6ES7332-5HF00-0AB0
-
SIEMENS | PLC Controls | Sales Offer
- EICHLER-art.no.: K0118586
- EAN: 4025515068686
- UPC: 040892561203
SIMATIC S7-300, ANALOG OUTPUT SM 332, ISOLATED, 8 AO, U/I; DIAGNOSTICS; RESOLUTION 11/12 BITS, 40-POLE, REMOVING AND INSERTING POSSIBLE WITH ACTIVE BACKPLANE BUS
- EICHLER-art.no.: K0118586
- EAN: 4025515068686
- UPC: 040892561203
SIMATIC S7-300, ANALOG OUTPUT SM 332, ISOLATED, 8 AO, U/I; DIAGNOSTICS; RESOLUTION 11/12 BITS, 40-POLE, REMOVING AND INSERTING POSSIBLE WITH ACTIVE BACKPLANE BUS
from 472,16 €
to 1.028,30 €
1.462,13 €
1.096,60 €
1.624,59 €
1.218,44 €
1.805,10 €
1.353,82 €
SIEMENS |
6ES7332-5HF00-0AB0 –
additional product information
| Delivery information | |||
|---|---|---|---|
| Export identifier | AL: N ECCN: EAR99H | ||
| Net weight | 0.33 | ||
| Quantity | 1 Stück | ||
| Packaging quantity | 1 | ||
| Additional product information | |||
|---|---|---|---|
| Product status | |||
| EAN | 4025515068686 | ||
| UPC | 040892561203 | ||
| Static lot number | 85389099 | ||
| List indicator | ST73 | ||
| Product group | 4561 | ||
| Country of origin | DE | ||
| Compliance with the substance restrictions according to RoHS directive | Since: 20081231 | ||
| Product classifications | Version | Classification | |
|---|---|---|---|
| eClass | 4 | 27-24-03-05 | |
| eClass | 5.1 | 27-24-22-01 | |
| eClass | 6.0 | 27-24-22-01 | |
| ETIM | 3 | / | |
| ETIM | 4 | EC001420 | |
| ETIM | 5 | EC001420 | |
| Supply voltage | |
|---|---|
| Load voltage L+ | |
| ● Rated value (DC) | 24 V |
| ● Reverse polarity protection | Yes |
| Input current | |
| from load voltage L+ (without load), max. | 340 mA |
| from backplane bus 5 V DC, max. | 100 mA |
| Power loss | |
| Power loss, typ. | 6 W |
| Analog outputs | |
| Number of analog outputs | 8 |
| Voltage output, short-circuit protection | Yes |
| Voltage output, short-circuit current, max. | 25 mA |
| Current output, no-load voltage, max. | 18 V |
| Output ranges, voltage | |
| ● 0 to 10 V | Yes |
| ● 1 V to 5 V | Yes |
| ● -10 V to +10 V | Yes |
| Output ranges, current | |
| ● 0 to 20 mA | Yes |
| ● -20 mA to +20 mA | Yes |
| ● 4 mA to 20 mA | Yes |
| Load impedance (in rated range of output) | |
| ● with voltage outputs, min. | 1 kΩ |
| ● with voltage outputs, capacitive load, max. | 1 µF |
| ● with current outputs, max. | 500 Ω |
| ● with current outputs, inductive load, max. | 10 mH |
| Cable length | |
| ● shielded, max. | 200 m |
| Analog value generation for the outputs | |
| Integration and conversion time/resolution per channel | |
| ● Resolution with overrange (bit including sign), max. | 12 bit; ±10 V, ±20 mA, 4 mA to 20 mA, 1 V to 5 V: 11 bit + sign; 0 V to 10 V, 0 mA to 20 mA: 12 bit |
| ● Conversion time (per channel) | 0.8 ms |
| Settling time | |
| ● for resistive load | 0.2 ms |
| ● for capacitive load | 3.3 ms |
| ● for inductive load | 0.5 ms; 0.5 ms (1 mH); 3.3 ms (10 mH) |
| Errors/accuracies | |
| Operational error limit in overall temperature range | |
| ● Voltage, relative to output range, (+/-) | 0.5 % |
| ● Current, relative to output range, (+/-) | 0.6 % |
| Basic error limit (operational limit at 25 °C) | |
| ● Voltage, relative to output range, (+/-) | 0.4 % |
| ● Current, relative to output range, (+/-) | 0.5 % |
| Interrupts/diagnostics/status information | |
| Diagnostics function | Yes; Parameterizable |
| Alarms | |
| ● Diagnostic alarm | Yes; Parameterizable |
| Diagnoses | |
| ● Diagnostic information readable | Yes |
| Diagnostics indication LED | |
| ● Group error SF (red) | Yes |
| Potential separation | |
| Potential separation analog outputs | |
| ● between the channels | No |
| ● between the channels and backplane bus | Yes |
| ● Between the channels and load voltage L+ | Yes |
| ● between the channels and the power supply of the electronics | Yes |
| Isolation | |
| Isolation tested with | 500 V DC |
| Connection method | |
| required front connector | 40-pin |
| Dimensions | |
| Width | 40 mm |
| Height | 125 mm |
| Depth | 117 mm |
| Weights | |