SIMATIC S7-300, ANALOG INPUT SM 331, ISOLATED, 2/3/4-WIRE, 8 AI, RESISTOR, PT100/200/1000 NI100/120/200/500/1000, CU10, CHARACTERISTICS ACCORDING TO GOST 16 (INTERNAL 24) BIT, 50MS, 1X 40-POLE

  • EICHLER-art.no.: K0139375
  • EAN: 4025515071549
  • UPC: 662643177916

SIMATIC S7-300, ANALOG INPUT SM 331, ISOLATED, 2/3/4-WIRE, 8 AI, RESISTOR, PT100/200/1000 NI100/120/200/500/1000, CU10, CHARACTERISTICS ACCORDING TO GOST 16 (INTERNAL 24) BIT, 50MS, 1X 40-POLE

2-5 days

from 218,40 €

to 1.341,60 €

Note: Our repairs always include technical cleaning, preventive maintenance, a comprehensive functional test, and at least a 24-month warranty.

Our services are aimed exclusively at companies.

1-3 days

10+ Pcs.

1.120,88 €

840,66 €

840,66 € *

* plus VAT, freight/packaging costs and, if applicable, customs and atlas fees.
Note: Our services are aimed exclusively at companies.

Please enter an offer recipient here.


1-3 days

10+ Pcs.

1.245,43 €

934,07 €

934,07 € *

* plus VAT, freight/packaging costs and, if applicable, customs and atlas fees.
Note: Our services are aimed exclusively at companies.

Please enter an offer recipient here.


1-3 days

10+ Pcs.

1.383,80 €

1.037,85 €

1.037,85 € *

* plus VAT, freight/packaging costs and, if applicable, customs and atlas fees.
Note: Our services are aimed exclusively at companies.

Please enter an offer recipient here.


Delivery information
Export identifier AL: N ECCN: EAR99H
Net weight 0.33
Quantity 1 Stück
Packaging quantity 1
Additional product information
Product status EOP: 2025-10-01
EAN 4025515071549
UPC 662643177916
Static lot number 85389091
List indicator ST73
Product group 4561
Country of origin DE
Compliance with the substance restrictions according to RoHS directive Since: 20080331
Product classifications Version Classification
eClass 4 27-24-03-05
eClass 5.1 27-24-22-01
eClass 6.0 27-24-22-01
ETIM 3 /
ETIM 4 EC001420
ETIM 5 EC001420

Supply voltage
Load voltage L+
● Rated value (DC) 24 V
● Reverse polarity protection Yes
Input current
from load voltage L+ (without load), max. 240 mA
from backplane bus 5 V DC, max. 100 mA
Power loss
Power loss, typ. 4.6 W
Analog inputs
Number of analog inputs 8
● For resistance measurement 8
permissible input voltage for voltage input (destruction limit), max. 75 V; 35 V continuous, 75 V for max. 1 s (mark to space ratio 1:20)
Input ranges
● Voltage No
● Current No
● Thermocouple No
● Resistance thermometer Yes
● Resistance Yes
Input ranges (rated values), voltages
● 0 to +10 V No
● 1 V to 5 V No
● 1 V to 10 V No
● -1 V to +1 V No
● -10 V to +10 V No
● -2.5 V to +2.5 V No
● -250 mV to +250 mV No
● -5 V to +5 V No
● -50 mV to +50 mV No
● -500 mV to +500 mV No
● -80 mV to +80 mV No
Input ranges (rated values), currents
● 0 to 20 mA No
● -10 mA to +10 mA No
● -20 mA to +20 mA No
● -3.2 mA to +3.2 mA No
● 4 mA to 20 mA No
Input ranges (rated values), thermocouples
● Type B No
● Type C No
● Type E No
● Type J No
● Type K No
● Type L No
● Type N No
● Type R No
● Type S No
● Type T No
● Type U No
● Type TXK/TXK(L) to GOST No
Input ranges (rated values), resistance thermometer
● Cu 10 Yes
● Ni 100 Yes
● Ni 1000 Yes
● LG-Ni 1000 Yes
● Ni 120 Yes
● Ni 200 Yes
● Ni 500 Yes
● Pt 100 Yes
● Pt 1000 Yes
● Pt 200 Yes
● Pt 500 Yes
Input ranges (rated values), resistors
● 0 to 150 ohms Yes
● 0 to 300 ohms Yes
● 0 to 600 ohms Yes
Characteristic linearization
● parameterizable Yes
— for resistance thermometer Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni200, Ni500, Ni1000, Cu10; (standard/climate)
Cable length
● shielded, max. 200 m
Analog value generation for the inputs
Integration and conversion time/resolution per channel
● Resolution with overrange (bit including sign), max. 16 bit; Two's complement
● Integration time, parameterizable Yes
● Basic conversion time (ms) up to 4 channels: 10 ms per module, over 5 channels: 190 ms per module, 8 channels: 80 ms
● Interference voltage suppression for interference frequency f1 in Hz 400 / 60 / 50 Hz
Encoder
Connection of signal encoders
● for resistance measurement with two-wire connection Yes; without resistance correction
● for resistance measurement with three-wire connection Yes
● for resistance measurement with four-wire connection Yes
Errors/accuracies
Operational error limit in overall temperature range
● Resistance, relative to input range, (+/-) 0.1 %
● Resistance thermometer, relative to input range, (+/-) ±1 K
Basic error limit (operational limit at 25 °C)
● Resistance, relative to input range, (+/-) 0.05 %
● Resistance thermometer, relative to input range, (+/-) ±0.5 K
Interrupts/diagnostics/status information
Diagnostics function Yes; Parameterizable
Alarms
● Diagnostic alarm Yes; Parameterizable per group
● Limit value alarm Yes; Parameterizable
● Hardware interrupt Yes; Parameterizable, channels 0 to 7
Diagnoses
● Diagnostic information readable Yes
Diagnostics indication LED
● Group error SF (red) Yes
Potential separation
Potential separation analog inputs
● between the channels Yes
● between the channels, in groups of 2
● between the channels and backplane bus Yes
● between the channels and the power supply of the electronics Yes
Isolation
Isolation tested with 500 V DC
Connection method
required front connector 40-pin
Dimensions
Width 40 mm
Height 125 mm
Depth 120 mm
Weights
Weight, approx. 272 g
Important documents

Repair accompanying note

Download the repair accompanying note as a PDF, or use the digital repair registration and send your defective modules to the EICHLER Service Centre for repair.

Laughing Eichler technician points to green PDF with special sale of automation technology
Quality & warranty

Outstanding service quality with every handle

Two Eichler technicians high-five each other after a successful repair

Your shopping basket

There are currently no items in your shopping basket.

Loading shopping basket