SIEMENS 6AV6545-0BB15-2AX0
-
SIEMENS | HMI | Touch Panels
- EICHLER-art.no.: K0116923
- EAN: 4025515066125
Product description
SIMATIC Touch Panel TP 170B mono blue mode STN display MPI/PROFIBUS DP interface Printer/RS232 interface Slot for CF card configurable with ProTool/Lite as of Version V5.2+SP2
Services for SIEMENS 6AV6545-0BB15-2AX0
Repair
from 1.225,88 €
to 2.206,58 €
Replacement
1.514,70 €
Used
1.683,00 €
New
2.714,00 €
SIEMENS |
6AV6545-0BB15-2AX0 –
additional product information
| Delivery information | |||
|---|---|---|---|
| Export identifier | AL: ECCN: | ||
| Net weight | 0.7 | ||
| Quantity | 1 Stück | ||
| Packaging quantity | 1 | ||
| Additional product information | |||
|---|---|---|---|
| Product status | EOP: 2008-04-01 | ||
| EAN | 4025515066125 | ||
| UPC | / | ||
| Static lot number | 85371095 | ||
| List indicator | / | ||
| Product group | / | ||
| Country of origin | / | ||
| Compliance with the substance restrictions according to RoHS directive | Since: / | ||
| Product classifications | Version | Classification | |
|---|---|---|---|
| eClass | 4 | / | |
| eClass | 5.1 | / | |
| eClass | 6.0 | / | |
| ETIM | 3 | / | |
| ETIM | 4 | / | |
| ETIM | 5 | / | |
What is 6AV6545-0BB15-2AX0 and where is it used?
6AV6545-0BB15-2AX0 is a SIEMENS SIMATIC HMI TP 170B Mono touch panel designed for operating and monitoring machines and systems. The device features a 5.7-inch STN display with 4 blue-grey shades and is intended for classic HMI tasks such as entering setpoints, displaying alarms, visualising operating states and providing simple operator screens during production. Thanks to MPI/PROFIBUS-DP and additional serial interfaces, the panel is particularly suitable for existing installations where older SIMATIC architectures remain in operation. Typical applications include retrofit projects, spare-parts scenarios in maintenance environments and safeguarding production lines where the existing operating concept should be retained with minimal modification.
Overview of the key technical data and what they mean
The TP170B Mono features a resolution of 320 × 240 pixels, an analogue resistive touchscreen, a rated current consumption of 0.25 A and a typical power consumption of 6 W. For users, this means reliable operation for traditional machine screens, although it is not designed as a modern high-end graphics panel. Particularly important for replacement purposes are the available interfaces and bus systems: optional TTY, 2 × RS232, 1 × RS422, 1 × RS485 up to 12 Mbit/s, as well as a CF card slot. The front panel is rated IP65, while the rear is rated IP20. The device uses Windows CE as its pre-installed operating system and, according to the product data, can be engineered with ProTool/Lite from Version 5.2 SP1 or WinCC flexible Compact from Version 2004. Siemens documentation also specifies a 24 V DC power supply. For purchasing and technical departments, these factors are critical because they determine electrical compatibility, project retention and installation suitability.
Product status, life-cycle status and obsolescence
For 6AV6545-0BB15-2AX0, the EICHLER product page lists a product status of EOP: 2008-04-01. Siemens also identifies the device as a spare part in search results and indicates in product status notifications that the TP170 series has been discontinued. For operators, this means that the panel clearly falls into the category of obsolescence management and installed-base support. Anyone intending to continue operating a system with this operator panel should secure not only the part number but also the project status, interface configuration, image version and spare-parts strategy. Siemens references successor generations within later panel families for the discontinued TP170 range; however, a direct 1:1 drop-in replacement should not be assumed for this specific order number. Before replacement, project migration requirements, communication paths and software versions should always be verified.
Available EICHLER services and when they are relevant
For this panel, EICHLER offers repair, exchange, used equipment and new equipment as service options. The repair service is listed with a turnaround time of 1–3 days and includes technical cleaning, preventive maintenance, comprehensive functional testing and a minimum 24-month warranty. In addition, the shop information highlights up to 36 months warranty and guarantee, fully tested assemblies and 24/7 service. This is particularly relevant when production downtime is costly, migration is currently not feasible, or an original device is required at short notice. From a maintenance and purchasing perspective, these services provide a practical bridge between obsolescence and continued system availability: instead of relying on uncertain remaining stock, operational reliability can be maintained through repair, exchange or tested replacement units.
| Attribute | Value |
|---|---|
| Display | |
| Design of display | STN, 4 blue levels |
| Screen diagonal | 5.7 in |
| Resolution (pixels) | |
| ● Horizontal image resolution | 320 Pixel |
| ● Vertical image resolution | 240 Pixel |
| Backlighting | |
| ● MTBF backlighting (at 25 °C) | 50 000 h |
| Control elements | |
| Control elements | Touch screen |
| Keyboard fonts | |
| ● Numeric keyboard | Yes |
| ● alphanumeric keyboard | Yes |
| ● hexadecimal keyboard | Yes |
| ● Multi-key operation | No |
| Touch operation | |
| ● Design as touch screen | Yes; analog, resistive |
| Connection type | |
| ● Type of connection for mouse/keyboard/barcode reader | - / - / - |
| Installation type/mounting | |
| Mounting position | vertical |
| maximum permissible angle of inclination without external ventilation | 35° |
| Input current | |
| Current consumption (rated value) | 0.25 A |
| Power | |
| Active power input, typ. | 6 W |
| Processor | |
| Processor type | RISC 32 bit, 66 MHz |
| Memory | |
| Type of memory | Flash / RAM |
| Memory available for user data | 768 kbyte |
| Time of day | |
| Clock | |
| ● Type | Software clock, synchronizable, no battery backup |
| ● retentive | No |
| ● synchronizable | Yes |
| Interfaces | |
| Interfaces/bus type | TTY optional, 2x RS 232, 1x RS 422, 1x RS 485 (max. 12 Mbit/s) |
| CF card slot | 1x CF card slot |
| Degree and class of protection | |
| IP (at the front) | IP65 |
| IP (rear) | IP20 |
| Standards, approvals, certificates | |
| Certificate of suitability | CE, FM Class I Div. 2, UL, CSA |
| Ambient conditions | |
| Ambient temperature during storage/transportation | |
| ● min. | -20 °C |
| ● max. | 60 °C |
| Relative humidity | |
| ● Operation, max. | 85 % |
| Operating systems | |
| pre-installed operating system | Windows CE |
| Configuration | |
| Configuration software | |
| ● Configuration tool | ProTool / Lite, Version 5.2 SP 1 or higher or WinCC flexible Compact Version 2004 or higher (to be ordered separately) |
| Languages | |
| Online languages | |
| ● Number of online/runtime languages | 5 |
| Project languages | |
| ● Languages per project | 32 |
| Functionality under WinCC (TIA Portal) | |
| Libraries | Yes |
| Task planner | Yes |
| Help system | Yes |
| ● Number of characters per info text | 70 |
| ● Number of tooltips | 0 |
| Message system | |
| ● Number of alarm classes | 32 |
| ● Number of messages | 2 000 |
| ● Bit messages | Yes |
| — Number of bit messages | 2 000 |
| ● Analog messages | Yes |
| — Number of analog messages | 2 000 |
| ● Telegram message procedure Alarm S | No |
| ● System messages HMI | Yes |
| ● System messages PLC | No |
| ● System messages, other (SIMATIC S7, Sinumerik, Simotion, etc.) | No |
| ● Lines | 1 |
| ● Number of characters per message | 80 |
| ● Number of process values per message | 8 |
| ● Acknowledgment groups | |
| — Number of acknowledgement groups | 99 |
| ● Message indicator | Yes |
| ● acoustic feedback | No |
| ● First/last value | Yes |
| Recipe management | |
| ● Number of recipes | 100 |
| ● Data records per recipe | 200 |
| ● Entries per data record | 200 |
| ● Recipe memory | 32 KB integrated Flash, expandable |
| Variables | |
| ● Number of variables per device | 1 000 |
| ● Number of variables per screen | 50 |
| ● Number of variables | 1 000 |
| ● Initial values | 1 000 |
| ● Type Date & Time | 1 000 |
| ● Limit values | Yes |
| ● Multiplexing | Yes |
| ● Structures | No |
| Images | |
| ● Number of configurable images | 100 |
| ● Permanent window/default | Yes |
| ● Start screen configurable | Yes |
| ● Image selection by PLC | Yes |
| ● Image number in the PLC | Yes |
| Image objects | |
| ● Text objects | 2 000 text elements |
| ● Number of I/O fields per image | 0 |
| ● Number of date/time fields | 30 |
| ● Index of screen context | No |
| ● Return | Yes |
| ● Graphics object | Bit maps, icons, icon (full-screen) |
| — Icons | 500 |
| — Icon (full screen) | 50 |
| Complex image objects | |
| ● Status/control | Not possible |
| ● dynamic objects | Diagrams, bar graphs, invisible buttons |
| — Number of objects per project | 500 |
| — Number of curve diagrams per image | 5 |
| ● Methods | Trend |
| ● Bar graphs | |
| — Number of bars per chart | 5 |
| ● Sliders | |
| — Number of slides per image | 0 |
| ● Pointer instruments | |
| — Number of analog indicators per image | 0 |
| ● Limit value lines | Yes |
| ● Number of alphanumerical fields | 1 000 |
| — alphanumeric fields per image | 100 |
| ● Number of numerical fields | 1 000 |
| — numerical fields per image | 100 |
| ● Number of password fields | 1 000 |
| ● Number of visible switches per project | 1 000 |
| — visible switches per image | 100 |
| — hidden switches per image | 100 |
| ● Number of status switches per project | 1 000 |
| — Number of status switches per image | 100 |
| ● Number of selector switches per project | 1 000 |
| — Selector switches per image | 100 |
| ● Number of decade switches per project | 0 |
| — Decade switches per image | 0 |
| ● Number of signal lamps per project | 1 000 |
| — Signal lamps per image | 100 |
| Attributes for dynamic objects | |
| ● Color change | Yes |
| ● X/Y movement | Yes |
| ● Hide | Yes |
| ● Angle of rotation | No |
| Lists | |
| ● Number of text lists per project | 300 |
| ● Number of text lists per image | 10 |
| ● Number of entries per text list | 256 |
| ● Number of graphics lists per project | 100 |
| ● Number of graphic lists per image | 10 |
| ● Number of entries per graphics list | 255 |
| Security | |
| ● Number of user groups | 10 |
| ● Password export/import | Yes |
| Data carrier support | |
| ● PC card | No |
| ● CF card | Yes |
| ● Diskette drive | No |
| ● Hard disk | No |
| ● CD-ROM | No |
| Logging through printer | |
| ● Recording/Printing | Alarms, report (shift report) |
| Transfer (upload/download) | |
| ● Transfer of configuration | MPI/PROFIBUS DP, serial, automatic transfer recognition |
| Process coupling | |
| ● Connection to controller | S5, S7-200, S7- 300/400, TI 505, Win AC, SINUMERIK, SIMOTION, Allen Bradley (DF1), Mitsubishi (FX), Telemecanique (ADJUST), Modicon (Modbus), for further non-Siemens drivers, see section on "System interfaces" |
| ● S7-200 | Yes |
| — PPI (point-to-point) | Yes |
| — PPI network | No |
| — MPI | Yes |
| — PROFIBUS DP | Yes |
| ● S7-300/400 | Yes |
| — MPI | Yes |
| — PROFIBUS DP | Yes |
| — PROFINET | No |
| ● S5 | Yes |
| — serial | Yes |
| — PROFIBUS DP | Yes |
| ● TI 505 | Yes |
| ● Allen Bradley (DF1) | Yes |
| ● Allen Bradley (DF485) | No |
| ● Mitsubishi (FX) | Yes |
| ● Mitsubishi (MP4) | Yes |
| ● Telemecanique (ADJUST) | Yes |
| ● Telemecanique (Uni-Telway) | Yes |
| ● OMRON (LINK/Multilink) | No |
| ● Modicon (Modbus) | Yes |
| ● GE-Fanuc (SNP) | Yes |
| Functions | |
| ● Key repeat | No |
| ● TAB sequence | Yes |
| ● Calculating functions | Yes |
| ● Animate | Yes |
| ● Menu tree editor | No |
| ● Unit switchover | No |
| Service tools/configuration aids | |
| ● Clean screen | Yes |
| ● Touch calibration | Yes |
| ● Backup/Restore manually | Yes |
| ● Simulation | Yes |
| ● Device switchover | Yes |
| ● Delta transfer | Yes |
| ● Monitoring function for battery and memory | Yes |
| ● Trace (operation archive) | No |
| Expandability/openness | |
| ● Open Platform Program | Yes |
| Peripherals/Options | |
| Peripherals | Printer |
| SIMATIC HMI MM memory card: Multi Media Card | No |
| SIMATIC HMI SD memory card: Secure Digital memory card | No |
| USB memory | No |
| Dimensions | |
| Width of the housing front | 212 mm |
| Height of housing front | 156 mm |
| Overall depth | 45 mm |
| Weights | |
| Weight (without packaging) | 0.7 kg |
| Fault description | Possible solution |
|---|---|
| Why does the touch function of my TP170B no longer respond at the correct position? | Siemens states that recalibration may become necessary if operator objects no longer respond correctly or if ageing and environmental influences have altered the touch position. On the TP170B, recalibration is performed via the Loader, then Control Panel, OP Properties, the Touch tab and Recalibrate. The calibration crosses must then be confirmed completely one after another, and the new values must be saved. |
| Why does WinCC flexible report during transfer that the project version and the operating system of the operator panel are not compatible? | In this case, the device version selected in the project does not match the image or operating system version installed on the panel. Siemens describes updating the operating system via WinCC flexible or ProSave using the OS Update function together with the image file assigned to the TP170B. A backup should be created beforehand, as data stored on the operator panel may be deleted during the OS update. |
| Why can I not establish a connection to the TP170B via MPI or a serial interface? | First check whether the required transfer channel is enabled on the panel. Siemens specifies enabling Serial Transfer or MPI/DP Transfer in the transfer settings. In addition, discussions in the SPS forum indicate that IF2 requires a serial cable rather than a null-modem cable, while IF1B/RS485 requires a PCMCIA CP with the appropriate MPI cable. Afterwards, compare the communication type, address and communication parameters on both the panel and the PG/PC. |
| Why does the message “The configured local node address is already assigned” appear? | This message indicates that the same MPI address has been assigned twice. The SPS forum recommends checking the addresses of the PG, panel and CPU. It is also described that, after a runtime test, the PG may have been assigned the panel’s address. In this case, the PG address should be reset to its standard value and the connection should then be re-established. |
| Why does the TP170B display only a white or blank screen after start-up or after a transfer? | Practical sources report this behaviour both after boot-up and after an apparently successful transfer. Siemens explains in the manual that if a restore process is interrupted or if compatibility conflicts exist, the operating system must be transferred again. Therefore, it is advisable first to check the panel’s image version and then reload the correct OS/image using ProSave before transferring the project again. |
Which software can be used to engineer 6AV6545-0BB15-2AX0?
The panel is designed for ProTool/Lite from Version 5.2 SP1 and WinCC flexible Compact from Version 2004. For existing installations, this point is particularly important because an existing project can only be reused or migrated properly if the engineering version, image version and operator panel version are compatible. For retrofit or spare-parts projects, not only the panel itself but also the engineering environment should always be taken into consideration.
What power supply and protection rating does the TP170B require?
The device operates on 24 V DC and is rated IP65 at the front and IP20 at the rear. In practice, this means that the front is suitable for installation in machine fronts or control cabinets with appropriate sealing, while the rear requires a protected installation environment. Especially when sourcing a replacement, not only the part number but also the installation situation, front sealing and the existing 24 V supply should be checked.
Which interfaces should I check before ordering or replacing the device?
Before placing an order, at least the MPI/PROFIBUS-DP connection, the serial interfaces and the required transfer path should be verified. For the TP170B, optional TTY, 2 × RS232, 1 × RS422 and 1 × RS485 are specified. In practice, these interface configurations determine whether an existing project can continue to operate without modification or whether cables, adapters, addressing and transfer parameters must be adjusted. For purchasing and engineering departments, this is often the most important factor in avoiding incorrect orders and unnecessary downtime.
What can I use the CF card slot on the TP170B for?
The CF card slot is not only used as storage media but also for backup and restore operations. Siemens describes that data can be transferred between the memory card and the operator panel using the BACKUP and RESTORE functions. For operators of older systems, this is particularly valuable because it allows project versions to be secured, recovery procedures to be prepared and installed equipment to be protected more effectively. It is important not to remove the memory card while data is being accessed, as this may result in data loss.
Is 6AV6545-0BB15-2AX0 still a current product?
No. The available sources clearly indicate that this is a discontinued and obsolete product. The EICHLER product page lists EOP: 2008-04-01, and Siemens references the device as a spare part within the product lifecycle context. For users, this means that the panel should primarily be considered from the perspective of installed-base support, repairability, replacement options and supply security rather than as a current product generation.
When is repair more suitable than replacement or purchasing another unit?
Repair is particularly worthwhile when the existing panel fits the machine mechanically and functionally, the project is to be retained and the system must be returned to service quickly. For this device, EICHLER specifies a repair turnaround time of 1–3 days and includes technical cleaning, preventive maintenance, comprehensive functional testing and a minimum 24-month warranty. If, on the other hand, several devices are already failing, no project source is available or a complete spare-parts pool is being established, replacement or a tested spare unit may be the more economical option.
Is a newer panel automatically a direct 1:1 replacement?
This should not be assumed. Siemens identifies the TP170 series as discontinued and refers to later successor generations. At the same time, manuals and practical experience show that the image version, operating system, communication path and project version must all match correctly. Therefore, any replacement strategy should include verification of whether a functionally identical replacement is actually possible or whether project migration will be required.