit, STOP button state, and plug-in behaviour must therefore be checked against the machine’s safety logic. |
| Why does the box ID or docking point detection not work correctly? | Siemens requires a unique box ID for each connection box, set via rotary coding switches. This must be correctly configured in WinCC flexible using the corresponding variables for internal box ID, auxiliary variable, and external box ID. If box IDs are duplicated or the runtime configuration is incomplete, the current docking station will not be correctly communicated to the PLC. |
| Why does the Mobile Panel 177 DP not start after power-up? | Siemens identifies the first check point as the wiring on the terminal block. If the device does not start after power is applied, the wiring may be incorrect or swapped. Therefore, the power supply, connection box, and terminal assignment should be fully checked and then tested again. |
Is 6AV6645-0AC01-0AX0 still an active Siemens product?
No. For this specific order number, an EOP date of 01.10.2021 is specified. In addition, Siemens announced the Mobile Panel 177/277 family as end-of-life already on 01.10.2016.
For operators, this mainly means today a higher procurement risk, longer sourcing times on the spare parts market, and increased relevance of repair, exchange, and spare parts stocking strategies.
Which software is required for engineering, service, and legacy systems?
The product documentation specifies WinCC flexible Compact (from version 2005) as well as TIA Portal V11 to V14. Technical data also list WinCC flexible Compact, Standard and Advanced, and in TIA Portal WinCC Comfort, Advanced and Professional as supported environments, while WinCC Basic is not supported.
For operators of legacy systems, this is important because the correct engineering environment determines whether project maintenance, transfer, and service operations can be carried out without media breaks.
Is there a direct Siemens successor for 6AV6645-0AC01-0AX0?
There is no clearly defined 1:1 successor for this order number from Siemens. In the official release for Mobile Panels of the second generation, Siemens explicitly states that there is no migration path to KTP-Mobile for 6AV6645-0AC01-0AX0.
This means a simple replacement is not possible without technical evaluation and project adaptation. For modernization projects, the machine architecture, communication system, and safety functions must therefore always be assessed individually.
When is repair more suitable than replacement or refurbished units?
Repair is especially suitable when the existing operating concept must remain unchanged and the machine needs to return quickly to operation with the same device type. Exchange units are preferable when downtime is critical and an immediately tested replacement is required. Refurbished units are useful for economically maintaining older systems or building spare part inventories.
On the EICHLER product page, all three options are available for this MLFB, and a test report can be provided as well.
Is the Mobile Panel suitable for safety-related machine operation?
Yes. The device is clearly designed for machine-level operation. This is supported by integrated elements such as an enabling switch, STOP button, handwheel, key switch, and illuminated pushbuttons.
According to technical specifications, the panel is suitable for safety-related applications up to Performance Level d (ISO 13849-1) in safety mode. However, the actual machine integration and safety validation must always be assessed on a system-specific basis.
What should procurement and maintenance pay special attention to today?
Key factors are the exact order number 6AV6645-0AC01-0AX0, the DP-based version, the integrated operator elements, the correct connection box, and the required engineering environment.
From a procurement perspective, it is also important to determine whether a tested device, an exchange unit, or a repair is the most economical solution. Technically, the panel is based on RS422/RS485 and PROFIBUS, and does not support Industrial Ethernet or USB.
For legacy systems, this verification is essential to avoid incorrect purchases and unnecessary downtime.