SIEMENS 6AV2124-0JC01-0AX0
-
SIEMENS | HMI | Touch Panels
- EICHLER-art.no.: K0251525
- EAN: 4025515079019
- UPC: 040892686043
Product description
SIMATIC HMI TP900 COMFORT, COMFORT PANEL, TOUCH OPERATION, 9 WIDESCREEN-TFT-DISPLAY, 16 MIL. COLORS, PROFINET INTERFACE, MPI/PROFIBUS DP INTERFACE, 12 MB USER MEMORY, WINDOWS CE 6.0, CONFIGURABLE FROM WINCC COMFORT V11
Services for SIEMENS 6AV2124-0JC01-0AX0
Repair
from 1.090,38 €
to 1.962,68 €
Replacement
2.113,20 €
Used
2.348,00 €
New
2.582,80 €
SIEMENS |
6AV2124-0JC01-0AX0 –
additional product information
| Delivery information | |||
|---|---|---|---|
| Export identifier | AL: N ECCN: 5A992 | ||
| Net weight | 2.482 | ||
| Quantity | 1 Stück | ||
| Packaging quantity | 1 | ||
| Additional product information | |||
|---|---|---|---|
| Product status | |||
| EAN | 4025515079019 | ||
| UPC | 040892686043 | ||
| Static lot number | 85371091 | ||
| List indicator | ST80.1N | ||
| Product group | 3404 | ||
| Country of origin | DE | ||
| Compliance with the substance restrictions according to RoHS directive | Since: 20110131 | ||
| Product classifications | Version | Classification | |
|---|---|---|---|
| eClass | 4 | 27-36-01-02 | |
| eClass | 5.1 | 27-24-23-02 | |
| eClass | 6.0 | 27-24-23-02 | |
| ETIM | 3 | / | |
| ETIM | 4 | EC001412 | |
| ETIM | 5 | EC001412 | |
What is the 6AV2124-0JC01-0AX0 and where is it used
The 6AV2124-0JC01-0AX0 is the SIMATIC HMI TP900 Comfort from Siemens, a 9-inch Comfort Panel for machine-level visualisation and operation in industrial systems. The device is designed for more demanding HMI applications where operators need to view process values, acknowledge alarms, modify parameters or use recipes. This panel is particularly relevant in existing installations because it combines PROFINET and MPI/PROFIBUS-DP, making it suitable for both modern and legacy Siemens environments. The device can be configured from WinCC Comfort V11 onwards, which is a key factor for retrofit projects, spare parts procurement and replacement planning. For maintenance personnel and purchasing departments, the exact article number is important because it uniquely defines the display size, communication interfaces and installation dimensions.
Overview of the most important technical data and what they mean
The TP900 Comfort features a 9-inch TFT widescreen display with 800 × 480 pixels and 16.7 million colours. For control cabinet applications, this provides clear visualisation of typical machine and process screens. The analogue resistive touch interface is designed for conventional industrial applications. Electrically, the panel requires 24 V DC with a permissible range of 19.2 to 28.8 V; typical power consumption is 18 W. Communication interfaces include Industrial Ethernet with integrated 2-port switch, RS422/RS485 for MPI/PROFIBUS-DP, 2 × USB 2.0 and 2 SD card slots. Additional specifications include IP65 protection at the front, IP20 at the rear, an installation depth of 62.7 mm and a panel cut-out of 251 × 166 mm. These characteristics are particularly important for replacement projects, wiring requirements and mechanical compatibility.
Product status, life-cycle status and obsolescence
For the 6AV2124-0JC01-0AX0, Siemens currently lists the product status PM400: Product phase-out announcement, with an effective date of 31 January 2026. For operators, this means that the panel is still clearly identifiable and widely available through service and spare-parts channels, but from a life-cycle perspective it is already moving towards obsolescence management. Siemens also identifies 6AV2128-3KB06-0AX1 as a successor reference. In Siemens documentation, this device is positioned as the MTP1000 Unified Comfort within modernisation concepts for the TP900 Comfort. For purchasers and decision-makers, this is important because successor selection involves not only availability but also project migration, communication interfaces and the overall modernisation effort.
Available EICHLER services and when they are relevant
For the 6AV2124-0JC01-0AX0, EICHLER offers repair, replacement, used equipment and new equipment. In active production environments, this is particularly important because a 1:1 replacement or a professionally executed repair often restores availability more quickly than a complete modernisation project. The repair service includes technical cleaning, preventive maintenance, comprehensive functional testing and a minimum 24-month warranty; an optional test report is also available. This is especially relevant for maintenance teams when the existing panel cut-out, project status and communication setup are to remain unchanged. For purchasing departments and production managers, the combination of repair and replacement options helps reduce the risk of extended downtime, particularly when a product has already entered its phase-out stage. These services are intended for business customers.
| Attribute | Value |
|---|---|
| Product type designation | TP900 Comfort |
| Display | |
| Design of display | TFT |
| Screen diagonal | 9 in |
| Display width | 195 mm |
| Display height | 117 mm |
| Number of colors | 16 777 216 |
| Resolution (pixels) | |
| ● Horizontal image resolution | 800 pixel |
| ● Vertical image resolution | 480 pixel |
| Backlighting | |
| ● MTBF backlighting (at 25 °C) | 80 000 h |
| ● Backlight dimmable | Yes; 0-100 % |
| Control elements | |
| Keyboard fonts | |
| ● Function keys | |
| — Number of function keys | 0 |
| — Number of function keys with LEDs | 0 |
| ● Keys with LED | No |
| ● System keys | No |
| ● Numeric keyboard | Yes; Onscreen keyboard |
| ● alphanumeric keyboard | Yes; Onscreen keyboard |
| Touch operation | |
| ● Design as touch screen | Yes; Analog-resistive |
| Expansions for operator control of the process | |
| ● DP direct LEDs (LEDs as S7 output I/O) | |
| — F1...Fx | 0 |
| ● Direct keys (keys as S7 input I/O) | |
| — F1...Fx | 0 |
| ● Direct keys (touch buttons as S7 input I/O) | 40 |
| Installation type/mounting | |
| Mounting position | vertical |
| Wall mounting/direct mounting | No |
| Mounting in portrait format possible | Yes |
| Mounting in landscape format possible | Yes |
| maximum permissible angle of inclination without external ventilation | 35° |
| Supply voltage | |
| Type of supply voltage | DC |
| Rated value (DC) | 24 V |
| permissible range, lower limit (DC) | 19.2 V |
| permissible range, upper limit (DC) | 28.8 V |
| Input current | |
| Current consumption (rated value) | 0.75 A |
| Starting current inrush I²t | 0.5 A²·s |
| Power | |
| Active power input, typ. | 18 W |
| Processor | |
| Processor type | X86 |
| Memory | |
| Flash | Yes |
| RAM | Yes |
| Memory available for user data | 12 Mbyte |
| Type of output | |
| Info LED | No |
| Power LED | No |
| Error LED | No |
| Acoustics | |
| ● Buzzer | No |
| ● Speaker | Yes |
| Time of day | |
| Clock | |
| ● Hardware clock (real-time) | Yes |
| ● Software clock | Yes |
| ● retentive | Yes; Back-up duration typically 6 weeks |
| ● synchronizable | Yes |
| Interfaces | |
| Number of industrial Ethernet interfaces | 1; 2 ports (switch) |
| Number of RS 485 interfaces | 1; RS 422 / 485 combined |
| Number of RS 422 interfaces | 0; together with RS 485 |
| Number of RS 232 interfaces | 0 |
| Number of USB interfaces | 2; USB 2.0 |
| ● USB Mini B | 1; 5-pole |
| Number of 20 mA interfaces (TTY) | 0 |
| Number of parallel interfaces | 0 |
| Number of other interfaces | 0 |
| Number of SD card slots | 2 |
| With software interfaces | No |
| Industrial Ethernet | |
| ● Industrial Ethernet status LED | 2 |
| ● Number of ports of the integrated switch | 2 |
| Protocols | |
| PROFINET | Yes |
| Supports protocol for PROFINET IO | Yes |
| IRT | Yes; As of WinCC V12 |
| PROFIBUS | Yes |
| EtherNet/IP | Yes |
| MPI | Yes |
| Protocols (Ethernet) | |
| ● TCP/IP | Yes |
| ● DHCP | Yes |
| ● SNMP | Yes |
| ● DCP | Yes |
| ● LLDP | Yes |
| WEB characteristics | |
| ● HTTP | Yes |
| ● HTTPS | Yes |
| ● HTML | Yes |
| ● XML | Yes |
| ● CSS | Yes |
| ● Active X | Yes |
| ● JavaScript | Yes |
| ● Java VM | No |
| Redundancy mode | |
| Media redundancy | |
| — MRP | Yes; As of WinCC V12 |
| Further protocols | |
| ● CAN | No |
| ● MODBUS | Yes |
| Interrupts/diagnostics/status information | |
| Diagnoses | |
| ● Diagnostic information readable | Yes; S7 controller |
| EMC | |
| Emission of radio interference acc. to EN 55 011 | |
| ● Limit class A, for use in industrial areas | Yes |
| ● Limit class B, for use in residential areas | No |
| Degree and class of protection | |
| IP (at the front) | IP65 |
| IP (rear) | IP20 |
| NEMA (front) | |
| ● Enclosure Type 4 at the front | Yes |
| ● Enclosure Type 4x at the front | Yes |
| Standards, approvals, certificates | |
| CE mark | Yes |
| cULus | Yes |
| RCM (formerly C-TICK) | Yes |
| KC approval | Yes |
| Ecological footprint | |
| ● environmental product declaration | Yes |
| Global warming potential | |
| — global warming potential, (total) [CO2 eq] | 254 kg |
| — global warming potential, (during production) [CO2 eq] | 61.5 kg |
| — global warming potential, (during operation) [CO2 eq] | 194 kg |
| — global warming potential, (after end of life cycle) [CO2 eq] | -1.87 kg |
| Use in hazardous areas | |
| ● ATEX Zone 2 | Yes |
| ● ATEX Zone 22 | Yes |
| ● IECEx Zone 2 | Yes |
| ● IECEx Zone 22 | Yes |
| ● cULus Class I Zone 1 | No |
| ● cULus Class I Zone 2, Division 2 | Yes |
| ● FM Class I Division 2 | Yes |
| Marine approval | |
| ● Germanischer Lloyd (GL) | Yes |
| ● American Bureau of Shipping (ABS) | Yes |
| ● Bureau Veritas (BV) | Yes |
| ● Det Norske Veritas (DNV) | Yes |
| ● Lloyds Register of Shipping (LRS) | Yes |
| ● Nippon Kaiji Kyokai (Class NK) | Yes |
| ● Polski Rejestr Statkow (PRS) | No |
| Ambient conditions | |
| Suited for indoor use | Yes |
| Suited for outdoor use | No |
| Ambient temperature during operation | |
| Operation (vertical installation) | |
| — For vertical installation, min. | 0 °C |
| — For vertical installation, max. | 50 °C; (55 °C, see entry ID: 64847814) |
| Operation (max. tilt angle) | |
| — At maximum tilt angle, min. | 0 °C |
| — At maximum tilt angle, max. | 40 °C |
| Operation (vertical installation, portrait format) | |
| — For vertical installation, min. | 0 °C |
| — For vertical installation, max. | 40 °C |
| Operation (max. tilt angle, portrait format) | |
| — At maximum tilt angle, min. | 0 °C |
| — At maximum tilt angle, max. | 35 °C |
| Ambient temperature during storage/transportation | |
| ● min. | -20 °C |
| ● max. | 60 °C |
| Relative humidity | |
| ● Operation, max. | 90 %; no condensation |
| Operating systems | |
| proprietary | No |
| pre-installed operating system | |
| ● Windows CE | Yes |
| Configuration | |
| Message indicator | Yes |
| Alarm system (incl. buffer and acknowledgment) | Yes |
| Process value display (output) | Yes |
| Process value default (input) possible | Yes |
| Recipe management | Yes |
| Configuration software | |
| ● STEP 7 Basic (TIA Portal) | No |
| ● STEP 7 Professional (TIA Portal) | No |
| ● WinCC flexible Compact | No |
| ● WinCC flexible Standard | No |
| ● WinCC flexible Advanced | No |
| ● WinCC Basic (TIA Portal) | No |
| ● WinCC Comfort (TIA Portal) | Yes; from V11 |
| ● WinCC Advanced (TIA Portal) | Yes; from V11 |
| ● WinCC Professional (TIA Portal) | Yes; from V11 |
| Languages | |
| Online languages | |
| ● Number of online/runtime languages | 32 |
| Project languages | |
| ● Languages per project | 32 |
| Functionality under WinCC (TIA Portal) | |
| Libraries | Yes |
| Applications/options | |
| ● Web browser | Yes |
| ● Pocket Word | Yes |
| ● Pocket Excel | Yes |
| ● PDF Viewer | Yes |
| ● Media Player | Yes |
| ● SIMATIC WinCC Sm@rtServer | Yes |
| ● SIMATIC WinCC Audit | Yes |
| Number of Visual Basic Scripts | Yes |
| Task planner | |
| ● time-controlled | Yes |
| ● task-controlled | Yes |
| Help system | |
| ● Number of characters per info text | 70 |
| Message system | |
| ● Number of alarm classes | 32 |
| ● Bit messages | Yes |
| — Number of bit messages | 4 000 |
| ● Analog messages | Yes |
| — Number of analog messages | 200 |
| ● S7 alarm number procedure | Yes |
| ● System messages HMI | Yes |
| ● System event, more (SIMATIC S7, SINUMERIK, SIMOTION, ... ) | Yes |
| ● Number of characters per message | 80 |
| ● Number of process values per message | 8 |
| ● Acknowledgment groups | Yes |
| ● Message indicator | Yes |
| ● Message buffer | |
| — Number of entries | 1 024 |
| — Circulating buffer | Yes |
| — retentive | Yes |
| — maintenance-free | Yes |
| Recipe management | |
| ● Number of recipes | 300 |
| ● Data records per recipe | 500 |
| ● Entries per data record | 1 000 |
| ● Size of internal recipe memory | 2 Mbyte |
| ● Recipe memory expandable | Yes |
| Variables | |
| ● Number of variables per device | 2 048 |
| ● Number of variables per screen | 400 |
| ● Limit values | Yes |
| ● Multiplexing | Yes |
| ● Structures | Yes |
| ● Arrays | Yes |
| Images | |
| ● Number of configurable images | 500 |
| ● Permanent window/default | Yes |
| ● Global image | Yes |
| ● Pop-up images | Yes |
| ● Slide-in images | Yes |
| ● Image selection by PLC | Yes |
| ● Image number in the PLC | Yes |
| Image objects | |
| ● Number of objects per image | 400 |
| ● Text fields | Yes |
| ● I/O fields | Yes |
| ● Graphic I/O fields (graphics list) | Yes |
| ● Symbolic I/O fields (text list) | Yes |
| ● Date/time fields | Yes |
| ● Switches | Yes |
| ● Buttons | Yes |
| ● Graphic display | Yes |
| ● Icons | Yes |
| ● Geometric objects | Yes |
| Complex image objects | |
| ● Number of complex objects per screen | 20 |
| ● Alarm view | Yes |
| ● Trend view | Yes |
| ● User view | Yes |
| ● Status/control | Yes |
| ● Sm@rtClient view | Yes |
| ● Recipe view | Yes |
| ● f(x) trend view | Yes |
| ● System diagnostics view | Yes |
| ● Media Player | Yes |
| ● HTML browser | Yes |
| ● PDF display | Yes |
| ● IP camera display | Yes |
| ● Bar graphs | Yes |
| ● Sliders | Yes |
| ● Pointer instruments | Yes |
| ● Analog/digital clock | Yes |
| Lists | |
| ● Number of text lists per project | 500 |
| ● Number of entries per text list | 500 |
| ● Number of graphics lists per project | 500 |
| ● Number of entries per graphics list | 500 |
| Archiving | |
| ● Number of archives per device | 50 |
| ● Number of entries per archive | 20 000 |
| ● Message archive | Yes |
| ● Process value archive | Yes |
| ● Archiving methods | |
| — Sequential archive | Yes |
| — Short-term archive | Yes |
| ● Memory location | |
| — Memory card | Yes |
| — USB memory | Yes |
| — Ethernet | Yes |
| ● Data storage format | |
| — CSV | Yes |
| — TXT | Yes |
| — RDB | Yes |
| Security | |
| ● Number of user groups | 50 |
| ● Number of user rights | 32 |
| ● Number of users | 50 |
| ● Password export/import | Yes |
| ● SIMATIC Logon | Yes |
| Logging through printer | |
| ● Alarms | Yes |
| ● Report (shift log) | Yes |
| ● Hardcopy | Yes |
| ● Electronic print to file | Yes; PDF, HTML |
| Character sets | |
| ● Keyboard fonts | |
| — US English | Yes |
| Transfer (upload/download) | |
| ● MPI/PROFIBUS DP | Yes |
| ● USB | Yes |
| ● Ethernet | Yes |
| ● using external storage medium | Yes |
| Process coupling | |
| ● S7-1200 | Yes |
| ● S7-1500 | Yes |
| ● S7-200 | Yes |
| ● S7-300/400 | Yes |
| ● LOGO! | Yes |
| ● WinAC | Yes |
| ● SINUMERIK | Yes; with SINUMERIK option package |
| ● SIMOTION | Yes |
| ● Allen Bradley (EtherNet/IP) | Yes |
| ● Allen Bradley (DF1) | Yes |
| ● Mitsubishi (MC TCP/IP) | Yes |
| ● Mitsubishi (FX) | Yes |
| ● OMRON (FINS TCP) | No |
| ● OMRON (LINK/Multilink) | Yes |
| ● Modicon (Modbus TCP/IP) | Yes |
| ● Modicon (Modbus) | Yes |
| ● OPC UA Client | Yes |
| ● OPC UA Server | Yes |
| Service tools/configuration aids | |
| ● Backup/Restore manually | Yes |
| ● Backup/Restore automatically | Yes |
| ● Simulation | Yes |
| ● Device switchover | Yes |
| Peripherals/Options | |
| Printer | Yes |
| SIMATIC HMI MM memory card: Multi Media Card | Yes; Up to 128 MB |
| SIMATIC HMI SD memory card: Secure Digital memory card | Yes; Up to 2 GB |
| SIMATIC HMI CF memory card Compact Flash Card | No |
| USB memory | Yes |
| SIMATIC IPC USB Flashdrive (USB stick) | Yes; Up to 16 GB |
| SIMATIC HMI USB stick | Yes; Up to 8 GB |
| Network camera | Yes |
| Mechanics/material | |
| Enclosure material (front) | |
| ● Plastic | No |
| ● Aluminum | Yes |
| ● Stainless steel | No |
| Dimensions | |
| Width of the housing front | 274 mm |
| Height of housing front | 190 mm |
| Mounting cutout, width | 251 mm |
| Mounting cutout, height | 166 mm |
| mounting depth | 62.7 mm |
| Weights | |
| Weight (without packaging) | 1.9 kg |
| Weight (with packaging) | 2.6 kg |
| Fault description | Possible solution |
|---|---|
| Why does ProSave or TIA not find my TP900 Comfort even though a ping works? | First check the transfer settings in the panel and the transfer channel actually selected. In many cases, a different transfer path is configured in the operator panel than in the engineering software. Also place the panel explicitly into transfer mode, verify the IP address, subnet and duplicate IP addresses, and, if necessary, test Ethernet instead of PN/IE or vice versa. |
| Why is the download aborted due to a transfer error? | Check whether the correct panel type is actually configured in the project and whether the HMI image file matching the TIA/WinCC version in use is available. If there is a version conflict between the project version and the panel image, the transfer will be aborted. In this case, first perform the appropriate OS/image update and then restart the project transfer. |
| Why does the touch screen respond inaccurately or stop responding correctly? | On the TP900 Comfort, the touch screen can be recalibrated via Control Panel > OP > Touch. After OS-related work or if unusual operating behaviour occurs, the calibration should be checked. If operation remains inaccurate, inspect the front panel for mechanical damage, as Siemens points out that pointed or hard objects can damage the touch surface and may ultimately cause complete failure. |
| Why does restore not work on the replacement panel? | Backup and restore functions on Comfort Panels are intended for the original device or a panel of the same type. Therefore, use an identical or equivalent panel model. Only devices of the same type reliably support restoring a backup; if the device type or hardware variant differs, the automatic restoration process will typically fail. |
| Why can I not access the Control Panel or reset the panel to factory settings? | Check whether password protection or SecureMode is active. Siemens states that enabling password protection automatically activates SecureMode. In this case, local changes in the Control Panel are only possible with the correct password. If the password is unknown, a simple local reset is generally not possible and the documented service procedure must be followed. |
Is the 6AV2124-0JC01-0AX0 already discontinued?
Siemens currently lists the device with the life-cycle status PM400: Product phase-out announcement. Siemens specifies 31 January 2026 as the effective date. For procurement, this does not automatically mean that no material is available anymore, but supply should be planned proactively. It is precisely during this phase that repairs, replacement units, used assemblies and clearly defined spare-part strategies become particularly important in order to avoid unplanned system downtime.
Which successor is specified for the 6AV2124-0JC01-0AX0?
Siemens identifies 6AV2128-3KB06-0AX1 as the successor reference for the TP900 Comfort. In Siemens modernisation documentation, this device is positioned as the MTP1000 Unified Comfort within the successor context of the TP900 Comfort. For migration projects, it is important not to focus solely on the article number, but also to evaluate project migration, the visualisation concept and the mechanical integration. A successor is therefore not automatically a completely seamless 1:1 replacement but rather part of a structured modernisation assessment.
Which software can be used to configure the TP900 Comfort?
The 6AV2124-0JC01-0AX0 can be configured from WinCC Comfort V11 onwards. This information is particularly relevant for maintenance and engineering teams when an existing project needs to be reloaded, extended or checked for compatibility. It should also be noted that the panel is based on Windows CE 6.0. For operators of older machinery, this combination is typical, but it also indicates that existing installations should be carefully assessed when modifications or cybersecurity considerations are involved.
Which interfaces are particularly important when replacing the panel?
For replacement projects in existing installations, the communication and power-supply specifications are especially important. The panel provides PROFINET via Industrial Ethernet with an integrated 2-port switch, MPI/PROFIBUS-DP via the combined RS422/485 interface, as well as 2 × USB 2.0 and 2 SD card slots. The device operates on 24 V DC, with a permissible range of 19.2 to 28.8 V. This combination makes the panel particularly attractive in systems where legacy fieldbus structures and newer Ethernet-based communication coexist.
Can I restore a backup to another panel?
Yes, but only under specific conditions. Siemens describes the backup/restore and automatic service concept in such a way that restoration is intended for the original device or for an operator panel of the same type. For operators, this is a critical point: a backup is extremely valuable, but it does not eliminate the need to verify exact hardware compatibility. Anyone aiming to minimise downtime should therefore plan for an identical replacement panel or an appropriate spare-part strategy.
Can I retrieve the original project from a running TP900 Comfort?
A backup secures the device data required for operation, but it is not the same as a fully editable engineering project. Siemens points out that HMI runtime data cannot simply be loaded back into a TIA Portal or WinCC project and then edited normally. For modifications, expansions or migrations, the original project remains essential. Nevertheless, backup/restore remains indispensable for ensuring a fast recovery in the event of a fault.
When is a repair more appropriate than a complete replacement?
Repair is particularly advantageous when the panel cut-out, wiring, existing WinCC project and machine approval should remain unchanged. For this panel, EICHLER offers repairs including technical cleaning, preventive maintenance, comprehensive functional testing and a minimum 24-month warranty. This is especially attractive for existing production systems because the current integration remains intact and recommissioning can often be organised more quickly than a complete modernisation project. In addition, replacement, used-equipment and new-equipment options are available.