SIEMENS 6ES7136-6DB00-0CA0

  • EICHLER-art.no.: K0370488
  • EAN: 4025515082750
  • UPC: 887621549763

Product description

SIMATIC DP, ELECTRON. MODULE F. ET 200SP, F-DQ 4XDC 24V/2A, 15 MM WIDTH, UP TO PL E (ISO 13849) UP TO SIL 3 (IEC 61508)

Services for SIEMENS 6ES7136-6DB00-0CA0

Repair

2-5 days

from 234,73 €

to 359,00 €

Replacement

Used

New

1-3 days

10+ Pcs.

197,25 €

197,25 € *

Please enter an offer recipient here.


Delivery information
Export identifier AL: N ECCN: EAR99H
Net weight 0.064
Quantity 1 Stück
Packaging quantity 1
Additional product information
Product status
EAN 4025515082750
UPC 887621549763
Static lot number 85389091
List indicator ST76
Product group 4527
Country of origin DE
Compliance with the substance restrictions according to RoHS directive Since: 20130808
Product classifications Version Classification
eClass 4 /
eClass 5.1 27-24-26-04
eClass 6.0 27-24-26-04
ETIM 3 /
ETIM 4 EC001599
ETIM 5 EC001599

Attribute Value
General information
Product type designation F-DQ 4x24VDC/2A PM HF
usable BaseUnits BU type A0
Product function
● I&M data Yes; I&M0 to I&M3
Engineering with
● STEP 7 TIA Portal configurable/integrated from version V12
● STEP 7 configurable/integrated from version V5.5 SP3 / -
● PROFINET from GSD version/GSD revision V2.31
Supply voltage
Rated value (DC) 24 V
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V
Reverse polarity protection Yes
power supply according to NEC Class 2 required No
Input current
Current consumption (rated value) 75 mA; without load
Current consumption, max. 21 mA; From the backplane bus
Output voltage
Rated value (DC) 24 V
Power
Power consumption from the backplane bus 70 mW
Power loss
Power loss, typ. 4 W
Address area
Address space per module
● Inputs 5 byte
● Outputs 5 byte
Hardware configuration
Automatic encoding Yes
● Electronic coding element type F Yes
Digital outputs
Type of digital output Transistor
Number of digital outputs 4
Digital outputs, parameterizable Yes
Short-circuit protection Yes
● Response threshold, typ. > 3.3 A
Open-circuit detection Yes
● Response threshold, typ. 8 mA
Overload protection Yes
● Response threshold, typ. 2.9 A
Limitation of inductive shutdown voltage to Typ. -2x 47 V
Controlling a digital input Yes; digital output, according to IEC 61131-2, type 2
Switching capacity of the outputs
● with resistive load, max. 2 A
● on lamp load, max. 10 W
Load resistance range
● lower limit 12 Ω
● upper limit 2 000 Ω
Output voltage
● for signal "1", min. 24 V; L+ (-0.5 V)
Output current
● for signal "1" rated value 2 A
● for signal "0" residual current, max. 0.5 mA
Switching frequency
● with resistive load, max. 30 Hz; Symmetrical
● with inductive load, max. 0.1 Hz; according to IEC 60947-5-1, DC-13, symmetrical
● on lamp load, max. 10 Hz; Symmetrical
Total current of the outputs
● Current per channel, max. 2 A; note derating data in the manual
● Current per module, max. 6 A; note derating data in the manual
Cable length
● shielded, max. 1 000 m
● unshielded, max. 500 m
Interrupts/diagnostics/status information
Diagnostics function Yes; See Chapter "Alarms/diagnostic messages" in the manual
Substitute values connectable No
Alarms
● Diagnostic alarm Yes
● Hardware interrupt No
Diagnostics indication LED
● RUN LED Yes; green LED
● ERROR LED Yes; red LED
● Monitoring of the supply voltage (PWR-LED) Yes; green PWR LED
● Channel status display Yes; green LED
● for channel diagnostics Yes; red LED
● for module diagnostics Yes; green/red DIAG LED
Potential separation
Potential separation channels
● between the channels No
● between the channels and backplane bus Yes
● between the channels and the power supply of the electronics No
Isolation
Isolation tested with 707 V DC (type test)
Standards, approvals, certificates
Suitable for safety functions Yes
Ecological footprint
● environmental product declaration Yes
Global warming potential
— global warming potential, (total) [CO2 eq] 88.3 kg
— global warming potential, (during production) [CO2 eq] 13.1 kg
— global warming potential, (during operation) [CO2 eq] 76.6 kg
— global warming potential, (after end of life cycle) [CO2 eq] -1.37 kg
Highest safety class achievable in safety mode
● Performance level according to ISO 13849-1 PLe
● SIL acc. to IEC 61508 SIL 3
Probability of failure (for service life of 20 years and repair time of 100 hours)
— Low demand mode: PFDavg in accordance with SIL2 < 2.00E-04
— Low demand mode: PFDavg in accordance with SIL3 < 2.00E-05
— High demand/continuous mode: PFH in accordance with SIL2 < 1.00E-08 1/h
— High demand/continuous mode: PFH in accordance with SIL3 < 1.00E-09 1/h
Ambient conditions
Ambient temperature during operation
● horizontal installation, min. 0 °C
● horizontal installation, max. 60 °C
● vertical installation, min. 0 °C
● vertical installation, max. 50 °C
Altitude during operation relating to sea level
● Installation altitude above sea level, max. 4 000 m; Restrictions for installation altitudes > 2 000 m, see manual
Dimensions
Width 15 mm
Height 73 mm
Depth 58 mm
Weights
Weight, approx. 57 g

Important documents

Repair accompanying note

Download the repair accompanying note as a PDF, or use the digital repair registration and send your defective modules to the EICHLER Service Centre for repair.

Laughing Eichler technician points to green PDF with special sale of automation technology

Your shopping basket

Loading shopping basket