SIEMENS 6AV6545-0DA10-0AX0

  • SIEMENS | HMI | Touch Panels

  • EICHLER-art.no.: K0116927
  • EAN: 4025515066668

Product description

SIMATIC Multi Panel MP 370 12" color TFT display, Touch Windows CE 3.0 configurable with ProTool From Version V5.2+SP3

Services for SIEMENS 6AV6545-0DA10-0AX0

Repair

1-3 days

from 1.670,61 €

to 3.007,10 €

per pc. 159,00 €

Replacement

1-3 days

10+ Pcs.

3.444,30 €

per pc. 159,00 €

3.444,30 € *

Please enter an offer recipient here.


Used

1-3 days

10+ Pcs.

3.827,00 €

per pc. 159,00 €

3.827,00 € *

Please enter an offer recipient here.


New

Delivery information
Export identifier AL: ECCN:
Net weight 3.6
Quantity 1 Stück
Packaging quantity 1
Additional product information
Product status EOP: 2008-08-01
EAN 4025515066668
UPC /
Static lot number 85371098
List indicator /
Product group /
Country of origin DE
Compliance with the substance restrictions according to RoHS directive Since: /
Product classifications Version Classification
eClass 4 /
eClass 5.1 /
eClass 6.0 /
ETIM 3 /
ETIM 4 /
ETIM 5 /

Attribute Value
Customer-specific configuration No
Display
Design of display TFT, 256 colors
Screen diagonal 12.1 in
Resolution (pixels)
● Horizontal image resolution 800 Pixel
● Vertical image resolution 600 Pixel
Backlighting
● MTBF backlighting (at 25 °C) 50 000 h
Control elements
Control elements Touch screen
Keyboard fonts
● Membrane keyboard No
— user-definable label membrane keys No
● Function keys
— Number of function keys 0
● Numeric keyboard Yes
● alphanumeric keyboard Yes
● hexadecimal keyboard Yes
● Multi-key operation No
— Number of multi-key operations 0
Touch operation
● Design as touch screen Yes; analog, resistive
Connection type
● Type of connection for mouse/keyboard/barcode reader USB / USB / USB
Special operator controls
● Illuminated pushbutton Yes
Installation type/mounting
Mounting position vertical
maximum permissible angle of inclination without external ventilation 35°
Supply voltage
Type of supply voltage DC
UPS connectable (serial) Yes
Input current
Current consumption (rated value) 1.15 A
Starting current inrush I²t 0.5 A²·s
Power
Active power input, typ. 28 W
Processor
Processor type MIPS
Memory
Type of memory Flash / RAM
Memory available for user data 7 168 kbyte
Battery
Backup battery
● Backup battery (optional) Yes; optional 3.6 V
● Backup time, min. 3 y
Type of output
Info LED No
Power LED No
Error LED No
Time of day
Clock
● Type Hardware clock, battery backup, synchronizable
● retentive Yes; yes, via optional battery
● synchronizable Yes
Interfaces
Interfaces/bus type 1x TTY, 2x RS 232, 1x RS 422, 1x RS 485, 1x Ethernet (RJ45) (max. 12 Mbit/s)
USB port Yes; 1x USB
PC card slot 1x PC card slot
CF card slot 1x CF card slot
Degree and class of protection
IP (at the front) IP65
IP (rear) IP20
Standards, approvals, certificates
Certificate of suitability CE, FM Class I Div. 2, cULus, EX Zone 2/22
Ambient conditions
Ambient temperature during operation
● min. 0 °C
● max. 50 °C
Ambient temperature during storage/transportation
● min. -20 °C
● max. 60 °C
Relative humidity
● Operation, max. 85 %
Operating systems
pre-installed operating system Windows CE
Configuration
Configuration software
● Configuration tool ProTool Version 5.2 SP 3 or higher, or WinCC flexible Standard Version 2004 or higher (to be ordered separately)
Languages
Online languages
● Number of online/runtime languages 5
Project languages
● Languages per project 32
Functionality under WinCC (TIA Portal)
Libraries Yes
Number of Visual Basic Scripts
● Debugging in the simulator No
Task planner Yes
Help system Yes
● Number of characters per info text 70
● Number of tooltips 0
Message system
● Number of alarm classes 32
● Number of messages 4 000
● Bit messages Yes
— Number of bit messages 4 000
● Analog messages Yes
— Number of analog messages 4 000
● Telegram message procedure Alarm S Yes
● System messages HMI Yes
● System messages PLC Yes
● System messages, other (SIMATIC S7, Sinumerik, Simotion, etc.) Yes
● Lines 1
● Number of characters per message 80
● Number of process values per message 8
● Acknowledgment groups Yes
● Message indicator Yes
● acoustic feedback No
● First/last value Yes
Recipe management
● Number of recipes 500
● Data records per recipe 1 000
● Entries per data record 1 000
● Recipe memory 128 KB integrated Flash, expandable
Variables
● Number of variables per device 2 048
● Number of variables per screen 400
● Number of variables 2 000
● Initial values 2 048
● Type Date & Time 2 048
● Limit values Yes
● Multiplexing Yes
● Structures Yes
Images
● Number of configurable images 500
● Permanent window/default Yes
● Start screen configurable Yes
● Image selection by PLC Yes
● Image number in the PLC Yes
Image objects
● Text objects 30 000 text elements
● Number of I/O fields per image 400
● Number of date/time fields 400
● Index of screen context No
● Return Yes
● Graphics object Bit maps, icons, vector graphics
— Icons 2 000
— Icon (full screen) 0
Complex image objects
● Status/control With SIMATIC S7
● dynamic objects Diagrams, bar graphs, sliders, analog display, invisible buttons
— Number of objects per project 2 000
— Number of curve diagrams per image 20
● Methods Trend / profile
● Bar graphs
— Number of bars per chart 20
● Sliders
— Number of slides per image 20
● Pointer instruments
— Number of analog indicators per image 20
● Limit value lines Yes
● Number of alphanumerical fields 300
— alphanumeric fields per image 400
● Number of numerical fields 2 048
— numerical fields per image 400
● Number of password fields 2 048
● Number of visible switches per project 400
— visible switches per image 400
— hidden switches per image 400
● Number of status switches per project 400
— Number of status switches per image 400
● Number of selector switches per project 400
— Selector switches per image 400
● Number of decade switches per project 400
— Decade switches per image 400
● Number of signal lamps per project 400
— Signal lamps per image 400
Attributes for dynamic objects
● Color change Yes
● X/Y movement Yes
● Hide Yes
● Angle of rotation No
Lists
● Number of text lists per project 500
● Number of text lists per image 400
● Number of entries per text list 256
● Number of graphics lists per project 500
● Number of graphic lists per image 400
● Number of entries per graphics list 256
Archiving
● Number of archives per device 50
● Number of measuring points per project 50
● Number of entries per archive 50 000
● Message archive Yes
● Process value archive Yes
● Archiving methods Sequential log, circular log, alarm log, process value archive
— Sequential archive Yes
— Short-term archive Yes
● Memory location PC card, CF card, Ethernet
— PC card Yes
— CF card Yes
— USB memory No
— Ethernet Yes
● Data storage format CSV file, readable, e.g. with MS Excel, MS Access
— CSV Yes
— TXT No
● external evaluation readable, e.g. with MS Excel, MS Access, etc.
● Size of archive depending on free memory on ext. card/stick or on free hard disk space via network drive
● Online evaluation via trends
— using trend curves Yes
Filters
● cyclic Yes
● Tolerance Yes
● Change Yes
Security
● Number of user groups 50
● Number of user rights 32
● Password export/import Yes
Data carrier support
● PC card Yes
● CF card Yes
● Diskette drive No
● Hard disk No
● CD-ROM No
Logging through printer
● Recording/Printing Alarms, report (shift report), color print, hardcopy
Transfer (upload/download)
● Transfer of configuration MPI/PROFIBUS DP, serial, USB, Ethernet, by means of external storage medium, automatic transfer recognition
Process coupling
● Connection to controller S5, S7-200, S7- 300/400, TI 505, Win AC, PC (TCP/IP), SINUMERIK, SIMOTION, Allen Bradley (DF1), Allen Bradley (DF485), Mitsubishi (FX), Telemecanique (ADJUST), OMRON (LINK/Multilink), Modicon (Modbus), for further non-Siemens drivers, see section on "System interfaces"
● S7-200 Yes
— PPI (point-to-point) Yes
— PPI network Yes
— MPI Yes
— PROFIBUS DP Yes
● S7-300/400 Yes
— MPI Yes
— PROFIBUS DP Yes
— PROFINET Yes
● S5 Yes
— serial Yes
— PROFIBUS DP Yes
● TI 505 Yes
● Allen Bradley (DF1) Yes
● Allen Bradley (DF485) Yes
● Mitsubishi (FX) Yes
● Mitsubishi (MP4) Yes
● Telemecanique (ADJUST) Yes
● Telemecanique (Uni-Telway) Yes
● OMRON (LINK/Multilink) Yes
● Modicon (Modbus) Yes
● GE-Fanuc (SNP) Yes
Functions
● Key repeat No
● TAB sequence Yes
● Calculating functions Yes
● Animate Yes
● Menu tree editor No
● Unit switchover No
Service tools/configuration aids
● Clean screen Yes
● Touch calibration Yes
● Backup/Restore manually Yes
● Simulation Yes
● Device switchover Yes
● Delta transfer Yes
● Monitoring function for battery and memory Yes
● Trace (operation archive) No
Expandability/openness
● Open Platform Program Yes
Peripherals/Options
Peripherals Printer, barcode reader
SIMATIC HMI MM memory card: Multi Media Card No
SIMATIC HMI SD memory card: Secure Digital memory card No
USB memory No
Dimensions
Width of the housing front 335 mm
Height of housing front 275 mm
Overall depth 59 mm
Weights
Weight (without packaging) 4.5 kg

Important documents

Repair accompanying note

Download the repair accompanying note as a PDF, or use the digital repair registration and send your defective modules to the EICHLER Service Centre for repair.

Laughing Eichler technician points to green PDF with special sale of automation technology

Quality & warranty

Outstanding service quality with every handle

Two Eichler technicians high-five each other after a successful repair

Your shopping basket

Loading shopping basket