SIMATIC Touch Panel TP 170B mono blue mode STN display MPI/PROFIBUS DP interface Printer/RS232 interface Slot for CF card configurable with ProTool/Lite as of Version V5.2+SP2

Services for SIEMENS 6AV6545-0BB15-2AX0

Repair

1-3 days

from 1.225,88 €

to 2.206,58 €

per pc. 159,00 €

Replacement

1-3 days

10+ Pcs.

1.514,70 €

per pc. 159,00 €

1.514,70 € *

Please enter an offer recipient here.


Used

1-3 days

10+ Pcs.

1.683,00 €

per pc. 159,00 €

1.683,00 € *

Please enter an offer recipient here.


New

1-3 days

1 Pcs.

2.714,00 €

2.714,00 € *

Please enter an offer recipient here.


Delivery information
Export identifier AL: ECCN:
Net weight 0.7
Quantity 1 Stück
Packaging quantity 1
Additional product information
Product status EOP: 2008-04-01
EAN 4025515066125
UPC /
Static lot number 85371095
List indicator /
Product group /
Country of origin /
Compliance with the substance restrictions according to RoHS directive Since: /
Product classifications Version Classification
eClass 4 /
eClass 5.1 /
eClass 6.0 /
ETIM 3 /
ETIM 4 /
ETIM 5 /

What is 6AV6545-0BB15-2AX0 and where is it used?

6AV6545-0BB15-2AX0 is a SIEMENS SIMATIC HMI TP 170B Mono touch panel designed for operating and monitoring machines and systems. The device features a 5.7-inch STN display with 4 blue-grey shades and is intended for classic HMI tasks such as entering setpoints, displaying alarms, visualising operating states and providing simple operator screens during production. Thanks to MPI/PROFIBUS-DP and additional serial interfaces, the panel is particularly suitable for existing installations where older SIMATIC architectures remain in operation. Typical applications include retrofit projects, spare-parts scenarios in maintenance environments and safeguarding production lines where the existing operating concept should be retained with minimal modification.

Overview of the key technical data and what they mean

The TP170B Mono features a resolution of 320 × 240 pixels, an analogue resistive touchscreen, a rated current consumption of 0.25 A and a typical power consumption of 6 W. For users, this means reliable operation for traditional machine screens, although it is not designed as a modern high-end graphics panel. Particularly important for replacement purposes are the available interfaces and bus systems: optional TTY, 2 × RS232, 1 × RS422, 1 × RS485 up to 12 Mbit/s, as well as a CF card slot. The front panel is rated IP65, while the rear is rated IP20. The device uses Windows CE as its pre-installed operating system and, according to the product data, can be engineered with ProTool/Lite from Version 5.2 SP1 or WinCC flexible Compact from Version 2004. Siemens documentation also specifies a 24 V DC power supply. For purchasing and technical departments, these factors are critical because they determine electrical compatibility, project retention and installation suitability.

Product status, life-cycle status and obsolescence

For 6AV6545-0BB15-2AX0, the EICHLER product page lists a product status of EOP: 2008-04-01. Siemens also identifies the device as a spare part in search results and indicates in product status notifications that the TP170 series has been discontinued. For operators, this means that the panel clearly falls into the category of obsolescence management and installed-base support. Anyone intending to continue operating a system with this operator panel should secure not only the part number but also the project status, interface configuration, image version and spare-parts strategy. Siemens references successor generations within later panel families for the discontinued TP170 range; however, a direct 1:1 drop-in replacement should not be assumed for this specific order number. Before replacement, project migration requirements, communication paths and software versions should always be verified.

Available EICHLER services and when they are relevant

For this panel, EICHLER offers repair, exchange, used equipment and new equipment as service options. The repair service is listed with a turnaround time of 1–3 days and includes technical cleaning, preventive maintenance, comprehensive functional testing and a minimum 24-month warranty. In addition, the shop information highlights up to 36 months warranty and guarantee, fully tested assemblies and 24/7 service. This is particularly relevant when production downtime is costly, migration is currently not feasible, or an original device is required at short notice. From a maintenance and purchasing perspective, these services provide a practical bridge between obsolescence and continued system availability: instead of relying on uncertain remaining stock, operational reliability can be maintained through repair, exchange or tested replacement units.

Attribute Value
Display
Design of display STN, 4 blue levels
Screen diagonal 5.7 in
Resolution (pixels)
● Horizontal image resolution 320 Pixel
● Vertical image resolution 240 Pixel
Backlighting
● MTBF backlighting (at 25 °C) 50 000 h
Control elements
Control elements Touch screen
Keyboard fonts
● Numeric keyboard Yes
● alphanumeric keyboard Yes
● hexadecimal keyboard Yes
● Multi-key operation No
Touch operation
● Design as touch screen Yes; analog, resistive
Connection type
● Type of connection for mouse/keyboard/barcode reader - / - / -
Installation type/mounting
Mounting position vertical
maximum permissible angle of inclination without external ventilation 35°
Input current
Current consumption (rated value) 0.25 A
Power
Active power input, typ. 6 W
Processor
Processor type RISC 32 bit, 66 MHz
Memory
Type of memory Flash / RAM
Memory available for user data 768 kbyte
Time of day
Clock
● Type Software clock, synchronizable, no battery backup
● retentive No
● synchronizable Yes
Interfaces
Interfaces/bus type TTY optional, 2x RS 232, 1x RS 422, 1x RS 485 (max. 12 Mbit/s)
CF card slot 1x CF card slot
Degree and class of protection
IP (at the front) IP65
IP (rear) IP20
Standards, approvals, certificates
Certificate of suitability CE, FM Class I Div. 2, UL, CSA
Ambient conditions
Ambient temperature during storage/transportation
● min. -20 °C
● max. 60 °C
Relative humidity
● Operation, max. 85 %
Operating systems
pre-installed operating system Windows CE
Configuration
Configuration software
● Configuration tool ProTool / Lite, Version 5.2 SP 1 or higher or WinCC flexible Compact Version 2004 or higher (to be ordered separately)
Languages
Online languages
● Number of online/runtime languages 5
Project languages
● Languages per project 32
Functionality under WinCC (TIA Portal)
Libraries Yes
Task planner Yes
Help system Yes
● Number of characters per info text 70
● Number of tooltips 0
Message system
● Number of alarm classes 32
● Number of messages 2 000
● Bit messages Yes
— Number of bit messages 2 000
● Analog messages Yes
— Number of analog messages 2 000
● Telegram message procedure Alarm S No
● System messages HMI Yes
● System messages PLC No
● System messages, other (SIMATIC S7, Sinumerik, Simotion, etc.) No
● Lines 1
● Number of characters per message 80
● Number of process values per message 8
● Acknowledgment groups
— Number of acknowledgement groups 99
● Message indicator Yes
● acoustic feedback No
● First/last value Yes
Recipe management
● Number of recipes 100
● Data records per recipe 200
● Entries per data record 200
● Recipe memory 32 KB integrated Flash, expandable
Variables
● Number of variables per device 1 000
● Number of variables per screen 50
● Number of variables 1 000
● Initial values 1 000
● Type Date & Time 1 000
● Limit values Yes
● Multiplexing Yes
● Structures No
Images
● Number of configurable images 100
● Permanent window/default Yes
● Start screen configurable Yes
● Image selection by PLC Yes
● Image number in the PLC Yes
Image objects
● Text objects 2 000 text elements
● Number of I/O fields per image 0
● Number of date/time fields 30
● Index of screen context No
● Return Yes
● Graphics object Bit maps, icons, icon (full-screen)
— Icons 500
— Icon (full screen) 50
Complex image objects
● Status/control Not possible
● dynamic objects Diagrams, bar graphs, invisible buttons
— Number of objects per project 500
— Number of curve diagrams per image 5
● Methods Trend
● Bar graphs
— Number of bars per chart 5
● Sliders
— Number of slides per image 0
● Pointer instruments
— Number of analog indicators per image 0
● Limit value lines Yes
● Number of alphanumerical fields 1 000
— alphanumeric fields per image 100
● Number of numerical fields 1 000
— numerical fields per image 100
● Number of password fields 1 000
● Number of visible switches per project 1 000
— visible switches per image 100
— hidden switches per image 100
● Number of status switches per project 1 000
— Number of status switches per image 100
● Number of selector switches per project 1 000
— Selector switches per image 100
● Number of decade switches per project 0
— Decade switches per image 0
● Number of signal lamps per project 1 000
— Signal lamps per image 100
Attributes for dynamic objects
● Color change Yes
● X/Y movement Yes
● Hide Yes
● Angle of rotation No
Lists
● Number of text lists per project 300
● Number of text lists per image 10
● Number of entries per text list 256
● Number of graphics lists per project 100
● Number of graphic lists per image 10
● Number of entries per graphics list 255
Security
● Number of user groups 10
● Password export/import Yes
Data carrier support
● PC card No
● CF card Yes
● Diskette drive No
● Hard disk No
● CD-ROM No
Logging through printer
● Recording/Printing Alarms, report (shift report)
Transfer (upload/download)
● Transfer of configuration MPI/PROFIBUS DP, serial, automatic transfer recognition
Process coupling
● Connection to controller S5, S7-200, S7- 300/400, TI 505, Win AC, SINUMERIK, SIMOTION, Allen Bradley (DF1), Mitsubishi (FX), Telemecanique (ADJUST), Modicon (Modbus), for further non-Siemens drivers, see section on "System interfaces"
● S7-200 Yes
— PPI (point-to-point) Yes
— PPI network No
— MPI Yes
— PROFIBUS DP Yes
● S7-300/400 Yes
— MPI Yes
— PROFIBUS DP Yes
— PROFINET No
● S5 Yes
— serial Yes
— PROFIBUS DP Yes
● TI 505 Yes
● Allen Bradley (DF1) Yes
● Allen Bradley (DF485) No
● Mitsubishi (FX) Yes
● Mitsubishi (MP4) Yes
● Telemecanique (ADJUST) Yes
● Telemecanique (Uni-Telway) Yes
● OMRON (LINK/Multilink) No
● Modicon (Modbus) Yes
● GE-Fanuc (SNP) Yes
Functions
● Key repeat No
● TAB sequence Yes
● Calculating functions Yes
● Animate Yes
● Menu tree editor No
● Unit switchover No
Service tools/configuration aids
● Clean screen Yes
● Touch calibration Yes
● Backup/Restore manually Yes
● Simulation Yes
● Device switchover Yes
● Delta transfer Yes
● Monitoring function for battery and memory Yes
● Trace (operation archive) No
Expandability/openness
● Open Platform Program Yes
Peripherals/Options
Peripherals Printer
SIMATIC HMI MM memory card: Multi Media Card No
SIMATIC HMI SD memory card: Secure Digital memory card No
USB memory No
Dimensions
Width of the housing front 212 mm
Height of housing front 156 mm
Overall depth 45 mm
Weights
Weight (without packaging) 0.7 kg

Fault description Possible solution
Why does the touch function of my TP170B no longer respond at the correct position? Siemens states that recalibration may become necessary if operator objects no longer respond correctly or if ageing and environmental influences have altered the touch position. On the TP170B, recalibration is performed via the Loader, then Control Panel, OP Properties, the Touch tab and Recalibrate. The calibration crosses must then be confirmed completely one after another, and the new values must be saved.
Why does WinCC flexible report during transfer that the project version and the operating system of the operator panel are not compatible? In this case, the device version selected in the project does not match the image or operating system version installed on the panel. Siemens describes updating the operating system via WinCC flexible or ProSave using the OS Update function together with the image file assigned to the TP170B. A backup should be created beforehand, as data stored on the operator panel may be deleted during the OS update.
Why can I not establish a connection to the TP170B via MPI or a serial interface? First check whether the required transfer channel is enabled on the panel. Siemens specifies enabling Serial Transfer or MPI/DP Transfer in the transfer settings. In addition, discussions in the SPS forum indicate that IF2 requires a serial cable rather than a null-modem cable, while IF1B/RS485 requires a PCMCIA CP with the appropriate MPI cable. Afterwards, compare the communication type, address and communication parameters on both the panel and the PG/PC.
Why does the message “The configured local node address is already assigned” appear? This message indicates that the same MPI address has been assigned twice. The SPS forum recommends checking the addresses of the PG, panel and CPU. It is also described that, after a runtime test, the PG may have been assigned the panel’s address. In this case, the PG address should be reset to its standard value and the connection should then be re-established.
Why does the TP170B display only a white or blank screen after start-up or after a transfer? Practical sources report this behaviour both after boot-up and after an apparently successful transfer. Siemens explains in the manual that if a restore process is interrupted or if compatibility conflicts exist, the operating system must be transferred again. Therefore, it is advisable first to check the panel’s image version and then reload the correct OS/image using ProSave before transferring the project again.

Which software can be used to engineer 6AV6545-0BB15-2AX0?

The panel is designed for ProTool/Lite from Version 5.2 SP1 and WinCC flexible Compact from Version 2004. For existing installations, this point is particularly important because an existing project can only be reused or migrated properly if the engineering version, image version and operator panel version are compatible. For retrofit or spare-parts projects, not only the panel itself but also the engineering environment should always be taken into consideration.

What power supply and protection rating does the TP170B require?

The device operates on 24 V DC and is rated IP65 at the front and IP20 at the rear. In practice, this means that the front is suitable for installation in machine fronts or control cabinets with appropriate sealing, while the rear requires a protected installation environment. Especially when sourcing a replacement, not only the part number but also the installation situation, front sealing and the existing 24 V supply should be checked.

Which interfaces should I check before ordering or replacing the device?

Before placing an order, at least the MPI/PROFIBUS-DP connection, the serial interfaces and the required transfer path should be verified. For the TP170B, optional TTY, 2 × RS232, 1 × RS422 and 1 × RS485 are specified. In practice, these interface configurations determine whether an existing project can continue to operate without modification or whether cables, adapters, addressing and transfer parameters must be adjusted. For purchasing and engineering departments, this is often the most important factor in avoiding incorrect orders and unnecessary downtime.

What can I use the CF card slot on the TP170B for?

The CF card slot is not only used as storage media but also for backup and restore operations. Siemens describes that data can be transferred between the memory card and the operator panel using the BACKUP and RESTORE functions. For operators of older systems, this is particularly valuable because it allows project versions to be secured, recovery procedures to be prepared and installed equipment to be protected more effectively. It is important not to remove the memory card while data is being accessed, as this may result in data loss.

Is 6AV6545-0BB15-2AX0 still a current product?

No. The available sources clearly indicate that this is a discontinued and obsolete product. The EICHLER product page lists EOP: 2008-04-01, and Siemens references the device as a spare part within the product lifecycle context. For users, this means that the panel should primarily be considered from the perspective of installed-base support, repairability, replacement options and supply security rather than as a current product generation.

When is repair more suitable than replacement or purchasing another unit?

Repair is particularly worthwhile when the existing panel fits the machine mechanically and functionally, the project is to be retained and the system must be returned to service quickly. For this device, EICHLER specifies a repair turnaround time of 1–3 days and includes technical cleaning, preventive maintenance, comprehensive functional testing and a minimum 24-month warranty. If, on the other hand, several devices are already failing, no project source is available or a complete spare-parts pool is being established, replacement or a tested spare unit may be the more economical option.

Is a newer panel automatically a direct 1:1 replacement?

This should not be assumed. Siemens identifies the TP170 series as discontinued and refers to later successor generations. At the same time, manuals and practical experience show that the image version, operating system, communication path and project version must all match correctly. Therefore, any replacement strategy should include verification of whether a functionally identical replacement is actually possible or whether project migration will be required.

Important documents

Repair accompanying note

Download the repair accompanying note as a PDF, or use the digital repair registration and send your defective modules to the EICHLER Service Centre for repair.

Laughing Eichler technician points to green PDF with special sale of automation technology

Quality & warranty

Outstanding service quality with every handle

Two Eichler technicians high-five each other after a successful repair

Your shopping basket

Loading shopping basket