SIEMENS 6AV6545-0DA10-0AX0

  • EICHLER-art.no.: K0116927
  • EAN: 4025515066668

Product description

SIMATIC Multi Panel MP 370 12" color TFT display, Touch Windows CE 3.0 configurable with ProTool From Version V5.2+SP3

Services for SIEMENS 6AV6545-0DA10-0AX0

Repair

1-3 days

from 1.747,93 €

to 3.146,27 €

per pc. 159,00 €

Replacement

1-3 days

10+ Pcs.

3.444,30 €

per pc. 159,00 €

3.444,30 € *

Please enter an offer recipient here.


Used

1-3 days

10+ Pcs.

3.827,00 €

per pc. 159,00 €

3.827,00 € *

Please enter an offer recipient here.


New

Delivery information
Export identifier AL: ECCN:
Net weight 3.6
Quantity 1 Stück
Packaging quantity 1
Additional product information
Product status EOP: 2008-08-01
EAN 4025515066668
UPC /
Static lot number 85371098
List indicator /
Product group /
Country of origin DE
Compliance with the substance restrictions according to RoHS directive Since: /
Product classifications Version Classification
eClass 4 /
eClass 5.1 /
eClass 6.0 /
ETIM 3 /
ETIM 4 /
ETIM 5 /

What is 6AV6545-0DA10-0AX0 and where is it used?

The 6AV6545-0DA10-0AX0 is a SIEMENS SIMATIC Multi Panel MP370 12" Touch. It is an industrial HMI operator panel featuring a 12.1-inch colour TFT display, touchscreen operation, Windows CE 3.0, and engineering support via ProTool from Version 5.2 SP3 or WinCC flexible Standard from Version 2004 onwards. The panel is typically used for machine and system operation in existing installations, where visualisation, alarms, recipes and diagnostic functions continue to run on an established MP370 platform. For maintenance personnel, the exact part number is particularly important because it enables the correct identification of the appropriate panel for fault diagnosis, spare-part identification, repair approval and replacement procurement.

Overview of the key technical specifications and their significance

The panel is equipped with a resistive analogue touchscreen, a resolution of 800 × 600 pixels, a 24 V DC power supply, a typical power consumption of 28 W, and a nominal current consumption of 1.15 A. Additional features relevant for industrial applications include IP65 protection on the front panel, IP20 protection on the rear, an operating temperature range of 0 to 50 °C, and a wide range of interfaces including TTY, 2 × RS232, RS422, RS485, Ethernet RJ45 and USB, as well as PC card and CF card slots. For operators, these specifications primarily mean excellent suitability for traditional control cabinet and machine-front installations, compatibility with legacy communication environments, and continued access to established service options for older systems. The optional 3.6 V backup battery and support for a serial UPS connection provide additional protection for data and operating states in critical applications.

Product status, life-cycle status and obsolescence

The MP370 12" Touch is listed by Siemens as a spare part, while the EICHLER product page additionally specifies an EOP (End of Production) status effective from 01 August 2008. Siemens already classified the MP370 series as a phase-out product in 2008, providing a clear indication of its obsolete status. For operators, this means that purchasing new units through traditional manufacturer channels is becoming increasingly difficult, while repair services, exchange units, used-device procurement and strategic stockholding are gaining importance. Within Siemens support documentation, the MP377 12" Touch was initially identified as the successor platform, with the TP1500 Comfort subsequently referenced as a later-generation successor. In practice, however, these alternatives should not be regarded as direct one-to-one replacements. Any migration must be carefully evaluated with regard to project migration, installation requirements, communication interfaces and commissioning procedures.

Available EICHLER services and when they are relevant

For this assembly, EICHLER offers several practical options, including repair services, exchange units, used-device procurement and new-device enquiries. According to the product page, repair, exchange and used-device options are each available with typical turnaround or delivery times of 1–3 days. For repairs, EICHLER additionally provides technical cleaning, preventive maintenance, comprehensive functional testing and a minimum 24-month warranty. For obsolete HMI assemblies in particular, these services are highly valuable for maintenance and purchasing departments because downtime can often be resolved more quickly through repair or replacement than through an immediate migration project. In addition, Life Cycle Management services help address obsolescence challenges through asset assessments, risk evaluations and supply strategies, enabling operators to systematically reduce the risk of supply shortages for ageing operator panels.

Attribute Value
Customer-specific configuration No
Display
Design of display TFT, 256 colors
Screen diagonal 12.1 in
Resolution (pixels)
● Horizontal image resolution 800 Pixel
● Vertical image resolution 600 Pixel
Backlighting
● MTBF backlighting (at 25 °C) 50 000 h
Control elements
Control elements Touch screen
Keyboard fonts
● Membrane keyboard No
— user-definable label membrane keys No
● Function keys
— Number of function keys 0
● Numeric keyboard Yes
● alphanumeric keyboard Yes
● hexadecimal keyboard Yes
● Multi-key operation No
— Number of multi-key operations 0
Touch operation
● Design as touch screen Yes; analog, resistive
Connection type
● Type of connection for mouse/keyboard/barcode reader USB / USB / USB
Special operator controls
● Illuminated pushbutton Yes
Installation type/mounting
Mounting position vertical
maximum permissible angle of inclination without external ventilation 35°
Supply voltage
Type of supply voltage DC
UPS connectable (serial) Yes
Input current
Current consumption (rated value) 1.15 A
Starting current inrush I²t 0.5 A²·s
Power
Active power input, typ. 28 W
Processor
Processor type MIPS
Memory
Type of memory Flash / RAM
Memory available for user data 7 168 kbyte
Battery
Backup battery
● Backup battery (optional) Yes; optional 3.6 V
● Backup time, min. 3 y
Type of output
Info LED No
Power LED No
Error LED No
Time of day
Clock
● Type Hardware clock, battery backup, synchronizable
● retentive Yes; yes, via optional battery
● synchronizable Yes
Interfaces
Interfaces/bus type 1x TTY, 2x RS 232, 1x RS 422, 1x RS 485, 1x Ethernet (RJ45) (max. 12 Mbit/s)
USB port Yes; 1x USB
PC card slot 1x PC card slot
CF card slot 1x CF card slot
Degree and class of protection
IP (at the front) IP65
IP (rear) IP20
Standards, approvals, certificates
Certificate of suitability CE, FM Class I Div. 2, cULus, EX Zone 2/22
Ambient conditions
Ambient temperature during operation
● min. 0 °C
● max. 50 °C
Ambient temperature during storage/transportation
● min. -20 °C
● max. 60 °C
Relative humidity
● Operation, max. 85 %
Operating systems
pre-installed operating system Windows CE
Configuration
Configuration software
● Configuration tool ProTool Version 5.2 SP 3 or higher, or WinCC flexible Standard Version 2004 or higher (to be ordered separately)
Languages
Online languages
● Number of online/runtime languages 5
Project languages
● Languages per project 32
Functionality under WinCC (TIA Portal)
Libraries Yes
Number of Visual Basic Scripts
● Debugging in the simulator No
Task planner Yes
Help system Yes
● Number of characters per info text 70
● Number of tooltips 0
Message system
● Number of alarm classes 32
● Number of messages 4 000
● Bit messages Yes
— Number of bit messages 4 000
● Analog messages Yes
— Number of analog messages 4 000
● Telegram message procedure Alarm S Yes
● System messages HMI Yes
● System messages PLC Yes
● System messages, other (SIMATIC S7, Sinumerik, Simotion, etc.) Yes
● Lines 1
● Number of characters per message 80
● Number of process values per message 8
● Acknowledgment groups Yes
● Message indicator Yes
● acoustic feedback No
● First/last value Yes
Recipe management
● Number of recipes 500
● Data records per recipe 1 000
● Entries per data record 1 000
● Recipe memory 128 KB integrated Flash, expandable
Variables
● Number of variables per device 2 048
● Number of variables per screen 400
● Number of variables 2 000
● Initial values 2 048
● Type Date & Time 2 048
● Limit values Yes
● Multiplexing Yes
● Structures Yes
Images
● Number of configurable images 500
● Permanent window/default Yes
● Start screen configurable Yes
● Image selection by PLC Yes
● Image number in the PLC Yes
Image objects
● Text objects 30 000 text elements
● Number of I/O fields per image 400
● Number of date/time fields 400
● Index of screen context No
● Return Yes
● Graphics object Bit maps, icons, vector graphics
— Icons 2 000
— Icon (full screen) 0
Complex image objects
● Status/control With SIMATIC S7
● dynamic objects Diagrams, bar graphs, sliders, analog display, invisible buttons
— Number of objects per project 2 000
— Number of curve diagrams per image 20
● Methods Trend / profile
● Bar graphs
— Number of bars per chart 20
● Sliders
— Number of slides per image 20
● Pointer instruments
— Number of analog indicators per image 20
● Limit value lines Yes
● Number of alphanumerical fields 300
— alphanumeric fields per image 400
● Number of numerical fields 2 048
— numerical fields per image 400
● Number of password fields 2 048
● Number of visible switches per project 400
— visible switches per image 400
— hidden switches per image 400
● Number of status switches per project 400
— Number of status switches per image 400
● Number of selector switches per project 400
— Selector switches per image 400
● Number of decade switches per project 400
— Decade switches per image 400
● Number of signal lamps per project 400
— Signal lamps per image 400
Attributes for dynamic objects
● Color change Yes
● X/Y movement Yes
● Hide Yes
● Angle of rotation No
Lists
● Number of text lists per project 500
● Number of text lists per image 400
● Number of entries per text list 256
● Number of graphics lists per project 500
● Number of graphic lists per image 400
● Number of entries per graphics list 256
Archiving
● Number of archives per device 50
● Number of measuring points per project 50
● Number of entries per archive 50 000
● Message archive Yes
● Process value archive Yes
● Archiving methods Sequential log, circular log, alarm log, process value archive
— Sequential archive Yes
— Short-term archive Yes
● Memory location PC card, CF card, Ethernet
— PC card Yes
— CF card Yes
— USB memory No
— Ethernet Yes
● Data storage format CSV file, readable, e.g. with MS Excel, MS Access
— CSV Yes
— TXT No
● external evaluation readable, e.g. with MS Excel, MS Access, etc.
● Size of archive depending on free memory on ext. card/stick or on free hard disk space via network drive
● Online evaluation via trends
— using trend curves Yes
Filters
● cyclic Yes
● Tolerance Yes
● Change Yes
Security
● Number of user groups 50
● Number of user rights 32
● Password export/import Yes
Data carrier support
● PC card Yes
● CF card Yes
● Diskette drive No
● Hard disk No
● CD-ROM No
Logging through printer
● Recording/Printing Alarms, report (shift report), color print, hardcopy
Transfer (upload/download)
● Transfer of configuration MPI/PROFIBUS DP, serial, USB, Ethernet, by means of external storage medium, automatic transfer recognition
Process coupling
● Connection to controller S5, S7-200, S7- 300/400, TI 505, Win AC, PC (TCP/IP), SINUMERIK, SIMOTION, Allen Bradley (DF1), Allen Bradley (DF485), Mitsubishi (FX), Telemecanique (ADJUST), OMRON (LINK/Multilink), Modicon (Modbus), for further non-Siemens drivers, see section on "System interfaces"
● S7-200 Yes
— PPI (point-to-point) Yes
— PPI network Yes
— MPI Yes
— PROFIBUS DP Yes
● S7-300/400 Yes
— MPI Yes
— PROFIBUS DP Yes
— PROFINET Yes
● S5 Yes
— serial Yes
— PROFIBUS DP Yes
● TI 505 Yes
● Allen Bradley (DF1) Yes
● Allen Bradley (DF485) Yes
● Mitsubishi (FX) Yes
● Mitsubishi (MP4) Yes
● Telemecanique (ADJUST) Yes
● Telemecanique (Uni-Telway) Yes
● OMRON (LINK/Multilink) Yes
● Modicon (Modbus) Yes
● GE-Fanuc (SNP) Yes
Functions
● Key repeat No
● TAB sequence Yes
● Calculating functions Yes
● Animate Yes
● Menu tree editor No
● Unit switchover No
Service tools/configuration aids
● Clean screen Yes
● Touch calibration Yes
● Backup/Restore manually Yes
● Simulation Yes
● Device switchover Yes
● Delta transfer Yes
● Monitoring function for battery and memory Yes
● Trace (operation archive) No
Expandability/openness
● Open Platform Program Yes
Peripherals/Options
Peripherals Printer, barcode reader
SIMATIC HMI MM memory card: Multi Media Card No
SIMATIC HMI SD memory card: Secure Digital memory card No
USB memory No
Dimensions
Width of the housing front 335 mm
Height of housing front 275 mm
Overall depth 59 mm
Weights
Weight (without packaging) 4.5 kg

Fault description Possible solution
Why does the MP370 touchscreen respond inaccurately or not at all? After an OS update or project transfer, the touchscreen should be recalibrated via Control Panel > OP > Touch. Siemens explicitly describes touchscreen calibration as a required step for touch panels, and the same procedure is also confirmed for the MP370 in specialist user forums. If the touch points are significantly offset, perform the touchscreen calibration first and then verify operation again. If the issue persists, the touchscreen hardware itself should be checked for faults.
Why is ProSave unable to establish a connection to the MP370? First, ensure that MP370 Touch is selected as the correct device type in ProSave, that the appropriate connection method has been configured, and that the panel has been placed into Transfer Mode. Siemens recommends checking the transfer mode, physical cabling and communication settings both in ProSave and on the panel whenever communication issues occur. Specialist forum discussions relating to MP370 connection problems identify these same points as the primary troubleshooting steps.
Why does the MP370 remain on a grey start screen or a black screen after an update? In this situation, the OS update should be repeated using the correct image path. If the panel does not boot correctly, it may be necessary to perform a factory reset or a boot recovery via ProSave. Siemens describes this procedure using ProTool/ProSave together with the IF2 RS232 serial connection. Similar symptoms following an interrupted update have also been reported and discussed by MP370 users in specialist forums. If the interruption was caused by a failed or incomplete update process, restoring the operating system is often the most effective solution.
Why does the project transfer fail, or why is the expected transfer option missing after an update? In many cases, the root cause is an incorrect image path or an incompatible OS or engineering software version. Specialist forum discussions relating to the MP370 specifically highlight the importance of using the correct image path, while Siemens also emphasises in its update documentation that both the image file and the transfer settings must be configured correctly. Therefore, before taking any further action, verify the software version, image file and connection type to ensure they are fully compatible with the target panel.

Is 6AV6545-0DA10-0AX0 still available or has it already been discontinued?

The device belongs to the discontinued MP370 product generation. Siemens classified the MP370 series as a phase-out product as early as 2008, while the specific panel continues to be listed as a spare part. The EICHLER product page additionally specifies an EOP (End of Production) status effective from 01 August 2008. For operators, this primarily means that purchasing new units is no longer the standard approach. Instead, long-term availability is typically maintained through repair services, exchange units, used devices and strategic stockholding.

Which engineering software is required for the MP370 12" Touch?

The product documentation specifies ProTool from Version 5.2 SP3 or WinCC flexible Standard from Version 2004 onwards for engineering and project configuration. This is particularly important for service activities, data backup procedures and migration planning, as many legacy systems still operate on exactly this engineering platform. Anyone intending to source a replacement device or restore an existing project should first verify which project version is currently available and whether the corresponding engineering environment is still accessible.

Which communication and service interfaces are available on the panel?

The MP370 12" Touch provides 1 × TTY, 2 × RS232, 1 × RS422, 1 × RS485, 1 × Ethernet RJ45 and 1 × USB, as well as PC card and CF card slots. For maintenance personnel, these interfaces are important because they define the available options for project transfer, diagnostics, data backup and integration into legacy systems. In existing machines that combine both older and newer communication technologies, this broad range of interfaces is particularly advantageous because it allows legacy communication structures to remain in operation.

Is there a manufacturer-recommended successor for the 6AV6545-0DA10-0AX0?

Within Siemens support documentation, the MP377 12" Touch was initially identified as the direct successor platform, while the TP1500 Comfort was later referenced as the next-generation replacement concept. In practice, however, these alternatives should not be regarded as simple plug-and-play replacements. Due to the different platform generations, software environments and migration requirements, factors such as project conversion, mounting cut-out dimensions, communication interfaces and commissioning effort must be carefully assessed before a replacement is implemented.

Which power supply and environmental conditions are important for operation?

The panel requires a 24 V DC power supply, has a typical power consumption of 28 W, and is designed to operate within an ambient temperature range of 0 to 50 °C. It is rated IP65 on the front panel and IP20 on the rear. For control cabinet and machine-building applications, this means that the panel is suitable for traditional industrial installation environments, provided that the thermal conditions, vertical mounting orientation and the maximum permissible 35° installation angle without forced ventilation are observed. Before replacing the panel, it is therefore advisable to confirm that the actual environmental conditions of the system still fall within these specified limits.

When is repair more sensible than immediate migration?

A repair is usually the preferred option when the existing project must remain operational, the machine needs to be returned to service quickly, and major modifications to the visualisation, engineering environment and commissioning process should be avoided. For this device, EICHLER offers repair services, exchange units and used-device procurement with typical turnaround times of 1–3 days. The repair service includes technical cleaning, preventive maintenance, comprehensive functional testing and a minimum 24-month warranty. Where long-term obsolescence risks exist, additional Life Cycle Management measures can help transform an isolated repair requirement into a structured and sustainable supply strategy.

Important documents

Repair accompanying note

Download the repair accompanying note as a PDF, or use the digital repair registration and send your defective modules to the EICHLER Service Centre for repair.

Laughing Eichler technician points to green PDF with special sale of automation technology

Your shopping basket

Loading shopping basket