SIEMENS 6AV2124-0JC01-0AX0

  • EICHLER-art.no.: K0251525
  • EAN: 4025515079019
  • UPC: 040892686043

Product description

SIMATIC HMI TP900 COMFORT, COMFORT PANEL, TOUCH OPERATION, 9 WIDESCREEN-TFT-DISPLAY, 16 MIL. COLORS, PROFINET INTERFACE, MPI/PROFIBUS DP INTERFACE, 12 MB USER MEMORY, WINDOWS CE 6.0, CONFIGURABLE FROM WINCC COMFORT V11

Services for SIEMENS 6AV2124-0JC01-0AX0

Repair

1-3 days

from 1.086,87 €

to 1.956,37 €

per pc. 159,00 €

Replacement

1-3 days

10+ Pcs.

2.113,20 €

per pc. 159,00 €

2.113,20 € *

Please enter an offer recipient here.


Used

1-3 days

10+ Pcs.

2.348,00 €

per pc. 159,00 €

2.348,00 € *

Please enter an offer recipient here.


New

1-3 days

10+ Pcs.

2.582,80 €

2.582,80 € *

Please enter an offer recipient here.


Delivery information
Export identifier AL: N ECCN: 5A992
Net weight 2.482
Quantity 1 Stück
Packaging quantity 1
Additional product information
Product status
EAN 4025515079019
UPC 040892686043
Static lot number 85371091
List indicator ST80.1N
Product group 3404
Country of origin DE
Compliance with the substance restrictions according to RoHS directive Since: 20110131
Product classifications Version Classification
eClass 4 27-36-01-02
eClass 5.1 27-24-23-02
eClass 6.0 27-24-23-02
ETIM 3 /
ETIM 4 EC001412
ETIM 5 EC001412

What is the 6AV2124-0JC01-0AX0 and where is it used

The 6AV2124-0JC01-0AX0 is the SIMATIC HMI TP900 Comfort from Siemens, a 9-inch Comfort Panel for machine-level visualisation and operation in industrial systems. The device is designed for more demanding HMI applications where operators need to view process values, acknowledge alarms, modify parameters or use recipes. This panel is particularly relevant in existing installations because it combines PROFINET and MPI/PROFIBUS-DP, making it suitable for both modern and legacy Siemens environments. The device can be configured from WinCC Comfort V11 onwards, which is a key factor for retrofit projects, spare parts procurement and replacement planning. For maintenance personnel and purchasing departments, the exact article number is important because it uniquely defines the display size, communication interfaces and installation dimensions.

Overview of the most important technical data and what they mean

The TP900 Comfort features a 9-inch TFT widescreen display with 800 × 480 pixels and 16.7 million colours. For control cabinet applications, this provides clear visualisation of typical machine and process screens. The analogue resistive touch interface is designed for conventional industrial applications. Electrically, the panel requires 24 V DC with a permissible range of 19.2 to 28.8 V; typical power consumption is 18 W. Communication interfaces include Industrial Ethernet with integrated 2-port switch, RS422/RS485 for MPI/PROFIBUS-DP, 2 × USB 2.0 and 2 SD card slots. Additional specifications include IP65 protection at the front, IP20 at the rear, an installation depth of 62.7 mm and a panel cut-out of 251 × 166 mm. These characteristics are particularly important for replacement projects, wiring requirements and mechanical compatibility.

Product status, life-cycle status and obsolescence

For the 6AV2124-0JC01-0AX0, Siemens currently lists the product status PM400: Product phase-out announcement, with an effective date of 31 January 2026. For operators, this means that the panel is still clearly identifiable and widely available through service and spare-parts channels, but from a life-cycle perspective it is already moving towards obsolescence management. Siemens also identifies 6AV2128-3KB06-0AX1 as a successor reference. In Siemens documentation, this device is positioned as the MTP1000 Unified Comfort within modernisation concepts for the TP900 Comfort. For purchasers and decision-makers, this is important because successor selection involves not only availability but also project migration, communication interfaces and the overall modernisation effort.

Available EICHLER services and when they are relevant

For the 6AV2124-0JC01-0AX0, EICHLER offers repair, replacement, used equipment and new equipment. In active production environments, this is particularly important because a 1:1 replacement or a professionally executed repair often restores availability more quickly than a complete modernisation project. The repair service includes technical cleaning, preventive maintenance, comprehensive functional testing and a minimum 24-month warranty; an optional test report is also available. This is especially relevant for maintenance teams when the existing panel cut-out, project status and communication setup are to remain unchanged. For purchasing departments and production managers, the combination of repair and replacement options helps reduce the risk of extended downtime, particularly when a product has already entered its phase-out stage. These services are intended for business customers.

Attribute Value
Product type designation TP900 Comfort
Display
Design of display TFT
Screen diagonal 9 in
Display width 195 mm
Display height 117 mm
Number of colors 16 777 216
Resolution (pixels)
● Horizontal image resolution 800 pixel
● Vertical image resolution 480 pixel
Backlighting
● MTBF backlighting (at 25 °C) 80 000 h
● Backlight dimmable Yes; 0-100 %
Control elements
Keyboard fonts
● Function keys
— Number of function keys 0
— Number of function keys with LEDs 0
● Keys with LED No
● System keys No
● Numeric keyboard Yes; Onscreen keyboard
● alphanumeric keyboard Yes; Onscreen keyboard
Touch operation
● Design as touch screen Yes; Analog-resistive
Expansions for operator control of the process
● DP direct LEDs (LEDs as S7 output I/O)
— F1...Fx 0
● Direct keys (keys as S7 input I/O)
— F1...Fx 0
● Direct keys (touch buttons as S7 input I/O) 40
Installation type/mounting
Mounting position vertical
Wall mounting/direct mounting No
Mounting in portrait format possible Yes
Mounting in landscape format possible Yes
maximum permissible angle of inclination without external ventilation 35°
Supply voltage
Type of supply voltage DC
Rated value (DC) 24 V
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V
Input current
Current consumption (rated value) 0.75 A
Starting current inrush I²t 0.5 A²·s
Power
Active power input, typ. 18 W
Processor
Processor type X86
Memory
Flash Yes
RAM Yes
Memory available for user data 12 Mbyte
Type of output
Info LED No
Power LED No
Error LED No
Acoustics
● Buzzer No
● Speaker Yes
Time of day
Clock
● Hardware clock (real-time) Yes
● Software clock Yes
● retentive Yes; Back-up duration typically 6 weeks
● synchronizable Yes
Interfaces
Number of industrial Ethernet interfaces 1; 2 ports (switch)
Number of RS 485 interfaces 1; RS 422 / 485 combined
Number of RS 422 interfaces 0; together with RS 485
Number of RS 232 interfaces 0
Number of USB interfaces 2; USB 2.0
● USB Mini B 1; 5-pole
Number of 20 mA interfaces (TTY) 0
Number of parallel interfaces 0
Number of other interfaces 0
Number of SD card slots 2
With software interfaces No
Industrial Ethernet
● Industrial Ethernet status LED 2
● Number of ports of the integrated switch 2
Protocols
PROFINET Yes
Supports protocol for PROFINET IO Yes
IRT Yes; As of WinCC V12
PROFIBUS Yes
EtherNet/IP Yes
MPI Yes
Protocols (Ethernet)
● TCP/IP Yes
● DHCP Yes
● SNMP Yes
● DCP Yes
● LLDP Yes
WEB characteristics
● HTTP Yes
● HTTPS Yes
● HTML Yes
● XML Yes
● CSS Yes
● Active X Yes
● JavaScript Yes
● Java VM No
Redundancy mode
Media redundancy
— MRP Yes; As of WinCC V12
Further protocols
● CAN No
● MODBUS Yes
Interrupts/diagnostics/status information
Diagnoses
● Diagnostic information readable Yes; S7 controller
EMC
Emission of radio interference acc. to EN 55 011
● Limit class A, for use in industrial areas Yes
● Limit class B, for use in residential areas No
Degree and class of protection
IP (at the front) IP65
IP (rear) IP20
NEMA (front)
● Enclosure Type 4 at the front Yes
● Enclosure Type 4x at the front Yes
Standards, approvals, certificates
CE mark Yes
cULus Yes
RCM (formerly C-TICK) Yes
KC approval Yes
Ecological footprint
● environmental product declaration Yes
Global warming potential
— global warming potential, (total) [CO2 eq] 254 kg
— global warming potential, (during production) [CO2 eq] 61.5 kg
— global warming potential, (during operation) [CO2 eq] 194 kg
— global warming potential, (after end of life cycle) [CO2 eq] -1.87 kg
Use in hazardous areas
● ATEX Zone 2 Yes
● ATEX Zone 22 Yes
● IECEx Zone 2 Yes
● IECEx Zone 22 Yes
● cULus Class I Zone 1 No
● cULus Class I Zone 2, Division 2 Yes
● FM Class I Division 2 Yes
Marine approval
● Germanischer Lloyd (GL) Yes
● American Bureau of Shipping (ABS) Yes
● Bureau Veritas (BV) Yes
● Det Norske Veritas (DNV) Yes
● Lloyds Register of Shipping (LRS) Yes
● Nippon Kaiji Kyokai (Class NK) Yes
● Polski Rejestr Statkow (PRS) No
Ambient conditions
Suited for indoor use Yes
Suited for outdoor use No
Ambient temperature during operation
Operation (vertical installation)
— For vertical installation, min. 0 °C
— For vertical installation, max. 50 °C; (55 °C, see entry ID: 64847814)
Operation (max. tilt angle)
— At maximum tilt angle, min. 0 °C
— At maximum tilt angle, max. 40 °C
Operation (vertical installation, portrait format)
— For vertical installation, min. 0 °C
— For vertical installation, max. 40 °C
Operation (max. tilt angle, portrait format)
— At maximum tilt angle, min. 0 °C
— At maximum tilt angle, max. 35 °C
Ambient temperature during storage/transportation
● min. -20 °C
● max. 60 °C
Relative humidity
● Operation, max. 90 %; no condensation
Operating systems
proprietary No
pre-installed operating system
● Windows CE Yes
Configuration
Message indicator Yes
Alarm system (incl. buffer and acknowledgment) Yes
Process value display (output) Yes
Process value default (input) possible Yes
Recipe management Yes
Configuration software
● STEP 7 Basic (TIA Portal) No
● STEP 7 Professional (TIA Portal) No
● WinCC flexible Compact No
● WinCC flexible Standard No
● WinCC flexible Advanced No
● WinCC Basic (TIA Portal) No
● WinCC Comfort (TIA Portal) Yes; from V11
● WinCC Advanced (TIA Portal) Yes; from V11
● WinCC Professional (TIA Portal) Yes; from V11
Languages
Online languages
● Number of online/runtime languages 32
Project languages
● Languages per project 32
Functionality under WinCC (TIA Portal)
Libraries Yes
Applications/options
● Web browser Yes
● Pocket Word Yes
● Pocket Excel Yes
● PDF Viewer Yes
● Media Player Yes
● SIMATIC WinCC Sm@rtServer Yes
● SIMATIC WinCC Audit Yes
Number of Visual Basic Scripts Yes
Task planner
● time-controlled Yes
● task-controlled Yes
Help system
● Number of characters per info text 70
Message system
● Number of alarm classes 32
● Bit messages Yes
— Number of bit messages 4 000
● Analog messages Yes
— Number of analog messages 200
● S7 alarm number procedure Yes
● System messages HMI Yes
● System event, more (SIMATIC S7, SINUMERIK, SIMOTION, ... ) Yes
● Number of characters per message 80
● Number of process values per message 8
● Acknowledgment groups Yes
● Message indicator Yes
● Message buffer
— Number of entries 1 024
— Circulating buffer Yes
— retentive Yes
— maintenance-free Yes
Recipe management
● Number of recipes 300
● Data records per recipe 500
● Entries per data record 1 000
● Size of internal recipe memory 2 Mbyte
● Recipe memory expandable Yes
Variables
● Number of variables per device 2 048
● Number of variables per screen 400
● Limit values Yes
● Multiplexing Yes
● Structures Yes
● Arrays Yes
Images
● Number of configurable images 500
● Permanent window/default Yes
● Global image Yes
● Pop-up images Yes
● Slide-in images Yes
● Image selection by PLC Yes
● Image number in the PLC Yes
Image objects
● Number of objects per image 400
● Text fields Yes
● I/O fields Yes
● Graphic I/O fields (graphics list) Yes
● Symbolic I/O fields (text list) Yes
● Date/time fields Yes
● Switches Yes
● Buttons Yes
● Graphic display Yes
● Icons Yes
● Geometric objects Yes
Complex image objects
● Number of complex objects per screen 20
● Alarm view Yes
● Trend view Yes
● User view Yes
● Status/control Yes
● Sm@rtClient view Yes
● Recipe view Yes
● f(x) trend view Yes
● System diagnostics view Yes
● Media Player Yes
● HTML browser Yes
● PDF display Yes
● IP camera display Yes
● Bar graphs Yes
● Sliders Yes
● Pointer instruments Yes
● Analog/digital clock Yes
Lists
● Number of text lists per project 500
● Number of entries per text list 500
● Number of graphics lists per project 500
● Number of entries per graphics list 500
Archiving
● Number of archives per device 50
● Number of entries per archive 20 000
● Message archive Yes
● Process value archive Yes
● Archiving methods
— Sequential archive Yes
— Short-term archive Yes
● Memory location
— Memory card Yes
— USB memory Yes
— Ethernet Yes
● Data storage format
— CSV Yes
— TXT Yes
— RDB Yes
Security
● Number of user groups 50
● Number of user rights 32
● Number of users 50
● Password export/import Yes
● SIMATIC Logon Yes
Logging through printer
● Alarms Yes
● Report (shift log) Yes
● Hardcopy Yes
● Electronic print to file Yes; PDF, HTML
Character sets
● Keyboard fonts
— US English Yes
Transfer (upload/download)
● MPI/PROFIBUS DP Yes
● USB Yes
● Ethernet Yes
● using external storage medium Yes
Process coupling
● S7-1200 Yes
● S7-1500 Yes
● S7-200 Yes
● S7-300/400 Yes
● LOGO! Yes
● WinAC Yes
● SINUMERIK Yes; with SINUMERIK option package
● SIMOTION Yes
● Allen Bradley (EtherNet/IP) Yes
● Allen Bradley (DF1) Yes
● Mitsubishi (MC TCP/IP) Yes
● Mitsubishi (FX) Yes
● OMRON (FINS TCP) No
● OMRON (LINK/Multilink) Yes
● Modicon (Modbus TCP/IP) Yes
● Modicon (Modbus) Yes
● OPC UA Client Yes
● OPC UA Server Yes
Service tools/configuration aids
● Backup/Restore manually Yes
● Backup/Restore automatically Yes
● Simulation Yes
● Device switchover Yes
Peripherals/Options
Printer Yes
SIMATIC HMI MM memory card: Multi Media Card Yes; Up to 128 MB
SIMATIC HMI SD memory card: Secure Digital memory card Yes; Up to 2 GB
SIMATIC HMI CF memory card Compact Flash Card No
USB memory Yes
SIMATIC IPC USB Flashdrive (USB stick) Yes; Up to 16 GB
SIMATIC HMI USB stick Yes; Up to 8 GB
Network camera Yes
Mechanics/material
Enclosure material (front)
● Plastic No
● Aluminum Yes
● Stainless steel No
Dimensions
Width of the housing front 274 mm
Height of housing front 190 mm
Mounting cutout, width 251 mm
Mounting cutout, height 166 mm
mounting depth 62.7 mm
Weights
Weight (without packaging) 1.9 kg
Weight (with packaging) 2.6 kg

Fault description Possible solution
Why does ProSave or TIA not find my TP900 Comfort even though a ping works? First check the transfer settings in the panel and the transfer channel actually selected. In many cases, a different transfer path is configured in the operator panel than in the engineering software. Also place the panel explicitly into transfer mode, verify the IP address, subnet and duplicate IP addresses, and, if necessary, test Ethernet instead of PN/IE or vice versa.
Why is the download aborted due to a transfer error? Check whether the correct panel type is actually configured in the project and whether the HMI image file matching the TIA/WinCC version in use is available. If there is a version conflict between the project version and the panel image, the transfer will be aborted. In this case, first perform the appropriate OS/image update and then restart the project transfer.
Why does the touch screen respond inaccurately or stop responding correctly? On the TP900 Comfort, the touch screen can be recalibrated via Control Panel > OP > Touch. After OS-related work or if unusual operating behaviour occurs, the calibration should be checked. If operation remains inaccurate, inspect the front panel for mechanical damage, as Siemens points out that pointed or hard objects can damage the touch surface and may ultimately cause complete failure.
Why does restore not work on the replacement panel? Backup and restore functions on Comfort Panels are intended for the original device or a panel of the same type. Therefore, use an identical or equivalent panel model. Only devices of the same type reliably support restoring a backup; if the device type or hardware variant differs, the automatic restoration process will typically fail.
Why can I not access the Control Panel or reset the panel to factory settings? Check whether password protection or SecureMode is active. Siemens states that enabling password protection automatically activates SecureMode. In this case, local changes in the Control Panel are only possible with the correct password. If the password is unknown, a simple local reset is generally not possible and the documented service procedure must be followed.

Is the 6AV2124-0JC01-0AX0 already discontinued?

Siemens currently lists the device with the life-cycle status PM400: Product phase-out announcement. Siemens specifies 31 January 2026 as the effective date. For procurement, this does not automatically mean that no material is available anymore, but supply should be planned proactively. It is precisely during this phase that repairs, replacement units, used assemblies and clearly defined spare-part strategies become particularly important in order to avoid unplanned system downtime.

Which successor is specified for the 6AV2124-0JC01-0AX0?

Siemens identifies 6AV2128-3KB06-0AX1 as the successor reference for the TP900 Comfort. In Siemens modernisation documentation, this device is positioned as the MTP1000 Unified Comfort within the successor context of the TP900 Comfort. For migration projects, it is important not to focus solely on the article number, but also to evaluate project migration, the visualisation concept and the mechanical integration. A successor is therefore not automatically a completely seamless 1:1 replacement but rather part of a structured modernisation assessment.

Which software can be used to configure the TP900 Comfort?

The 6AV2124-0JC01-0AX0 can be configured from WinCC Comfort V11 onwards. This information is particularly relevant for maintenance and engineering teams when an existing project needs to be reloaded, extended or checked for compatibility. It should also be noted that the panel is based on Windows CE 6.0. For operators of older machinery, this combination is typical, but it also indicates that existing installations should be carefully assessed when modifications or cybersecurity considerations are involved.

Which interfaces are particularly important when replacing the panel?

For replacement projects in existing installations, the communication and power-supply specifications are especially important. The panel provides PROFINET via Industrial Ethernet with an integrated 2-port switch, MPI/PROFIBUS-DP via the combined RS422/485 interface, as well as 2 × USB 2.0 and 2 SD card slots. The device operates on 24 V DC, with a permissible range of 19.2 to 28.8 V. This combination makes the panel particularly attractive in systems where legacy fieldbus structures and newer Ethernet-based communication coexist.

Can I restore a backup to another panel?

Yes, but only under specific conditions. Siemens describes the backup/restore and automatic service concept in such a way that restoration is intended for the original device or for an operator panel of the same type. For operators, this is a critical point: a backup is extremely valuable, but it does not eliminate the need to verify exact hardware compatibility. Anyone aiming to minimise downtime should therefore plan for an identical replacement panel or an appropriate spare-part strategy.

Can I retrieve the original project from a running TP900 Comfort?

A backup secures the device data required for operation, but it is not the same as a fully editable engineering project. Siemens points out that HMI runtime data cannot simply be loaded back into a TIA Portal or WinCC project and then edited normally. For modifications, expansions or migrations, the original project remains essential. Nevertheless, backup/restore remains indispensable for ensuring a fast recovery in the event of a fault.

When is a repair more appropriate than a complete replacement?

Repair is particularly advantageous when the panel cut-out, wiring, existing WinCC project and machine approval should remain unchanged. For this panel, EICHLER offers repairs including technical cleaning, preventive maintenance, comprehensive functional testing and a minimum 24-month warranty. This is especially attractive for existing production systems because the current integration remains intact and recommissioning can often be organised more quickly than a complete modernisation project. In addition, replacement, used-equipment and new-equipment options are available.

Important documents

Repair accompanying note

Download the repair accompanying note as a PDF, or use the digital repair registration and send your defective modules to the EICHLER Service Centre for repair.

Laughing Eichler technician points to green PDF with special sale of automation technology

Your shopping basket

Loading shopping basket