Product description
SIMATIC Multi Panel MP 370 12" color TFT display, Touch Windows CE 3.0 configurable with ProTool From Version V5.2+SP3
Services for SIEMENS 6AV6545-0DA10-0AX0
SIEMENS |
6AV6545-0DA10-0AX0 –
additional product information
| Delivery information | |||
|---|---|---|---|
| Export identifier | AL: ECCN: | ||
| Net weight | 3.6 | ||
| Quantity | 1 Stück | ||
| Packaging quantity | 1 | ||
| Additional product information | |||
|---|---|---|---|
| Product status | EOP: 2008-08-01 | ||
| EAN | 4025515066668 | ||
| UPC | / | ||
| Static lot number | 85371098 | ||
| List indicator | / | ||
| Product group | / | ||
| Country of origin | DE | ||
| Compliance with the substance restrictions according to RoHS directive | Since: / | ||
| Product classifications | Version | Classification | |
|---|---|---|---|
| eClass | 4 | / | |
| eClass | 5.1 | / | |
| eClass | 6.0 | / | |
| ETIM | 3 | / | |
| ETIM | 4 | / | |
| ETIM | 5 | / | |
What is 6AV6545-0DA10-0AX0 and where is it used?
The 6AV6545-0DA10-0AX0 is a SIEMENS SIMATIC Multi Panel MP370 12" Touch. It is an industrial HMI operator panel featuring a 12.1-inch colour TFT display, touchscreen operation, Windows CE 3.0, and engineering support via ProTool from Version 5.2 SP3 or WinCC flexible Standard from Version 2004 onwards. The panel is typically used for machine and system operation in existing installations, where visualisation, alarms, recipes and diagnostic functions continue to run on an established MP370 platform. For maintenance personnel, the exact part number is particularly important because it enables the correct identification of the appropriate panel for fault diagnosis, spare-part identification, repair approval and replacement procurement.
Overview of the key technical specifications and their significance
The panel is equipped with a resistive analogue touchscreen, a resolution of 800 × 600 pixels, a 24 V DC power supply, a typical power consumption of 28 W, and a nominal current consumption of 1.15 A. Additional features relevant for industrial applications include IP65 protection on the front panel, IP20 protection on the rear, an operating temperature range of 0 to 50 °C, and a wide range of interfaces including TTY, 2 × RS232, RS422, RS485, Ethernet RJ45 and USB, as well as PC card and CF card slots. For operators, these specifications primarily mean excellent suitability for traditional control cabinet and machine-front installations, compatibility with legacy communication environments, and continued access to established service options for older systems. The optional 3.6 V backup battery and support for a serial UPS connection provide additional protection for data and operating states in critical applications.
Product status, life-cycle status and obsolescence
The MP370 12" Touch is listed by Siemens as a spare part, while the EICHLER product page additionally specifies an EOP (End of Production) status effective from 01 August 2008. Siemens already classified the MP370 series as a phase-out product in 2008, providing a clear indication of its obsolete status. For operators, this means that purchasing new units through traditional manufacturer channels is becoming increasingly difficult, while repair services, exchange units, used-device procurement and strategic stockholding are gaining importance. Within Siemens support documentation, the MP377 12" Touch was initially identified as the successor platform, with the TP1500 Comfort subsequently referenced as a later-generation successor. In practice, however, these alternatives should not be regarded as direct one-to-one replacements. Any migration must be carefully evaluated with regard to project migration, installation requirements, communication interfaces and commissioning procedures.
Available EICHLER services and when they are relevant
For this assembly, EICHLER offers several practical options, including repair services, exchange units, used-device procurement and new-device enquiries. According to the product page, repair, exchange and used-device options are each available with typical turnaround or delivery times of 1–3 days. For repairs, EICHLER additionally provides technical cleaning, preventive maintenance, comprehensive functional testing and a minimum 24-month warranty. For obsolete HMI assemblies in particular, these services are highly valuable for maintenance and purchasing departments because downtime can often be resolved more quickly through repair or replacement than through an immediate migration project. In addition, Life Cycle Management services help address obsolescence challenges through asset assessments, risk evaluations and supply strategies, enabling operators to systematically reduce the risk of supply shortages for ageing operator panels.
| Attribute | Value |
|---|---|
| Customer-specific configuration | No |
| Display | |
| Design of display | TFT, 256 colors |
| Screen diagonal | 12.1 in |
| Resolution (pixels) | |
| ● Horizontal image resolution | 800 Pixel |
| ● Vertical image resolution | 600 Pixel |
| Backlighting | |
| ● MTBF backlighting (at 25 °C) | 50 000 h |
| Control elements | |
| Control elements | Touch screen |
| Keyboard fonts | |
| ● Membrane keyboard | No |
| — user-definable label membrane keys | No |
| ● Function keys | |
| — Number of function keys | 0 |
| ● Numeric keyboard | Yes |
| ● alphanumeric keyboard | Yes |
| ● hexadecimal keyboard | Yes |
| ● Multi-key operation | No |
| — Number of multi-key operations | 0 |
| Touch operation | |
| ● Design as touch screen | Yes; analog, resistive |
| Connection type | |
| ● Type of connection for mouse/keyboard/barcode reader | USB / USB / USB |
| Special operator controls | |
| ● Illuminated pushbutton | Yes |
| Installation type/mounting | |
| Mounting position | vertical |
| maximum permissible angle of inclination without external ventilation | 35° |
| Supply voltage | |
| Type of supply voltage | DC |
| UPS connectable (serial) | Yes |
| Input current | |
| Current consumption (rated value) | 1.15 A |
| Starting current inrush I²t | 0.5 A²·s |
| Power | |
| Active power input, typ. | 28 W |
| Processor | |
| Processor type | MIPS |
| Memory | |
| Type of memory | Flash / RAM |
| Memory available for user data | 7 168 kbyte |
| Battery | |
| Backup battery | |
| ● Backup battery (optional) | Yes; optional 3.6 V |
| ● Backup time, min. | 3 y |
| Type of output | |
| Info LED | No |
| Power LED | No |
| Error LED | No |
| Time of day | |
| Clock | |
| ● Type | Hardware clock, battery backup, synchronizable |
| ● retentive | Yes; yes, via optional battery |
| ● synchronizable | Yes |
| Interfaces | |
| Interfaces/bus type | 1x TTY, 2x RS 232, 1x RS 422, 1x RS 485, 1x Ethernet (RJ45) (max. 12 Mbit/s) |
| USB port | Yes; 1x USB |
| PC card slot | 1x PC card slot |
| CF card slot | 1x CF card slot |
| Degree and class of protection | |
| IP (at the front) | IP65 |
| IP (rear) | IP20 |
| Standards, approvals, certificates | |
| Certificate of suitability | CE, FM Class I Div. 2, cULus, EX Zone 2/22 |
| Ambient conditions | |
| Ambient temperature during operation | |
| ● min. | 0 °C |
| ● max. | 50 °C |
| Ambient temperature during storage/transportation | |
| ● min. | -20 °C |
| ● max. | 60 °C |
| Relative humidity | |
| ● Operation, max. | 85 % |
| Operating systems | |
| pre-installed operating system | Windows CE |
| Configuration | |
| Configuration software | |
| ● Configuration tool | ProTool Version 5.2 SP 3 or higher, or WinCC flexible Standard Version 2004 or higher (to be ordered separately) |
| Languages | |
| Online languages | |
| ● Number of online/runtime languages | 5 |
| Project languages | |
| ● Languages per project | 32 |
| Functionality under WinCC (TIA Portal) | |
| Libraries | Yes |
| Number of Visual Basic Scripts | |
| ● Debugging in the simulator | No |
| Task planner | Yes |
| Help system | Yes |
| ● Number of characters per info text | 70 |
| ● Number of tooltips | 0 |
| Message system | |
| ● Number of alarm classes | 32 |
| ● Number of messages | 4 000 |
| ● Bit messages | Yes |
| — Number of bit messages | 4 000 |
| ● Analog messages | Yes |
| — Number of analog messages | 4 000 |
| ● Telegram message procedure Alarm S | Yes |
| ● System messages HMI | Yes |
| ● System messages PLC | Yes |
| ● System messages, other (SIMATIC S7, Sinumerik, Simotion, etc.) | Yes |
| ● Lines | 1 |
| ● Number of characters per message | 80 |
| ● Number of process values per message | 8 |
| ● Acknowledgment groups | Yes |
| ● Message indicator | Yes |
| ● acoustic feedback | No |
| ● First/last value | Yes |
| Recipe management | |
| ● Number of recipes | 500 |
| ● Data records per recipe | 1 000 |
| ● Entries per data record | 1 000 |
| ● Recipe memory | 128 KB integrated Flash, expandable |
| Variables | |
| ● Number of variables per device | 2 048 |
| ● Number of variables per screen | 400 |
| ● Number of variables | 2 000 |
| ● Initial values | 2 048 |
| ● Type Date & Time | 2 048 |
| ● Limit values | Yes |
| ● Multiplexing | Yes |
| ● Structures | Yes |
| Images | |
| ● Number of configurable images | 500 |
| ● Permanent window/default | Yes |
| ● Start screen configurable | Yes |
| ● Image selection by PLC | Yes |
| ● Image number in the PLC | Yes |
| Image objects | |
| ● Text objects | 30 000 text elements |
| ● Number of I/O fields per image | 400 |
| ● Number of date/time fields | 400 |
| ● Index of screen context | No |
| ● Return | Yes |
| ● Graphics object | Bit maps, icons, vector graphics |
| — Icons | 2 000 |
| — Icon (full screen) | 0 |
| Complex image objects | |
| ● Status/control | With SIMATIC S7 |
| ● dynamic objects | Diagrams, bar graphs, sliders, analog display, invisible buttons |
| — Number of objects per project | 2 000 |
| — Number of curve diagrams per image | 20 |
| ● Methods | Trend / profile |
| ● Bar graphs | |
| — Number of bars per chart | 20 |
| ● Sliders | |
| — Number of slides per image | 20 |
| ● Pointer instruments | |
| — Number of analog indicators per image | 20 |
| ● Limit value lines | Yes |
| ● Number of alphanumerical fields | 300 |
| — alphanumeric fields per image | 400 |
| ● Number of numerical fields | 2 048 |
| — numerical fields per image | 400 |
| ● Number of password fields | 2 048 |
| ● Number of visible switches per project | 400 |
| — visible switches per image | 400 |
| — hidden switches per image | 400 |
| ● Number of status switches per project | 400 |
| — Number of status switches per image | 400 |
| ● Number of selector switches per project | 400 |
| — Selector switches per image | 400 |
| ● Number of decade switches per project | 400 |
| — Decade switches per image | 400 |
| ● Number of signal lamps per project | 400 |
| — Signal lamps per image | 400 |
| Attributes for dynamic objects | |
| ● Color change | Yes |
| ● X/Y movement | Yes |
| ● Hide | Yes |
| ● Angle of rotation | No |
| Lists | |
| ● Number of text lists per project | 500 |
| ● Number of text lists per image | 400 |
| ● Number of entries per text list | 256 |
| ● Number of graphics lists per project | 500 |
| ● Number of graphic lists per image | 400 |
| ● Number of entries per graphics list | 256 |
| Archiving | |
| ● Number of archives per device | 50 |
| ● Number of measuring points per project | 50 |
| ● Number of entries per archive | 50 000 |
| ● Message archive | Yes |
| ● Process value archive | Yes |
| ● Archiving methods | Sequential log, circular log, alarm log, process value archive |
| — Sequential archive | Yes |
| — Short-term archive | Yes |
| ● Memory location | PC card, CF card, Ethernet |
| — PC card | Yes |
| — CF card | Yes |
| — USB memory | No |
| — Ethernet | Yes |
| ● Data storage format | CSV file, readable, e.g. with MS Excel, MS Access |
| — CSV | Yes |
| — TXT | No |
| ● external evaluation | readable, e.g. with MS Excel, MS Access, etc. |
| ● Size of archive | depending on free memory on ext. card/stick or on free hard disk space via network drive |
| ● Online evaluation | via trends |
| — using trend curves | Yes |
| Filters | |
| ● cyclic | Yes |
| ● Tolerance | Yes |
| ● Change | Yes |
| Security | |
| ● Number of user groups | 50 |
| ● Number of user rights | 32 |
| ● Password export/import | Yes |
| Data carrier support | |
| ● PC card | Yes |
| ● CF card | Yes |
| ● Diskette drive | No |
| ● Hard disk | No |
| ● CD-ROM | No |
| Logging through printer | |
| ● Recording/Printing | Alarms, report (shift report), color print, hardcopy |
| Transfer (upload/download) | |
| ● Transfer of configuration | MPI/PROFIBUS DP, serial, USB, Ethernet, by means of external storage medium, automatic transfer recognition |
| Process coupling | |
| ● Connection to controller | S5, S7-200, S7- 300/400, TI 505, Win AC, PC (TCP/IP), SINUMERIK, SIMOTION, Allen Bradley (DF1), Allen Bradley (DF485), Mitsubishi (FX), Telemecanique (ADJUST), OMRON (LINK/Multilink), Modicon (Modbus), for further non-Siemens drivers, see section on "System interfaces" |
| ● S7-200 | Yes |
| — PPI (point-to-point) | Yes |
| — PPI network | Yes |
| — MPI | Yes |
| — PROFIBUS DP | Yes |
| ● S7-300/400 | Yes |
| — MPI | Yes |
| — PROFIBUS DP | Yes |
| — PROFINET | Yes |
| ● S5 | Yes |
| — serial | Yes |
| — PROFIBUS DP | Yes |
| ● TI 505 | Yes |
| ● Allen Bradley (DF1) | Yes |
| ● Allen Bradley (DF485) | Yes |
| ● Mitsubishi (FX) | Yes |
| ● Mitsubishi (MP4) | Yes |
| ● Telemecanique (ADJUST) | Yes |
| ● Telemecanique (Uni-Telway) | Yes |
| ● OMRON (LINK/Multilink) | Yes |
| ● Modicon (Modbus) | Yes |
| ● GE-Fanuc (SNP) | Yes |
| Functions | |
| ● Key repeat | No |
| ● TAB sequence | Yes |
| ● Calculating functions | Yes |
| ● Animate | Yes |
| ● Menu tree editor | No |
| ● Unit switchover | No |
| Service tools/configuration aids | |
| ● Clean screen | Yes |
| ● Touch calibration | Yes |
| ● Backup/Restore manually | Yes |
| ● Simulation | Yes |
| ● Device switchover | Yes |
| ● Delta transfer | Yes |
| ● Monitoring function for battery and memory | Yes |
| ● Trace (operation archive) | No |
| Expandability/openness | |
| ● Open Platform Program | Yes |
| Peripherals/Options | |
| Peripherals | Printer, barcode reader |
| SIMATIC HMI MM memory card: Multi Media Card | No |
| SIMATIC HMI SD memory card: Secure Digital memory card | No |
| USB memory | No |
| Dimensions | |
| Width of the housing front | 335 mm |
| Height of housing front | 275 mm |
| Overall depth | 59 mm |
| Weights | |
| Weight (without packaging) | 4.5 kg |
| Fault description | Possible solution |
|---|---|
| Why does the MP370 touchscreen respond inaccurately or not at all? | After an OS update or project transfer, the touchscreen should be recalibrated via Control Panel > OP > Touch. Siemens explicitly describes touchscreen calibration as a required step for touch panels, and the same procedure is also confirmed for the MP370 in specialist user forums. If the touch points are significantly offset, perform the touchscreen calibration first and then verify operation again. If the issue persists, the touchscreen hardware itself should be checked for faults. |
| Why is ProSave unable to establish a connection to the MP370? | First, ensure that MP370 Touch is selected as the correct device type in ProSave, that the appropriate connection method has been configured, and that the panel has been placed into Transfer Mode. Siemens recommends checking the transfer mode, physical cabling and communication settings both in ProSave and on the panel whenever communication issues occur. Specialist forum discussions relating to MP370 connection problems identify these same points as the primary troubleshooting steps. |
| Why does the MP370 remain on a grey start screen or a black screen after an update? | In this situation, the OS update should be repeated using the correct image path. If the panel does not boot correctly, it may be necessary to perform a factory reset or a boot recovery via ProSave. Siemens describes this procedure using ProTool/ProSave together with the IF2 RS232 serial connection. Similar symptoms following an interrupted update have also been reported and discussed by MP370 users in specialist forums. If the interruption was caused by a failed or incomplete update process, restoring the operating system is often the most effective solution. |
| Why does the project transfer fail, or why is the expected transfer option missing after an update? | In many cases, the root cause is an incorrect image path or an incompatible OS or engineering software version. Specialist forum discussions relating to the MP370 specifically highlight the importance of using the correct image path, while Siemens also emphasises in its update documentation that both the image file and the transfer settings must be configured correctly. Therefore, before taking any further action, verify the software version, image file and connection type to ensure they are fully compatible with the target panel. |
Is 6AV6545-0DA10-0AX0 still available or has it already been discontinued?
The device belongs to the discontinued MP370 product generation. Siemens classified the MP370 series as a phase-out product as early as 2008, while the specific panel continues to be listed as a spare part. The EICHLER product page additionally specifies an EOP (End of Production) status effective from 01 August 2008. For operators, this primarily means that purchasing new units is no longer the standard approach. Instead, long-term availability is typically maintained through repair services, exchange units, used devices and strategic stockholding.
Which engineering software is required for the MP370 12" Touch?
The product documentation specifies ProTool from Version 5.2 SP3 or WinCC flexible Standard from Version 2004 onwards for engineering and project configuration. This is particularly important for service activities, data backup procedures and migration planning, as many legacy systems still operate on exactly this engineering platform. Anyone intending to source a replacement device or restore an existing project should first verify which project version is currently available and whether the corresponding engineering environment is still accessible.
Which communication and service interfaces are available on the panel?
The MP370 12" Touch provides 1 × TTY, 2 × RS232, 1 × RS422, 1 × RS485, 1 × Ethernet RJ45 and 1 × USB, as well as PC card and CF card slots. For maintenance personnel, these interfaces are important because they define the available options for project transfer, diagnostics, data backup and integration into legacy systems. In existing machines that combine both older and newer communication technologies, this broad range of interfaces is particularly advantageous because it allows legacy communication structures to remain in operation.
Is there a manufacturer-recommended successor for the 6AV6545-0DA10-0AX0?
Within Siemens support documentation, the MP377 12" Touch was initially identified as the direct successor platform, while the TP1500 Comfort was later referenced as the next-generation replacement concept. In practice, however, these alternatives should not be regarded as simple plug-and-play replacements. Due to the different platform generations, software environments and migration requirements, factors such as project conversion, mounting cut-out dimensions, communication interfaces and commissioning effort must be carefully assessed before a replacement is implemented.
Which power supply and environmental conditions are important for operation?
The panel requires a 24 V DC power supply, has a typical power consumption of 28 W, and is designed to operate within an ambient temperature range of 0 to 50 °C. It is rated IP65 on the front panel and IP20 on the rear. For control cabinet and machine-building applications, this means that the panel is suitable for traditional industrial installation environments, provided that the thermal conditions, vertical mounting orientation and the maximum permissible 35° installation angle without forced ventilation are observed. Before replacing the panel, it is therefore advisable to confirm that the actual environmental conditions of the system still fall within these specified limits.
When is repair more sensible than immediate migration?
A repair is usually the preferred option when the existing project must remain operational, the machine needs to be returned to service quickly, and major modifications to the visualisation, engineering environment and commissioning process should be avoided. For this device, EICHLER offers repair services, exchange units and used-device procurement with typical turnaround times of 1–3 days. The repair service includes technical cleaning, preventive maintenance, comprehensive functional testing and a minimum 24-month warranty. Where long-term obsolescence risks exist, additional Life Cycle Management measures can help transform an isolated repair requirement into a structured and sustainable supply strategy.