6ES7331-7PF01-0AB0
-
SIEMENS | PLC Controls | Sales Offer
- EICHLER-art.no.: K0139375
- EAN: 4025515071549
- UPC: 662643177916
SIMATIC S7-300, ANALOG INPUT SM 331, ISOLATED, 2/3/4-WIRE, 8 AI, RESISTOR, PT100/200/1000 NI100/120/200/500/1000, CU10, CHARACTERISTICS ACCORDING TO GOST 16 (INTERNAL 24) BIT, 50MS, 1X 40-POLE
- EICHLER-art.no.: K0139375
- EAN: 4025515071549
- UPC: 662643177916
SIMATIC S7-300, ANALOG INPUT SM 331, ISOLATED, 2/3/4-WIRE, 8 AI, RESISTOR, PT100/200/1000 NI100/120/200/500/1000, CU10, CHARACTERISTICS ACCORDING TO GOST 16 (INTERNAL 24) BIT, 50MS, 1X 40-POLE
from 218,40 €
to 1.341,60 €
1.120,88 €
840,66 €
1.245,43 €
934,07 €
1.383,80 €
1.037,85 €
SIEMENS |
6ES7331-7PF01-0AB0 –
additional product information
| Delivery information | |||
|---|---|---|---|
| Export identifier | AL: N ECCN: EAR99H | ||
| Net weight | 0.33 | ||
| Quantity | 1 Stück | ||
| Packaging quantity | 1 | ||
| Additional product information | |||
|---|---|---|---|
| Product status | EOP: 2025-10-01 | ||
| EAN | 4025515071549 | ||
| UPC | 662643177916 | ||
| Static lot number | 85389091 | ||
| List indicator | ST73 | ||
| Product group | 4561 | ||
| Country of origin | DE | ||
| Compliance with the substance restrictions according to RoHS directive | Since: 20080331 | ||
| Product classifications | Version | Classification | |
|---|---|---|---|
| eClass | 4 | 27-24-03-05 | |
| eClass | 5.1 | 27-24-22-01 | |
| eClass | 6.0 | 27-24-22-01 | |
| ETIM | 3 | / | |
| ETIM | 4 | EC001420 | |
| ETIM | 5 | EC001420 | |
| Supply voltage | |
|---|---|
| Load voltage L+ | |
| ● Rated value (DC) | 24 V |
| ● Reverse polarity protection | Yes |
| Input current | |
| from load voltage L+ (without load), max. | 240 mA |
| from backplane bus 5 V DC, max. | 100 mA |
| Power loss | |
| Power loss, typ. | 4.6 W |
| Analog inputs | |
| Number of analog inputs | 8 |
| ● For resistance measurement | 8 |
| permissible input voltage for voltage input (destruction limit), max. | 75 V; 35 V continuous, 75 V for max. 1 s (mark to space ratio 1:20) |
| Input ranges | |
| ● Voltage | No |
| ● Current | No |
| ● Thermocouple | No |
| ● Resistance thermometer | Yes |
| ● Resistance | Yes |
| Input ranges (rated values), voltages | |
| ● 0 to +10 V | No |
| ● 1 V to 5 V | No |
| ● 1 V to 10 V | No |
| ● -1 V to +1 V | No |
| ● -10 V to +10 V | No |
| ● -2.5 V to +2.5 V | No |
| ● -250 mV to +250 mV | No |
| ● -5 V to +5 V | No |
| ● -50 mV to +50 mV | No |
| ● -500 mV to +500 mV | No |
| ● -80 mV to +80 mV | No |
| Input ranges (rated values), currents | |
| ● 0 to 20 mA | No |
| ● -10 mA to +10 mA | No |
| ● -20 mA to +20 mA | No |
| ● -3.2 mA to +3.2 mA | No |
| ● 4 mA to 20 mA | No |
| Input ranges (rated values), thermocouples | |
| ● Type B | No |
| ● Type C | No |
| ● Type E | No |
| ● Type J | No |
| ● Type K | No |
| ● Type L | No |
| ● Type N | No |
| ● Type R | No |
| ● Type S | No |
| ● Type T | No |
| ● Type U | No |
| ● Type TXK/TXK(L) to GOST | No |
| Input ranges (rated values), resistance thermometer | |
| ● Cu 10 | Yes |
| ● Ni 100 | Yes |
| ● Ni 1000 | Yes |
| ● LG-Ni 1000 | Yes |
| ● Ni 120 | Yes |
| ● Ni 200 | Yes |
| ● Ni 500 | Yes |
| ● Pt 100 | Yes |
| ● Pt 1000 | Yes |
| ● Pt 200 | Yes |
| ● Pt 500 | Yes |
| Input ranges (rated values), resistors | |
| ● 0 to 150 ohms | Yes |
| ● 0 to 300 ohms | Yes |
| ● 0 to 600 ohms | Yes |
| Characteristic linearization | |
| ● parameterizable | Yes |
| — for resistance thermometer | Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni200, Ni500, Ni1000, Cu10; (standard/climate) |
| Cable length | |
| ● shielded, max. | 200 m |
| Analog value generation for the inputs | |
| Integration and conversion time/resolution per channel | |
| ● Resolution with overrange (bit including sign), max. | 16 bit; Two's complement |
| ● Integration time, parameterizable | Yes |
| ● Basic conversion time (ms) | up to 4 channels: 10 ms per module, over 5 channels: 190 ms per module, 8 channels: 80 ms |
| ● Interference voltage suppression for interference frequency f1 in Hz | 400 / 60 / 50 Hz |
| Encoder | |
| Connection of signal encoders | |
| ● for resistance measurement with two-wire connection | Yes; without resistance correction |
| ● for resistance measurement with three-wire connection | Yes |
| ● for resistance measurement with four-wire connection | Yes |
| Errors/accuracies | |
| Operational error limit in overall temperature range | |
| ● Resistance, relative to input range, (+/-) | 0.1 % |
| ● Resistance thermometer, relative to input range, (+/-) | ±1 K |
| Basic error limit (operational limit at 25 °C) | |
| ● Resistance, relative to input range, (+/-) | 0.05 % |
| ● Resistance thermometer, relative to input range, (+/-) | ±0.5 K |
| Interrupts/diagnostics/status information | |
| Diagnostics function | Yes; Parameterizable |
| Alarms | |
| ● Diagnostic alarm | Yes; Parameterizable per group |
| ● Limit value alarm | Yes; Parameterizable |
| ● Hardware interrupt | Yes; Parameterizable, channels 0 to 7 |
| Diagnoses | |
| ● Diagnostic information readable | Yes |
| Diagnostics indication LED | |
| ● Group error SF (red) | Yes |
| Potential separation | |
| Potential separation analog inputs | |
| ● between the channels | Yes |
| ● between the channels, in groups of | 2 |
| ● between the channels and backplane bus | Yes |
| ● between the channels and the power supply of the electronics | Yes |
| Isolation | |
| Isolation tested with | 500 V DC |
| Connection method | |
| required front connector | 40-pin |
| Dimensions | |
| Width | 40 mm |
| Height | 125 mm |
| Depth | 120 mm |
| Weights | |
| Weight, approx. | 272 g |