SIEMENS 6GK1162-3AA00

  • SIEMENS | PLC Controls | Communication Modules

  • EICHLER-art.no.: K0222979
  • EAN: 4019169160506
  • UPC: 662643424430

Product description

COMMUNICATION PROCESSOR CP 1623 PCI EXPRESS X1 (3.3V/12V) FOR CONNECTING WITH IND.ETHERNET(10/100/1000MBIT/S) WITH 2-PORT-SWITCH(RJ45) VIA HARDNET-IE S73 AND S7-REDCONNECT SUPPORT FOR OPERATING SYSTEM SEE SIMATIC NET SW ENABLED FOR SIMATIC NET CD V7.0 HF1 OR HIGHER

Services for SIEMENS 6GK1162-3AA00

Repair

2-5 days

from 917,49 €

to 1.349,25 €

Replacement

Used

New

1-3 days

1 Pcs.

1.798,00 €

1.798,00 € *

Please enter an offer recipient here.


Delivery information
Export identifier AL: N ECCN: 5A991X
Net weight 0.212
Quantity 1 Stück
Packaging quantity 1
Additional product information
Product status EOP: 2027-10-01
EAN 4019169160506
UPC 662643424430
Static lot number 85176200
List indicator IK
Product group 2417
Country of origin DE
Compliance with the substance restrictions according to RoHS directive Since: 20030101
Product classifications Version Classification
eClass 4 27-25-05-03
eClass 5.1 27-24-06-01
eClass 6.0 19-17-01-01
ETIM 3 /
ETIM 4 EC002631
ETIM 5 EC000515

What is 6GK1162-3AA00 and where is it used?

The 6GK1162-3AA00 is the Siemens SIMATIC NET CP 1623 communication processor. It is a PCI Express x1 communication module for PGs, PCs, and industrial PCs that need to be connected to Industrial Ethernet. The module features two RJ45 ports and an integrated 2-port switch. Typical use cases include PC-based automation systems, engineering stations, operator stations, and communication PCs running with SIMATIC NET, HARDNET-IE S7, or S7-REDCONNECT. For maintenance teams and purchasing departments, the CP 1623 is especially relevant where existing Siemens PC stations must remain in operation without major architectural changes, be restored quickly after failure, or be secured with suitable spare units.

Overview of the key technical data and what it means

The CP 1623 supports 10/100/1000 Mbps and provides two RJ45 interfaces. Mechanically, the module is designed for PCI Express x1, but it can also be installed in x4, x8, or x16 slots. An optional external power supply is also possible; Siemens specifies 12 to 24 V DC nominal and 10.5 to 32 V DC permissible. In practice, this matters because the integrated switch can continue operating even when the PC is powered off, provided external power is connected. Siemens also allows up to four CP 1623 modules per PG/PC. For operators, this means the module is suitable for demanding communication tasks, but it requires proper planning of slot power, cooling, and configuration.

Product status, life-cycle status, and obsolescence

The 6GK1162-3AA00 has been in phase-out status (PM400) since June 1, 2026. This means the CP 1623 may still be available for ordering for the time being, but Siemens is no longer actively marketing it. The planned product discontinuation (PM410) is scheduled for December 10, 2027. Siemens does not name a directly compatible successor for the CP 1623. For certain applications, Siemens instead refers to standard network interface cards used together with SOFTNET-IE S7 or SOFTNET-IE S7 REDCONNECT; however, this does not automatically provide a 1:1 replacement for existing installations. For operators of installed systems, this significantly increases the importance of a reliable strategy for spare part stocking, repair, technical evaluation, and migration planning.

Available EICHLER services and when they are relevant

For the 6GK1162-3AA00, EICHLER offers repair, exchange, used units, and new units. Repair is especially relevant when an existing PC station needs to be restored to its original operating condition with as little change as possible. EICHLER states that this includes technical cleaning, preventive maintenance, comprehensive functional testing, and a minimum 24-month warranty. Exchange is the right option when downtime pressure is high. Used modules help secure legacy systems economically when obsolescence risks are increasing. New units remain particularly relevant during the current PM400 phase, as long as strategic purchasing and planned stock building are still possible. In this way, EICHLER’s services support both short-term availability goals and a structured obsolescence strategy.

Attribute Value
product brand name SIMATIC NET
transfer rate
transfer rate 10, 100, 1000 Mbit/s
interfaces
number of electrical connections
● at the 1st interface / according to Industrial Ethernet 2
● for power supply 1
type of electrical connection
● at the 1st interface / according to Industrial Ethernet RJ45 port
● of the backplane bus PCI Express x1
● for power supply 2-pole terminal block
supply voltage, current consumption, power loss
type of voltage / of the supply voltage DC
type of voltage supply / optional external power supply Yes
supply voltage
● 1 / from backplane bus 3.3 V
● 2 / from backplane bus 12 V
● external 24 V
● external 10.5 ... 32 V
relative symmetrical tolerance / at DC
● at 3.3 V 9 %
● at 5 V 5 %
● at 12 V 8 %
● at 24 V 33 %
consumed current
● 1 / from backplane bus / at DC / maximum 0.85 A
● 2 / from backplane bus / at DC / maximum 0.4 A
● from external supply voltage / at DC / at 12 V / maximum 0.55 A
● from external supply voltage / at DC / at 24 V / maximum 0.3 A
power loss [W] 7.6 W
power loss [W] / in switch mode / maximum 7.2 W
ambient conditions
ambient temperature
● during operation 5 ... 55 °C
● during storage -20 ... +60 °C
● during transport -20 ... +60 °C
relative humidity / at 25 °C / without condensation / during operation / maximum 95 %
protection class IP IP00
design, dimensions and weights
module format PCI Express x1 (half length)
width 18 mm
height 111 mm
depth 167 mm
net weight 124 g
product features, product functions, product components / general
number of plug-in cards of same design / plug-in / per PC station 4
number of units / note -
performance data / open communication
software / for open communication / by means of SEND/RECEIVE / required Yes, HARDNET-IE S7 (S7-1613)
number of possible connections / for open communication / by means of SEND/RECEIVE / maximum 120
performance data / S7 communication
software / for S7 communication / required Yes, HARDNET-IE S7 (S7-1613)
number of possible connections / for S7/PG communication / maximum 120
number of possible connections / for optimized S7 communication / maximum 40
performance data / multi-protocol mode
number of active connections / with multi-protocol mode 120
number of configurable connections / per PC station 207
performance data / PROFINET CBA
software / for PROFINET CBA communication / required Yes, PN CBA OPC server
number of remote connection partners / with PROFINET CBA 228
number of connections / with PROFINET CBA / total 10000
product functions / management, configuration, engineering
product function / MIB support Yes
protocol / is supported
● SNMP v1 Yes
● SNMP v3 No
● DCP Yes
● LLDP No
configuration software / required Included in the scope of delivery of the required software product
configuration software / for PROFINET CBA / required Yes, SIMATIC iMAP
identification & maintenance function
● I&M0 - device-specific information Yes
● I&M1 - higher level designation/location designation Yes
● I&M2 - installation date No
● I&M3 - comment No
● I&M4 - signature No
● I&M4 - OEM data No
product functions / switch
product feature / switch Yes
product function / switch-managed No
product function / with IRT / PROFINET IO switch No
product functions / redundancy
software / for redundancy function / required Yes, HARDNET-IE S7-REDCONNECT for communication with SIMATIC S7 H systems
product functions / time
product function / SICLOCK support Yes
protocol / is supported / NTP No
standards, specifications, approvals / Environmental Product Declaration
Environmental Product Declaration Yes
global warming potential [CO2 eq]
● total 240.36 kg
● during manufacturing 33.2 kg
● during operation 207.09999 kg
● after end of life 0.06 kg

Error description Possible solution
Why is the CP 1623 not detected after installation in Windows? A common cause is that the required SIMATIC NET PC software has not been installed. Siemens states that the CP 1613 / CP 1623 requires a SIMATIC NET installation for operation. First check that the module is seated correctly in the PCIe slot, then install or repair the correct SIMATIC NET environment and restart the PC afterward.
Why do the CP 1623 ports not work like a normal network card? The CP 1623 is not a simple standard Ethernet adapter. Only after SIMATIC NET has been installed does the CP 16xx become available both for S7 communication and as a Windows network card. Always verify that the hardware, software version, configuration, and communication path match the intended application.
Why does the integrated 2-port switch stop working as soon as the PC is turned off? Siemens states that the CP 1623 can only continue operating as a 2-port switch when the PC is powered off if an external power supply is connected. Check the wiring on the 2-pin connector and verify that the supply voltage is within the permitted range of 12 to 24 V DC nominal or 10.5 to 32 V DC permissible.
Why does a PC with an installed CP 1623 run unstably or show a Windows blue screen? According to Siemens, under certain operating systems a BSOD can occur in connection with enabled Kernel DMA Protection, including Windows 10 Enterprise 2016 LTSB, Windows 10 Enterprise 2019 LTSC, Windows Server 2016, and Windows Server 2019. Siemens identifies upgrading to newer operating systems such as Windows 10 Enterprise 2021 LTSC or Windows Server 2022 or later as the clean solution.
Why do communication problems occur when several CP 1623 cards are installed in one PC? Siemens permits a maximum of four CP 1623 modules per PG/PC. At the same time, the PCIe slot power supply, enclosure cooling, and thermal reserve of the system must be properly designed. In multi-card setups, the power supply, airflow, and operating temperature should therefore be checked very carefully.

Is 6GK1162-3AA00 still active or already in phase-out?

The 6GK1162-3AA00 has been in PM400 phase-out status since June 1, 2026. This means the module may still be orderable for the time being, but Siemens is no longer actively marketing it. For operators of existing systems, this is a clear signal to assess installed stock, system criticality, and future spare-part strategies now. The planned PM410 product discontinuation is scheduled for December 10, 2027.

What does PM400 mean in practical terms for purchasing and maintenance?

PM400 marks the official start of the product phase-out. For purchasing, this means new procurement may still be possible, but long-term supply security is decreasing. For maintenance teams, this is the right time to identify installed CP 1623 units, prioritize critical systems, and decide where repair, stocking, exchange, or migration makes the most economic sense.

Is there a directly compatible successor to the CP 1623?

No. Siemens does not name a directly compatible successor for the CP 1623. For certain applications, Siemens refers to standard network cards together with SOFTNET-IE S7 or SOFTNET-IE S7 REDCONNECT. This alternative may be suitable in individual cases, but it does not automatically replace existing HARDNET-IE S7 or REDCONNECT architectures without a detailed technical review of configuration, redundancy concept, software version, and approvals.

Until when can 6GK1162-3AA00 still be procured as a new unit?

According to the current notice, PM410 product discontinuation is planned for December 10, 2027. Until then, the module may still remain within the regular procurement window, provided orderability and stock availability are still in place. For critical systems, this period should be used proactively to evaluate spare part demand, repair options, and migration effort before time pressure arises.

Is SIMATIC NET mandatory for 6GK1162-3AA00?

Yes. Siemens explicitly states that the CP 1613 / CP 1623 requires a SIMATIC NET installation for operation. Only then is the module available both for S7 communication and as a Windows network card. For purchasing and maintenance, this is important because having the hardware alone does not guarantee a functioning system. What matters is the interaction between the module, SIMATIC NET version, configuration, and licensing environment.

When is repair more sensible than technical migration?

Repair is usually the better option when existing PC stations need to continue operating with as few changes as possible to software, configuration, validation, and approvals. Especially during the PM400 phase, repair helps avoid unplanned conversions and buys time for a structured modernization decision. It is particularly attractive when system downtime would be more expensive than restoring the existing module and when the current communication architecture is still stable and suitable for continued use.

Can the CP 1623 also be installed in larger PCIe slots?

Yes. Siemens specifies PCI Express x1 as the bus interface, but the manual also states that the CP 1623 can be operated in x4, x8, or x16 slots. This is useful for retrofit projects and spare-part management, because industrial PCs often do not have an identical free slot type available. Even so, the PC’s space conditions, cooling, and power supply should always be checked before installation.

Important documents

Repair accompanying note

Download the repair accompanying note as a PDF, or use the digital repair registration and send your defective modules to the EICHLER Service Centre for repair.

Laughing Eichler technician points to green PDF with special sale of automation technology

Your shopping basket

Loading shopping basket